The source English catalog identifies this entry as Electric Slab Gate Valve on PDF viewer page 111 (printed page 211). It confirms a gate-valve family, a slab-gate construction label and electric actuation. It does not state the stem arrangement, seat design, pressure-temperature rating or orderable size.
- Valve family: Gate Valve
- Catalog construction label: Slab gate
- Actuation: Electric
Product identity
What this catalog record identifies
This page identifies one entry in the source product catalog, not a complete project specification. The catalog label does not establish a model number, pressure-temperature rating, material grade, end connection or project approval.
Product family
Gate Valve. Use the parent category to compare gate-valve constructions and operating arrangements.
Catalog series
Oil Field Valve Series. This is the source catalog section heading, not proof of a particular oilfield service rating or approval.
Evidence source
English product catalog, PDF viewer page 111 (printed page 211). The linked catalog and matched product image are identity references only.
Catalog evidence
Catalog-documented product data
The source page shows several gate-valve entries together. Only the entry labeled Electric Slab Gate Valve is attributed to this page; neighboring product names do not establish this valve’s stem arrangement, pressure rating, materials or seat design.
| Field | Catalog-documented value | Evidence status |
|---|---|---|
| Valve type | Gate Valve | VERIFIED — PDF catalog label |
| Catalog construction label | Slab gate | VERIFIED — PDF catalog label |
| Actuation | Electric | VERIFIED — PDF catalog label |
| Catalog source series | Oil Field Valve Series | VERIFIED — PDF catalog section |
| Catalog source page | PDF viewer page 111 (printed page 211) | VERIFIED — recovered catalog mapping |
Important: The catalog does not state DN/NPS, pressure class, pressure-temperature limits, material grades, end connections or a seat-leakage criterion for this entry. Confirm these against the datasheet and approved drawing for the offered configuration.
Evidence boundary
Known facts and open configuration fields
The catalog confirms the product name, family label, slab-gate descriptor and electric actuation. It does not identify the stem movement, exact gate geometry, seat arrangement, bore design or actuator sizing basis.
Confirmed by the catalog
- Valve family: Gate Valve — identifies the product family, not its pressure rating or service suitability.
- Construction descriptor: Slab gate — does not specify the exact gate geometry, bore, seat arrangement or stem travel.
- Actuation: Electric — does not identify actuator model, output thrust/torque, power supply or operating duty.
Confirm before quotation
- Stem arrangement and travel: rising or non-rising stem, total travel, position indication and open/closed overall height
- Gate and seat details: gate profile, seat arrangement/material, flow direction, bidirectional shutoff and any DBB/DIB or cavity-relief requirement
- Pressure and temperature: design/operating pressure, maximum differential pressure during opening and closing, temperature range, transients and any credible pressure-locking/thermal-binding case
- Size and ends: DN/NPS, end connection, flange facing or weld preparation, bore, face-to-face dimensions and mating-pipe details
- Materials: body, gate, stem, seats, packing and wetted trim, matched to the actual fluid and corrosion/erosion conditions
- Electric operator: required thrust/torque, actuator/gearbox interface, supply voltage/phase/frequency, controls, enclosure and hazardous-area requirements
- Operating duty: opening/closing time, cycle frequency, starts per hour, intermediate-position duty and required fail action
- Acceptance: leakage criterion, pressure/seat testing, inspection, marking, certificates, drawings and documentation scope
- Body/trim/seat details and material grades
- Testing, dimensions, certificates, price and lead time
Engineering review
How to specify the Electric Slab Gate Valve
For this electric slab-gate catalog entry, the key decision is whether the offered valve, stem and seat construction match the service and whether the electric operator can complete the required travel under the specified load. The catalog name alone cannot settle those points.
Duty and shutoff
State whether the valve is for on/off isolation, emergency isolation, bypass or another defined function. Give the expected operations per hour or day, required opening/closing time and any intermediate-position duty. Gate valves are generally used for isolation; do not specify continuous throttling unless the supplier confirms that this exact design and actuator are rated for it.
Pressure and operating load
Provide DN/NPS, design and operating pressure, maximum differential pressure during opening and closing, minimum/normal/maximum fluid temperature and credible transients. Where relevant, identify trapped-cavity pressure, pressure-locking or thermal-binding scenarios. Required stem thrust depends on the valve design and operating load; nominal size or a catalog pressure description is not enough to select the actuator.
Materials, seats and connections
Match the body, gate, stem, seats, packing and wetted trim to the fluid, temperature, solids and corrosion/erosion conditions. Confirm the seat arrangement, permitted flow direction, required leakage performance and whether bidirectional isolation or cavity-pressure relief is specified. Also confirm end type, flange facing or weld preparation and the mating interface.
