Skip to content

PDF-documented product

Electric Slab Gate Valve

Electric slab gate valve with electric actuator, catalog product image

The source English catalog identifies this entry as Electric Slab Gate Valve on PDF viewer page 111 (printed page 211). It confirms a gate-valve family, a slab-gate construction label and electric actuation. It does not state the stem arrangement, seat design, pressure-temperature rating or orderable size.

Product identity

What this catalog record identifies

This page identifies one entry in the source product catalog, not a complete project specification. The catalog label does not establish a model number, pressure-temperature rating, material grade, end connection or project approval.

Product family

Gate Valve. Use the parent category to compare gate-valve constructions and operating arrangements.

Catalog series

Oil Field Valve Series. This is the source catalog section heading, not proof of a particular oilfield service rating or approval.

Evidence source

English product catalog, PDF viewer page 111 (printed page 211). The linked catalog and matched product image are identity references only.

Catalog evidence

Catalog-documented product data

The source page shows several gate-valve entries together. Only the entry labeled Electric Slab Gate Valve is attributed to this page; neighboring product names do not establish this valve’s stem arrangement, pressure rating, materials or seat design.

FieldCatalog-documented valueEvidence status
Valve typeGate ValveVERIFIED — PDF catalog label
Catalog construction labelSlab gateVERIFIED — PDF catalog label
ActuationElectricVERIFIED — PDF catalog label
Catalog source seriesOil Field Valve SeriesVERIFIED — PDF catalog section
Catalog source pagePDF viewer page 111 (printed page 211)VERIFIED — recovered catalog mapping

Important: The catalog does not state DN/NPS, pressure class, pressure-temperature limits, material grades, end connections or a seat-leakage criterion for this entry. Confirm these against the datasheet and approved drawing for the offered configuration.

Evidence boundary

Known facts and open configuration fields

The catalog confirms the product name, family label, slab-gate descriptor and electric actuation. It does not identify the stem movement, exact gate geometry, seat arrangement, bore design or actuator sizing basis.

Confirmed by the catalog

Confirm before quotation

Engineering review

How to specify the Electric Slab Gate Valve

For this electric slab-gate catalog entry, the key decision is whether the offered valve, stem and seat construction match the service and whether the electric operator can complete the required travel under the specified load. The catalog name alone cannot settle those points.

Duty and shutoff

State whether the valve is for on/off isolation, emergency isolation, bypass or another defined function. Give the expected operations per hour or day, required opening/closing time and any intermediate-position duty. Gate valves are generally used for isolation; do not specify continuous throttling unless the supplier confirms that this exact design and actuator are rated for it.

Pressure and operating load

Provide DN/NPS, design and operating pressure, maximum differential pressure during opening and closing, minimum/normal/maximum fluid temperature and credible transients. Where relevant, identify trapped-cavity pressure, pressure-locking or thermal-binding scenarios. Required stem thrust depends on the valve design and operating load; nominal size or a catalog pressure description is not enough to select the actuator.

Materials, seats and connections

Match the body, gate, stem, seats, packing and wetted trim to the fluid, temperature, solids and corrosion/erosion conditions. Confirm the seat arrangement, permitted flow direction, required leakage performance and whether bidirectional isolation or cavity-pressure relief is specified. Also confirm end type, flange facing or weld preparation and the mating interface.

Stem, actuator and clearances

Confirm rising or non-rising stem, stem travel and the overall height in fully open and closed positions. Allow clearance for stem movement, actuator access and removal. Specify the actuator/gearbox interface, required thrust or torque, power supply, control signals, enclosure or hazardous-area requirements, opening/closing time and operating duty.

Inspection and documents

Identify the applicable design and connection standards and editions, pressure/seat test basis, material traceability, inspection or witness points, marking and required records. Request the offered datasheet and approved outline/section drawing showing the stem travel, seat arrangement and actuator mounting.

Application boundary

Match the catalog identity to the real service

The Oil Field Valve wording identifies the source catalog series only. Actual service suitability, pressure limits, material compatibility, stem arrangement and seat behavior must be established from the offered configuration and project conditions.

Service medium

Provide fluid composition and phase, temperature, solids, corrosive or erosive constituents, contamination and cleaning/flush conditions. These inputs affect material and seat selection; the catalog label does not assign a service medium.

Industry and system

Identify the line function and isolation scenario, including normal and upset flow direction, bypass/vent/drain needs and any bore-continuity or pig-passage requirement. A slab-gate label alone does not establish a full-bore or piggable design.

Installation boundary

Confirm the permitted installation orientation, flow direction, stem direction, overhead clearance, actuator orientation, removal envelope, piping loads, ambient or hazardous-area conditions and maintenance access. Use the approved outline drawing before fixing platforms, supports or access routes.

Buyer questions

Electric Slab Gate Valve FAQ

The answers below distinguish the source catalog label from the construction and operating data required for a project-specific offer.

What does the PDF catalog confirm for this product?

The source catalog names this product Electric Slab Gate Valve in the Oil Field Valve Series. It identifies Gate Valve as the family, slab gate as the construction label and electric as the actuation type. It does not state the stem arrangement, seat design, pressure rating, size, materials or end connection.

Does the slab-gate label identify the stem arrangement?

No. Slab gate is the catalog’s gate/construction descriptor; rising or non-rising stem is a separate arrangement. The catalog separately names a Gas Specific Non-Rising Stem Slab Gate Valve, but that is another entry and does not identify this product’s stem. Request the offered assembly drawing, stem travel and fully open height.

Can the catalog image be used as a final dimensional reference?

No. It is an appearance reference matched to the catalog entry, not a dimensional or sectional drawing. Use the approved outline and section drawings to verify face-to-face dimensions, overall height, stem travel, actuator envelope, access and maintenance clearance.

What should be included in the RFQ?

Include the intended duty, medium, size, design pressure and temperature, maximum differential pressure, connection, materials, stem and seat requirements, electric supply and controls, operating frequency and travel time, quantity, and required tests and documents. Mark unknown values for supplier confirmation rather than assuming them.

Technical inquiry

Request a configuration review for Electric Slab Gate Valve

Reference this catalog identity and provide the known operating and installation data. The quotation should identify the offered stem, gate and seat arrangement, actuator sizing basis, pressure-temperature limits and inspection/document scope. Mark unknown values for supplier confirmation.

Fields marked * are required.