Skip to content

Catalog-listed product

Pneumatic Slab Gate Valve

Pneumatic slab gate valve assembly with a cylindrical actuator above the valve body, shown in the supplier catalog.

The supplier catalog lists this product as a Pneumatic Slab Gate Valve in its Oil Field Valve series. The confirmed labels are Gate Valve, slab gate and pneumatic actuation; the catalog does not specify the stem arrangement, detailed gate or seat design, operating rating, materials, connections or actuator package. Use the proposed product drawing and datasheet to confirm the configuration for your duty.

Product identity

What this catalog record identifies

This is one product-level catalog entry within the wider Gate Valve range. Use it to identify the requested configuration; compare other operator or stem arrangements through their own catalog records.

Product family

Gate Valve — the parent category for the wider valve family and product routes.

Catalog series

Oil Field Valve — the source catalog grouping, not proof of suitability for a particular oilfield duty or project specification. Compare the other catalog-listed slab-gate arrangements on the Oilfield Valves series page.

Evidence source

Lianggong Valve Product Catalog, Oil Field Valve series, PDF viewer page 111 (printed pages 211–212).

Catalog evidence

What the product catalog confirms

Only attributes explicitly shown in the source catalog are listed here. No numeric rating, material grade or connection standard is inferred from the product name or image.

FieldCatalog-documented valueEvidence status
Valve typeGate ValveVERIFIED — PDF catalog label
Design / constructionSlab gateVERIFIED — PDF catalog label
ActuationPneumaticVERIFIED — PDF catalog label
Catalog source seriesOil Field ValveVERIFIED — PDF section heading
Catalog referencePDF viewer page 111 (printed pages 211–212)VERIFIED — source PDF spread

No size range, pressure class, material grade, connection standard, sealing design or actuator rating is stated here. Confirm the exact offered values against the model-specific datasheet and approved drawings before order approval.

Construction and actuation

What the catalog labels do not tell you

“Slab gate” identifies the catalog construction family, not the complete internal design. “Pneumatic” identifies the operating method, not a sized actuator package. Neither label is enough to confirm installation fit or shutoff performance.

Gate and stem arrangement

Pneumatic actuator package

Engineering review

Specify the valve and pneumatic package together

For a gate valve, actuator selection depends on the operating load at the specified differential pressure and the required stroke time—not just nominal size or the word “pneumatic.” Provide the duty and ask the supplier to document the sizing basis for the offered valve/actuator combination.

Valve duty

Treat this entry as an on/off isolation candidate unless the proposed design documentation confirms another duty. State whether the valve is for routine isolation, emergency isolation, bypass or another defined function, and whether it will be asked to modulate flow. If continuous throttling is required, compare a control or globe valve instead of assuming a slab gate is suitable. Include cycle frequency and the maximum differential pressure during opening and closing.

Operating envelope

Provide nominal size, design and operating pressure, minimum/normal/maximum temperature, maximum differential pressure and any relevant transient or vacuum condition. No pressure class is stated in this catalog entry; request the pressure–temperature envelope for the proposed material and design.

Materials and connection

Specify body, gate, stem, trim, seat and seal material requirements against the actual fluid and temperature, including corrosion or erosion concerns. Confirm the end type, dimensional standard, facing or weld preparation, and mating pipe/equipment interface; none is defined by the catalog labels.

Pneumatic package data

Provide the minimum available instrument-air or other approved pneumatic supply pressure and quality, actuator action (for example, double-acting or spring-return where applicable), required response on loss of air, opening/closing time, cycle duty and any solenoid, limit switch, position feedback, positioner or manual override required. Ask the supplier to document actuator output against the valve’s required thrust at the stated differential pressure.

Inspection and documents

Request a model-specific datasheet, sectional and general-arrangement drawings, actuator sizing information, and the material, pressure and seat-leakage test, inspection, marking and third-party witness records required by the project. Ask which records are available for the quoted configuration; the catalog does not establish that they have been issued.

Application fit

Match the catalog entry to the site conditions

The Oil Field Valve series heading is a catalog grouping, not an application approval. Confirm the fluid, equipment function and installation envelope before treating the entry as a fit for an oilfield or other process system.

Service medium

Identify the fluid phase and composition, concentration, solids or contamination, corrosive/erosive constituents and cleaning requirements. These inputs affect wetted materials and seat compatibility; no service medium is assigned by the catalog entry.

Industry and system

Name the equipment and line function, the isolation point, normal operating sequence and any pressure-equalization or bypass arrangement. An industry label alone does not define the valve’s duty, design basis or project qualification.

Installation boundary

Confirm flow direction and mounting orientation where relevant, piping loads, end-to-end dimensions, total actuator height and width, available headroom and side clearance, pneumatic tubing/control access, maintenance access and actuator-removal space. Check the complete assembly envelope against the general-arrangement drawing before finalizing the layout.

Buyer questions

Pneumatic Slab Gate Valve FAQ

The catalog establishes the product identity and three named attributes; it does not replace the project datasheet, drawings or actuator sizing review.

Which product details are confirmed by the catalog?

The catalog identifies a Gate Valve, a slab-gate construction label and pneumatic actuation under the Oil Field Valve series. It does not state numeric size, pressure/temperature rating, material grade, end connection or actuator model.

Does this product use a rising or non-rising stem?

The Pneumatic Slab Gate Valve catalog entry does not specify the stem arrangement. The separate Gas Specific Non-Rising Stem Slab Gate Valve is a different catalog record. Confirm this product’s stem travel and topworks from its own sectional and general-arrangement drawings.

How should the pneumatic actuator be sized?

Provide the maximum differential pressure, required opening and closing times, cycle duty, minimum available air pressure and required response on loss of air. Ask the supplier to document actuator output and margin against the valve’s required operating thrust for the offered assembly.

What should be checked before installation or purchase?

Confirm the valve end connections, stem and actuator envelope, mounting orientation, gate/seat sealing direction, material and pressure-temperature limits, and project test/inspection requirements. Use the approved datasheet and drawings—not the catalog image—for layout and order acceptance.

Technical inquiry

Request a configuration review for Pneumatic Slab Gate Valve

Reference this catalog identity and provide the known operating and installation data. If the stem arrangement, sealing direction, rating, material or actuator requirement is not yet defined, mark it as open. Request the proposed datasheet, general-arrangement/sectional drawings and actuator sizing basis before approving the configuration.

Fields marked * are required.