Catalog-listed check valve
Wafer Forged Steel Check Valve
The original product catalog labels this item Wafer Forged Steel Check Valve and shows the matching product photograph on physical page 82. Its internal closure design, exact material grades, mating dimensions and pressure-temperature limits are not specified by that catalog entry. Use the drawing and service data from an offered configuration—not the photograph—to release a purchase.
- Product family: check (non-return) valve
- End-form descriptor: wafer
- Material descriptor: forged steel (grade not documented)
- Exact configuration: subject to drawing and datasheet review
Source identity
What the product catalog actually shows
The original catalog gives a name and picture, not an orderable specification sheet. The terms below are descriptors in the printed label; no nominal size range, material grade, pressure class, internal mechanism, testing standard or certified performance is established for this product.
| Catalog evidence | Documented identity | Limit of the evidence |
|---|---|---|
| Product name | Wafer Forged Steel Check Valve | Name only; no unique model code |
| Valve family | Check Valve Series | Non-return function; closure mechanism unspecified |
| Construction descriptors | Wafer; forged steel | No flange dimensions, part grades or bill of materials |
| Product image | Matching catalog photograph, physical page 82 | Appearance only; not a sectional or dimensional drawing |
For a purchase specification: obtain the proposed valve drawing, material schedule and operating limits. The photograph is not a substitute for dimensional acceptance.
Configuration review
Five checks before specifying this wafer check valve
The first decision is whether a wafer connection and the offered internal check mechanism suit the line. The catalog label alone cannot settle either point. These checks distinguish what the buyer supplies from what the supplier must document.
Flange fit comes first
A wafer-style valve is evaluated for installation between mating pipe flanges. Compare the offered face-to-face length, outside diameter, sealing faces, centering/bolting arrangement and internal moving-element clearance with the line drawing. If the manufacturer cannot provide an approved outline drawing, do not accept it as a dimensional replacement.
Flow and closure behavior
Specify minimum, normal and peak flow; upstream/downstream pressures; and whether pumps cycle or reverse flow may occur. Ask for the proposed design’s opening differential (if applicable), pressure-loss data, closing characteristics and reverse-flow leakage limit. Do not infer a spring, swing disc, dual plate or silent closing action from this picture.
Pipe orientation and access
State whether the line is horizontal or vertical, its intended flow direction and nearby pumps, bends or other turbulence sources. Permitted mounting positions depend on the actual internal design; horizontal and vertical installation cannot be assumed interchangeable. Request the configuration-specific installation instructions.
Pressure, temperature and wetted parts
Supply design and operating pressure/temperature, media composition and relevant solids or corrosion exposure. Request body, closure member and seat/seal grades plus pressure-temperature limits for the offered build. Numbers visible on a catalog photograph are not a qualified rating or material certificate.
Documents needed for order release
Request a model-specific sectional drawing, dimensional drawing, material schedule, design/test standard and edition, defined seat leakage criteria and the inspection records required by the purchase order. Where opening behavior, flange fit or operating limits remain undocumented, keep the selection under technical review.
Matched source photograph
Catalog image: exterior view, not an installation drawing
This product photograph matches the item labelled Wafer Forged Steel Check Valve on original catalog physical page 82 (printed spread 153–154). It identifies the exterior appearance, but does not reveal the closure element, flow path, allowable flange interface or service limits.
Compare connection and duty
Other check-valve catalog routes
If the piping specification calls for a different end connection, material family or stated catalog designation, review the corresponding product identity separately. The pages below do not share proven dimensions or ratings with this wafer valve.
GB Standard H44W Check Valve
The catalog has a separate H44W entry shown with flanged ends. Start there when the requirement explicitly specifies that catalog designation, then verify the offered drawing and standards.
ASME Stainless Steel Check Valve
The separate catalog entry names a stainless-steel check valve. Its actual alloy grade, geometry and end compatibility must come from its own documents.
GB Vertical Lift Check Valve
The catalog distinguishes a vertical lift type. Its internal mechanism and permitted mounting arrangements must not be assigned to this wafer entry.
Technical RFQ
Request a documented wafer check valve configuration
Reference the Wafer Forged Steel Check Valve catalog item and describe the intended line. A technically comparable offer needs an identified design and an actual drawing; leave unknown product values open rather than copying figures from the catalog photo. Use the technical requirements or message field in the form below for the service details.
- Service: fluid, solids, normal/minimum/maximum flow, reverse-flow risk and pump cycling
- Piping: DN/NPS, mating flange standard/facing, line orientation and available clearance
- Operating case: design/normal pressure, temperature limits, allowable pressure loss and seat tightness
- Offered design: request internal mechanism, opening/closure data and permitted installation directions
- Procurement: quantity, required grades, approved drawings, tests, records and witness requirements