Skip to content

Quality Control

Valve Quality Control: Testing, Traceability & Records

VALMORA helps industrial valve buyers define inspection and test requirements for the valves they intend to order. Start with the product specification and acceptance criteria, then agree which material, test and release records must accompany that supply.

For gate, ball, butterfly and other valve types, the required tests and documentation depend on design, service and the purchase order—not a single universal test claim.

Large valve in a pressure-test rig shown in Lianggong supplier catalog; not a VALMORA order test result

QUALITY REQUIREMENTS

Make the quality requirements part of the valve RFQ

A test certificate is useful only if it corresponds to the offered valve and the agreed acceptance basis. Define the following three items before comparing quotations.

Identify the supplied configuration

State valve type, size, pressure class or rating, body and trim materials, seat, ends, actuator and any project tag. A family-level catalog description cannot define the test scope of every configuration.

Specify tests and acceptance

Name the applicable product and test standard, edition where required, pressure-boundary and seat tests, leakage acceptance, test medium and any additional functional checks.

Agree who records and witnesses

Identify the inspection stage, record format and purchaser or third-party witness points, if required. A photo of the equipment is not a signed result for a particular valve.

ORDER QUALITY PLAN

Which inspections should be in the order?

Use a purchase-order inspection and test plan (ITP) to match each required check to an acceptance criterion and deliverable. The activities below are examples of what to specify—not a statement that every valve receives every test.

Inspection stageSpecify in the RFQ / ITPEvidence to request
Materials and identityGrade, heat/lot and critical parts to traceApplicable material records linked to delivered item or lot
Dimensions and assemblyDrawing revision, key dimensions, marking and actuator scopeAgreed dimensional or assembly inspection record
Pressure and functionApplicable shell/seat checks, test method and acceptance; actuator/function tests where relevantValve- or batch-identified test report, with conditions and outcome
Final inspection and releaseCoating/condition, tags, protection, deviations and document listRelease record and agreed shipment documentation

TEST STANDARD APPLICABILITY

Choose a test basis that actually covers the valve

The design standard, the product category and the purchase specification determine which production tests apply. Quoting a standard number alone does not define the acceptance criteria for an unidentified valve.

API 598: common isolation valves

API 598 covers inspection and pressure testing for specified gate, globe, plug, ball, check and butterfly valves, including different seat constructions. Confirm that the offered design and product standard call for it, then specify any purchaser-selected supplemental tests.

ISO 5208 / EN 12266-1: metallic valves

These address pressure and closure testing of industrial metallic valves. Apply them together with the relevant product standard; product-specific requirements can take precedence. EN 12266-1 does not cover safety devices.

Control, safety and specialty valves

A control valve may need actuator and travel checks or a specified seat-leakage performance test. Safety and relief valves require their own applicable inspection and setting requirements. Do not transfer an isolation-valve protocol to these products without confirming applicability.

MATERIAL IDENTIFICATION

Link material documents to the parts being supplied

A material certificate can support grade and inspection results for an identified material lot; it is not a certificate that the assembled valve passed its pressure test. Agree the required traceability level and documentation type before the order.

INSPECTION & WITNESS POINTS

Decide when the buyer needs to be present

Purchaser inspection, hold points and third-party witnessing are order conditions, not automatic features of every shipment. Agree feasibility, location, notice and access before production scheduling.

1. Set the inspection plan

Identify mandatory checks, applicable procedures, inspection stage and whether each point is review, witness or hold.

2. Schedule notice

Agree who will be notified, at what stage and with what lead time; do not assume a witness can attend without scheduling.

3. Confirm test conditions

Review test medium, pressure, duration and leakage acceptance against the agreed applicable specification; no single values fit every valve.

4. Release the hold point

Record witnessed results and any accepted deviations before release, according to the purchase-order inspection arrangement.

DOCUMENT PACKAGE

What belongs in a reviewable valve quality file?

Match the document list to the order and identify which items are required at quotation, before production, before dispatch or with shipment. Availability and issue format must be confirmed for the exact supply.

Approved technical identification

Agreed datasheet and drawing revisions, product description, valve tag or line number and applicable material/pressure-rating information.

Material and inspection records

Specified material reports, heat/lot mapping, dimensional records and any required examination results, linked to the relevant component or inspection lot.

Test results and acceptance

A report should identify the test subject, procedure, pressure or test conditions where relevant, result, acceptance basis and authorizing record—not merely state “tested.”

Release and exceptions

Include the agreed final inspection status, approved concessions or nonconformances if any, and a document register matching the latest approved revisions.

WHEN RESULTS DO NOT MATCH

Handle deviations before shipment, not in the catalog copy

If a material report, dimension or test result falls outside the agreed basis, identify the affected valve and isolate the issue from unrelated orders. Shipment disposition should follow the contractually agreed approval process.

Identify the affected items

Record the item/tag/lot, failed check, required value or acceptance criterion, actual result and drawing or procedure revision.

Agree a corrective route

Define rework, retest, replacement or a proposed concession as appropriate. A supplier proposal is not automatically a purchaser approval.

Close with traceable evidence

Retain the follow-up test report or written disposition, approval where required and updated release/document status.

COMMON PROCUREMENT QUESTIONS

Three distinctions that prevent document surprises

These questions clarify what an order-specific quality request should establish, without implying that a supplier catalog photo or a generic certificate is product acceptance evidence.

Is a photo of pressure testing enough for acceptance?

No. Ask for an identified valve or lot, the required test procedure, conditions, acceptance limit and authorized results record. A photo is supplementary context at most.

Is an EN 10204 3.1 certificate a finished-valve test report?

Not by itself. The document type describes specific product/material inspection documentation and its validation. A valve pressure test needs its own applicable evidence unless that requirement is explicitly covered by the agreed document package.

Can I request third-party witnessing?

Yes, request it in the inquiry with the valve identity, inspection points, inspector role and required notice. Availability, cost, access and scope must be agreed before the order is placed.

WHAT THE IMAGES DOCUMENT

Visible supplier facilities are context, not an order result

The source catalog identifies test and inspection areas and shows a large-scale valve pressure-test setup, material checks and process-inspection scenes. VALMORA uses this supplier documentation to discuss inspection options for relevant supply. The photos do not establish facility ownership, current capacity, accredited laboratory status or an individual valve’s passed tests.

Large valve test setup

The catalog labels a large-scale pressure-test station (physical p. 22). Its pictured size label describes the supplier photograph, not a size or test capability promised for this RFQ.

Inspection and measurement

Physical p. 24 shows a testing and inspection center with metrology and material-check images. Request the actual procedures and reports needed for your order.

Process and functional-test scenes

Physical p. 25 shows process checks and valve-related test equipment. Product-specific acceptance still depends on the agreed plan and records.

Image source: Lianggong Valve Product Catalog EN, physical pages 22, 24 and 25 (supplier publication). Photos show supplier-catalog context, not independent certification of VALMORA facilities or delivery.

ORDER-SPECIFIC QUALITY SUPPORT

Ask for the inspections and records your valve order needs

Send the valve type or datasheet, size/rating, materials, service conditions, required standard/edition, test acceptance criteria and document list. Add any purchaser hold points or third-party witness request so feasibility and scope can be reviewed before quotation or order confirmation.