Skip to content

CATALOG-LISTED PRODUCT

Water Pipeline Strainer

Water Pipeline Strainer catalog photograph showing a blue flanged body with an angled bolted cover

The 2026 English product catalog lists this item as Water Pipeline Strainer under the printed section heading Hydraulic Control Valve Series. The matched photograph shows a blue flanged body with an angled chamber and bolted cover. The reviewed entry identifies the item but does not provide an order-ready specification.

CATALOG IDENTITY

What this catalog record confirms

Use this page for one catalog-listed item. The parent Strainers page handles category-level selection and comparison; this record does not inherit specifications from other strainer entries.

Catalog product name

Water Pipeline Strainer — the exact product label shown above the matched photograph.

Printed catalog section

Hydraulic Control Valve Series — the printed page heading only, not proof of a hydraulic pilot, actuator or control function.

Source location

English product catalog, PDF page 103 (printed page 196); the label and matched photograph appear on this page.

SOURCE RECORD

Catalog evidence at a glance

The fields below are transcribed from the reviewed source page. Product performance and orderable configuration must be confirmed against the specific offer.

Catalog fieldSource recordWhat it establishes
Product labelWater Pipeline StrainerExact printed product name
Printed section headingHydraulic Control Valve SeriesCatalog page classification only; not a verified product mechanism
Source locationPDF page 103 / printed page 196Location of the product label and photograph
Matched imageCatalog photograph on page 103Visual match to the Water Pipeline Strainer label

Use this as a catalog identity record. Request the exact datasheet and approved drawing before technical selection or purchase.

IMAGE & CONSTRUCTION OBSERVATION

What can be seen in the catalog photograph

The matched photograph helps identify the catalog item. It is a visual reference, not a section drawing or a complete construction record.

Visible in the photograph

Not established by the reviewed source

PRODUCT-SPECIFIC CONFIGURATION

What must be confirmed before this item can be selected

The catalog entry names the item but supplies no orderable size, screen or rating. Use the inputs below to check whether the offered configuration matches the pipeline and the equipment it must protect.

Screen and retention

Identify the downstream equipment and the particle size it can tolerate. State the required clear opening or perforation. If woven mesh is specified, include the clear opening and wire diameter rather than relying on mesh count alone; also confirm screen construction and effective open area. Do not infer mesh, micron rating or retention efficiency from the product name or photograph.

Flow and differential pressure

Provide minimum, normal and maximum flow, water temperature and relevant density or viscosity data. Request pressure-drop data for the exact offered size and screen in the clean condition and at the agreed loading case, then confirm the element’s allowable differential pressure. Set the project limit against system or pump margin and the screen limit, not a generic cleaning threshold.

Water and materials

Describe the actual water source and chemistry, suspended-solids concentration, minimum / normal / maximum temperature, corrosion or erosion conditions, and ambient exposure where it affects coatings or corrosion allowance. Confirm body, screen, gasket and fastener materials against the offered datasheet; the catalog entry does not identify material grades.

Pressure and piping interface

Provide design and operating pressure and temperature, surge or vacuum cases, DN/NPS and pipe schedule. State the end-connection type and mating flange standard, rating, facing and drilling; confirm face-to-face dimensions and any applicable project specification or edition on the approved drawing.

Cleaning and maintenance

State whether the line can be isolated for cleaning, the expected solids loading and the required cleaning frequency. Confirm cover access, screen-removal clearance, any drain, blowdown or backwash feature, drain routing, isolation points and safe depressurization requirements.

SUPPLIER DOCUMENT REVIEW

Match the documents to the quoted configuration

A catalog photograph cannot close the technical review. Request documents that identify the exact offered size, screen and connection.

Dimensional / general arrangement drawing

Verify overall and face-to-face dimensions, end connection, flange drilling and facing, flow direction, installation orientation, pipe support or loads, cover access and screen-removal clearance.

Datasheet and screen details

Confirm the offered body, screen and seal materials, design and operating limits, screen opening and construction, effective open area and pressure-drop data.

Inspection and test records

Specify the material certificates, pressure or leakage test, inspection, marking and third-party witness records required by the project. Ask the supplier to confirm which records are available for the quoted configuration.

BUYER QUESTIONS

Water Pipeline Strainer: key questions

These answers separate the catalog identity from the details still needed for selection.

Does the catalog identify this as a Y-type strainer?

No formal design type is stated on the reviewed entry. The photograph shows an angled chamber and bolted cover, but it does not show the internal screen or establish a formal Y-type construction. Confirm the design on the offered drawing.

Does the name confirm compatibility with every type of water?

No. Water Pipeline Strainer is the catalog name, not a material-compatibility or operating-limit statement. Submit the actual water chemistry, suspended solids, temperature and pressure, then verify the offered body, screen and gasket materials against that duty.

Does the Hydraulic Control Valve Series heading confirm hydraulic actuation?

No. It is the printed catalog section heading. The reviewed entry does not identify a hydraulic pilot, actuator, control circuit or powered cleaning system. Confirm any such equipment separately if the project requires it.

Can this item be cleaned without interrupting flow?

The reviewed entry does not identify a blowdown, backwash, duplex or automatic-cleaning arrangement. If the line cannot be shut down, state that as a design requirement and request a drawing and maintenance description that show how continuous service is maintained.

TECHNICAL INQUIRY

Request a Water Pipeline Strainer configuration review

Reference the catalog entry and send the operating and piping data below. The offered screen, materials, rating, connection and cleaning arrangement must be confirmed before the configuration can be treated as order-ready.

Fields marked * are required.