Skip to content

Pipeline strainer · catalog-identified design

Stainless Steel Basket Strainer

Stainless steel basket strainer shown in the source catalog, with a bolted top cover and flanged connections

A stainless steel basket strainer is a pipeline screening device that retains solid debris in a basket or screen element. For a purchasable configuration, the opening size, flow and pressure-drop limits, material schedule, and basket removal space must be checked together. The catalog identifies this product but does not publish those design values for this item.

Use the catalog image as a visual reference—not as a dimensioned drawing or proof of a particular stainless grade. Request an offered datasheet and arrangement drawing for the intended duty.

What is being specified

Housing, basket and screen are separate decisions

The source catalog labels the assembled item as a stainless steel basket strainer. It does not identify the grade or construction of every wetted component. A quotation should therefore separate the pressure-retaining housing from the removable straining element and any cover seal.

Housing and cover

Confirm the body and cover grades, gasket material, design pressure/temperature and connection details. An external photo cannot establish a pressure rating or sealing arrangement.

Basket and screen

Specify a removable element, the required perforation or mesh opening, support construction and basket material. “Stainless steel” in the product name alone does not establish a basket alloy.

Documents to obtain

Ask for the offered assembly drawing, basket details and parts/material list. Use the source catalog to identify the item—not to derive dimensions that it does not show.

Catalog facts

What the catalog actually states

The five facts below are traceable to the printed label or heading. Operating ratings and an exact part-level bill of materials are not provided on that page.

FieldCatalog informationScope of evidence
Product familyStrainerProduct name and category
Construction labelBasket strainerDesign name, not full construction detail
Material descriptorStainless steelGrade and component allocation not stated
Catalog sectionIntegrated Product SeriesPrinted section heading
Source locationPDF page 113 (printed page 215)Catalog reference, not an approved order drawing

Not specified by this catalog entry: nominal size, pressure class, pressure–temperature limits, perforation or mesh construction, flow/Cv, pressure-drop curve, precise wetted material grades, cover sealing arrangement, connection dimensions and test records. These must come from the specific offer and supporting documents.

Construction boundary

Stainless steel is not a complete material specification

A stainless designation in a catalog heading does not prove 304, 316, 316L or any other grade, and it does not prove that the basket, screen, fasteners and seals match the housing material. Corrosion and allowable pressure also depend on the actual fluid, temperature and design.

Materials to list separately

Limits to substantiate

Basket and hydraulic selection

Choose an opening that protects equipment without choking flow

Start with the largest particle that downstream equipment can tolerate and the debris actually present—not with a mesh number from another installation. Smaller openings can retain finer solids but usually increase resistance and cleaning frequency. The basket design must also have enough effective open area and strength for clean and loaded operation.

Illustrative geometry, not a VALMORA product specification: a nominal 40-mesh square weave has 40 openings per inch, giving 25.4 ÷ 40 = 0.635 mm center-to-center pitch. If the wire diameter is 0.25 mm, the ideal clear opening is about 0.385 mm and its theoretical geometric open fraction is about 37%. A different wire diameter changes both values; basket supports, tolerances, particle shape and clogging further affect actual performance. Therefore “40 mesh” alone does not certify 385 µm retention or a pressure-drop result.

Particle retention

Define the solids type, shape, size distribution and maximum particle permitted downstream. Select an opening on that basis; a strainer is not automatically a fine or absolute-rated filter.

Mesh or perforated basket

For woven mesh, request mesh count, wire diameter and measured clear aperture. For perforated plate, request hole diameter, pitch/pattern and thickness. State the support structure and effective open area for the complete element.

Flow and pressure loss

Provide normal/maximum flow, density and viscosity at operating temperature, and the available clean-strainer pressure-drop budget. Request a clean-element curve or Cv/Kv for the actual offered assembly; do not extrapolate a competitor’s water curve to a viscous liquid.

Solids loading and cleaning

State expected solids concentration, peak debris events and desired service interval. Request the allowable dirty differential pressure and basket strength; set cleaning or inspection based on the design and observed rise in ΔP, not a universal guessed threshold.

Mechanical interfaces

Provide line size, mating end type, piping schedule/standard, pressure and temperature, corrosion exposure, and available installation space. Ask for certified interface dimensions, basket lift clearance and any drain/vent arrangement on the offered drawing.

Layout and maintenance

Check basket access before freezing the pipe layout

A basket that cannot be safely withdrawn becomes a maintenance problem even if the nominal line size fits. Use the offered drawing to check the actual flow arrow, body orientation, removable cover and basket lift path. Do not assume online cleaning, a duplex changeover, a bypass or a drain valve is included.

Orientation and flow direction

Confirm the permitted installation orientation against the supplied drawing. The appearance of a vertical collection chamber does not establish that every vertical or horizontal pipe arrangement is acceptable.

Cover and lifting clearance

Reserve room above/around the cover for fastener access, full basket extraction and safe handling of retained solids. Verify the cover opening and actual basket length rather than estimating clearance from the photo.

Isolation and safe cleaning

Define how the section is isolated, depressurized, drained and returned to service for basket cleaning. Request confirmation of any vent, drain or monitoring connections and of the allowable basket differential pressure.

Technical RFQ

Request a stainless steel basket strainer quotation

Share the operating duty and the basket specification you need. If the aperture or maximum allowable pressure loss is not yet known, identify the downstream equipment and the constraints so the proposed design can be evaluated. Request the actual basket drawing, pressure-drop basis and part-level material schedule with the quotation.

Fields marked * are required.