Skip to content

H44W · GB catalog check valve

GB Standard H44W Check Valve

Catalog photograph labeled GB Standard H44W Check Valve on the supplier PDF, physical page 82

The supplier catalog lists a GB Standard H44W Check Valve on physical PDF page 82 and shows its exterior. To request an interchangeable, service-ready valve, specify the pipeline conditions and obtain the drawing, material schedule, and applicable standard editions for the exact offered configuration.

Product reference

What the catalog documents

Use the printed label and matching photograph to identify the catalog item. The drawing and approved datasheet—not the model code or casting marks—must establish the supplied construction and interface.

Catalog designation

GB Standard H44W Check Valve is the exact English product label on PDF page 82.

Visible exterior

The matching catalog photo shows two flanged ends and a bolted top cover. Internal disc and hinge arrangement cannot be established from this exterior.

Original source

Supplier valve product catalog, physical PDF page 82, Check Valve Series. An adjacent product on the same page is labeled ASME Stainless Steel Check Valve and is not the H44W photograph.

Product information

H44W catalog facts and quotation inputs

The catalog establishes the product name and visible form. The following items must be matched to a configuration-specific quotation drawing before procurement or interchange.

FieldDocumented / availableEngineering status
Product identityGB Standard H44W Check ValvePrinted catalog label, PDF p. 82
Catalog categoryCheck Valve SeriesPrinted section heading
External connection appearanceFlanged ends visibleExact flange standard, facing, drilling and L dimension to be confirmed
External cover appearanceBolted top cover visibleSectional construction and closure mechanism to be confirmed
Design / inspection standardNot specified by the catalog labelRequest standard numbers and editions for offered unit
DN, pressure-temperature and materialsNot specified by the catalog labelRequest rated size, pressure-temperature limits and material schedule
Installation / testingNot specified by the catalog labelRequest orientation instructions, inspection and seat test criteria

For contractual use, request a dimensioned general-arrangement drawing and datasheet identified with the offered H44W configuration.

Important distinction

Is H44W the right check-valve configuration?

H44W is a useful catalog identifier, not a complete performance specification. A check valve selected for steady flow may behave poorly in low-flow or rapid pump-trip service; verify the closure mechanism and its operating range before selecting a replacement.

Start with the duty

Then verify the offer

Engineering selection

Information needed to specify an H44W check valve

Match these conditions to the offered manufacturer drawing rather than assuming that every valve using the H44W designation is interchangeable.

Flow and non-return duty

Describe the medium, normal and minimum flow, normal flow direction, and where reverse flow must stop. Low or turbulent flow can keep some check-valve discs from holding a stable open position; request the proposed valve’s operating limits.

Pressure and temperature

Provide design/operating pressure, normal and peak temperature, any transient or vacuum conditions, and required DN/pressure designation. The vendor must confirm the pressure-temperature rating for the actual body and seat materials.

Flanges and dimensions

State flange standard, nominal size, pressure designation, facing, bolt-hole pattern and face-to-face limits. A flanged appearance does not prove that the offered valve will fit the existing line.

Closing response and surges

For frequent pump starts/stops, pulsating flow or fast flow reversal, request the closing behavior and a surge assessment where appropriate. A standard check-valve name alone does not guarantee non-slam performance; a quick-closing design may need comparison.

Drawings and inspection

Request the configuration-specific general arrangement and section, material schedule, allowable mounting orientation, applicable GB or other standard editions, pressure/seat test criteria and any contract-required inspection records.

Selection boundary

When to compare another check-valve design

The deciding factor is the service, not just the model name. These three cases change the specification or the alternatives you should request.

Frequent pump trip or surge

Where rapid reverse flow may develop, ask for closing response and compare a suitable quick-closing check-valve design. No valve type can be promised to eliminate water hammer without evaluating the piping system.

Vertical or variable-flow service

Do not approve a vertical installation or very low normal flow from the exterior picture. Verify the specific manufacturer’s mounting instructions and stable-opening requirements; compare lift or other suitable check-valve designs if necessary.

Replacement into an existing line

Before replacing an installed unit, match flange drilling and facing, face-to-face dimension, valve orientation, maintainable clearance and actual P/T/material requirements to an approved drawing.

Technical inquiry

Request an H44W drawing and quotation

Reference GB Standard H44W Check Valve (catalog p. 82), attach your piping duty and, for replacements, the existing valve drawing. Ask VALMORA to confirm the offered model and issue documents matching the quotation.

Fields marked * are required.