PDF-documented product
Slab Gate Valve
The supplied English catalog shows two separate entries labeled “Slab Gate Valve” on PDF page 111. The image shown here matches the lower entry in the fifth column and is the catalog image assigned to this product page. The catalog does not establish whether the two same-name entries refer to the same model, related variants or separate products. This listing is not a model-specific datasheet; confirm the exact offered model, bore, pressure–temperature rating, materials, seat arrangement, end dimensions, actuation and applicable standard from its approved datasheet and drawing.
- Catalog family: Gate Valve
- Catalog construction label: Slab gate
Catalog evidence
Catalog-documented product data
The catalog page 111 contains two separate entries labeled “Slab Gate Valve,” each with a different photograph. The image shown on this page matches the lower entry in the fifth column. The catalog does not establish whether the two same-name entries refer to the same model, related variants or separate products. Only the source fields below are treated as confirmed product information.
↔ Scroll horizontally to read the full table
Source catalog
Open the Lianggong product catalog (PDF page 111)
| Catalog field | Source entry | What it establishes |
|---|---|---|
| Product name | Slab Gate Valve | The catalog listing name only; it is not a model number or performance rating. |
| Valve family | Gate Valve | Family classification only. |
| Catalog series | Oil Field Valve Series | The source catalog grouping; not proof of a specific process medium, service qualification or governing standard. |
| Same-name catalog entries | Two separate “Slab Gate Valve” labels on PDF page 111 | The image shown on this page matches the lower entry in the fifth column. The catalog does not establish whether the two entries are the same model, related variants or separate products. |
| Catalog product photo | Lower fifth-column Slab Gate Valve entry | Visual identity reference only; not a dimensional drawing or material/rating record. |
The supplied catalog entry does not state a manufacturer model number, nominal size, bore, pressure–temperature envelope, material grades, seat/seal design, end-connection standard, actuation specification or test basis. Obtain the exact offered configuration’s datasheet and approved drawing before technical approval, installation planning or purchase.
Engineering selection
Specify the configuration, not just the catalog name
The word “slab” does not establish whether the valve is through-conduit, full-bore, piggable or designed for a particular seat/isolation function. These are model-specific design features. Define the required valve duty and installation conditions first, then ask the supplier to show how the exact offered valve meets them.
Duty, flow passage and pigging
State whether the valve is for on/off isolation or another duty. If throttling or frequent cycling is required, request explicit confirmation that the offered design is suitable for that duty. If the line must be pigged or scraped, specify the pig envelope and minimum clear-bore diameter. Confirm whether the offered design is through-conduit and whether its bore is full or reduced; request a sectional drawing. Do not infer piggability from the name “Slab Gate Valve.”
Isolation and seat arrangement
State the required isolation direction, leakage criterion and whether the project calls for double block and bleed (DBB) or double isolation and bleed (DIB). They describe different seat-isolation arrangements and must not be used interchangeably. For DBB, require two seating surfaces to isolate the two ends and a defined means to bleed the body cavity; for DIB, require the supplier to state how each seat seals against its specified pressure source and how the cavity is vented or bled. Request the seat schematic and applicable test procedure.
Pressure, temperature and duty
Provide design and operating pressure/temperature, differential pressure at opening and closing, transient or vacuum cases, cycle frequency and required shutoff. Request the model-specific pressure–temperature rating and test basis; a class designation alone is not the complete operating envelope.
Fluid, materials and end connections
Describe the fluid phase, composition and concentration, solids, corrosive or erosive constituents, sour-service needs and cleaning requirements. Identify the plant, equipment and piping function, flow direction and installation orientation. Confirm body, gate, seat, seal and packing materials, plus end type, facing, bore and face-to-face dimensions. Check piping loads, available space, access, ambient conditions, maintenance method and mating interfaces against the approved drawing.
Operator, standard and records
The catalog product photo shows a handwheel, but the supplied entry does not specify the final operator. State manual or actuated operation; for an actuator, provide required torque, utilities, control/fail action and ambient conditions.
If the project references API 6D or API 6A, confirm that the equipment falls within the relevant scope and state the edition: API Specification 6D covers pipeline and piping valves, while API Specification 6A covers wellhead and tree equipment. The catalog label assigns neither. Request the model-specific datasheet, GA/sectional drawing, material records and pressure/seat-test requirements.
Series context
A separate Electric Slab Gate Valve image from the same catalog page
The separate image below shows the Electric Slab Gate Valve entry on the same catalog page. It is included for series context only; it is not the product image shown above. The product image for this listing appears in the hero.
Related catalog entries
Compare separate slab-gate catalog records
The catalog lists other named variants. Each linked page represents a separate catalog identity; its operator or service descriptor must not be treated as an option or specification for this valve.
Electric Slab Gate Valve
Separate catalog entry. Its title identifies an electric variant; actuator model, power supply, control signal, torque and fail action require confirmation from that entry’s own technical documents.
Bevel Gear Slab Gate Valve
Separate catalog entry. The bevel-gear designation identifies a different operator arrangement; gear ratio, input torque and stem configuration require its own datasheet.
Gas Specific Non-Rising Stem Slab Gate Valve
Separate catalog entry. The catalog title includes “Gas Specific” and “Non-Rising Stem”; gas-service qualification, pressure/temperature limits, sealing details and the applicable standard still require its own technical evidence.
Technical RFQ
Request a configuration review for Slab Gate Valve
Reference the Slab Gate Valve listing and send the operating case, required flow passage, isolation function and piping interfaces. Request the exact offered configuration’s datasheet, approved drawing and applicable inspection/test documents before technical approval.
- Valve duty, medium composition/phase, solids and operating cycles
- Required bore and pigging/through-conduit needs; minimum clear-bore dimension
- Design and operating pressure/temperature, differential pressure and transient cases
- Seat arrangement, isolation direction, leakage criterion and any DBB/DIB requirement
- End type/facing, face-to-face dimensions, installation orientation, materials, operator/actuation, quantity, project standard/edition, inspection/test plan, required witness or hold points, and project documentation list