Stem, actuator and clearances
Confirm rising or non-rising stem, stem travel and the overall height in fully open and closed positions. Allow clearance for stem movement, actuator access and removal. Specify the actuator/gearbox interface, required thrust or torque, power supply, control signals, enclosure or hazardous-area requirements, opening/closing time and operating duty.
Inspection and documents
Identify the applicable design and connection standards and editions, pressure/seat test basis, material traceability, inspection or witness points, marking and required records. Request the offered datasheet and approved outline/section drawing showing the stem travel, seat arrangement and actuator mounting.
Application boundary
Match the catalog identity to the real service
The Oil Field Valve wording identifies the source catalog series only. Actual service suitability, pressure limits, material compatibility, stem arrangement and seat behavior must be established from the offered configuration and project conditions.
Service medium
Provide fluid composition and phase, temperature, solids, corrosive or erosive constituents, contamination and cleaning/flush conditions. These inputs affect material and seat selection; the catalog label does not assign a service medium.
Industry and system
Identify the line function and isolation scenario, including normal and upset flow direction, bypass/vent/drain needs and any bore-continuity or pig-passage requirement. A slab-gate label alone does not establish a full-bore or piggable design.
Installation boundary
Confirm the permitted installation orientation, flow direction, stem direction, overhead clearance, actuator orientation, removal envelope, piping loads, ambient or hazardous-area conditions and maintenance access. Use the approved outline drawing before fixing platforms, supports or access routes.
Visual evidence
Catalog image for product identification
This image is matched to the Electric Slab Gate Valve catalog entry. It is an appearance reference, not a sectional or dimensional drawing; it does not confirm the internal gate/seat arrangement, rising or non-rising stem, dimensions, pressure rating, materials or actuator specification.
Related product routes
Related slab-gate catalog entries
These links lead to separate catalog records, not interchangeable configurations. Review each product’s own drawing and technical data; do not transfer its stem, operator, pressure or sealing details to this Electric Slab Gate Valve.
Bevel Gear Slab Gate Valve
Separate entry with bevel-gear operation named in the catalog. Confirm its own stem and operating details before comparing it with this electric-actuated entry.
Gas Specific Non-Rising Stem Slab Gate Valve
Separate entry explicitly naming a non-rising stem. That name does not establish the stem arrangement of the Electric Slab Gate Valve.
Slab Gate Valve
A separate general slab-gate catalog entry. Confirm its own gate, seat, stem and operator details before comparison.
Buyer questions
Electric Slab Gate Valve FAQ
The answers below distinguish the source catalog label from the construction and operating data required for a project-specific offer.
What does the PDF catalog confirm for this product?
The source catalog names this product Electric Slab Gate Valve in the Oil Field Valve Series. It identifies Gate Valve as the family, slab gate as the construction label and electric as the actuation type. It does not state the stem arrangement, seat design, pressure rating, size, materials or end connection.
Does the slab-gate label identify the stem arrangement?
No. Slab gate is the catalog’s gate/construction descriptor; rising or non-rising stem is a separate arrangement. The catalog separately names a Gas Specific Non-Rising Stem Slab Gate Valve, but that is another entry and does not identify this product’s stem. Request the offered assembly drawing, stem travel and fully open height.
Can the catalog image be used as a final dimensional reference?
No. It is an appearance reference matched to the catalog entry, not a dimensional or sectional drawing. Use the approved outline and section drawings to verify face-to-face dimensions, overall height, stem travel, actuator envelope, access and maintenance clearance.
What should be included in the RFQ?
Include the intended duty, medium, size, design pressure and temperature, maximum differential pressure, connection, materials, stem and seat requirements, electric supply and controls, operating frequency and travel time, quantity, and required tests and documents. Mark unknown values for supplier confirmation rather than assuming them.
Technical inquiry
Request a configuration review for Electric Slab Gate Valve
Reference this catalog identity and provide the known operating and installation data. The quotation should identify the offered stem, gate and seat arrangement, actuator sizing basis, pressure-temperature limits and inspection/document scope. Mark unknown values for supplier confirmation.
- Valve duty, fluid, flow direction and required shutoff/leakage performance
- DN/NPS, end connection, design pressure/temperature and maximum differential pressure
- Stem arrangement, open/closed envelope, access and maintenance clearance
- Seat arrangement, materials and any DBB/DIB or cavity-pressure-relief requirement
- Actuator output, power/control supply, travel time, operating frequency, quantity and document/test requirements