Catalog-identified pneumatic control valve
Pneumatic Diaphragm Control Valve
The supplier catalog identifies a Pneumatic Diaphragm Control Valve and illustrates the red pneumatic-actuator assembly shown here. It does not specify an orderable model, flow coefficient, pressure-temperature rating, trim, or fail position. Use the operating conditions below to request a configuration-specific datasheet and quotation.
- Catalog identity: Pneumatic Diaphragm Control Valve
- Sizing, actuator action and accessory package: to be specified
Documented facts
What is confirmed for this catalog product?
The source shows two separate entries labeled Pneumatic Diaphragm Control Valve; the red-actuator illustration corresponds to this page’s retained target image. A nearby blue handwheel-equipped illustration is labeled Pneumatic Single-Seat Control Valve and is not proof of this item’s model or rating. The PDF provides names and images, not a configuration-specific performance table.
| Field | Documented information | Evidence boundary |
|---|---|---|
| Catalog product name | Pneumatic Diaphragm Control Valve | CATALOG LABEL |
| Source family | Control Valve Series | CATALOG HEADING |
| Pneumatic arrangement | Diaphragm-type actuator illustrated; final actuation package not specified | CATALOG IMAGE / IDENTIFICATION ONLY |
| Source location | Supplier catalog, physical PDF page 100 (printed spread 189–190) | CATALOG SOURCE |
| Model and technical limits | No confirmed orderable model, DN/NPS range, PN/Class range, Cv/Kv, temperature limit, trim or fail position | NOT DOCUMENTED FOR THIS OFFER |
For quotation, ask for the offered model’s datasheet. Image markings and ratings on other valves in the same catalog spread cannot be transferred to this record.
Configuration review
Size the control duty before selecting the actuator
Start with the controlling process case, not nominal pipe size or the actuator shown in the photo. The selected valve must handle the required flow and the differential pressure at minimum, normal and maximum conditions; the pneumatic actuator must then supply adequate stroke force at the available instrument-air pressure, including the specified shutoff case.
Process flow and controllability
Buyer input: fluid composition and state, density or specific gravity, viscosity where relevant, vapor pressure for liquids, and minimum/normal/maximum flow with upstream and downstream pressure at each case. Review outcome: calculate required Cv/Kv and check the offered trim characteristic and minimum controllable flow. Pipe size by itself cannot establish the Cv.
Pressure drop and service limits
Give design/operating pressures and temperatures, maximum differential pressure during shutoff, and any vacuum or transient conditions. Large liquid pressure drops call for a cavitation/flashing review; gas or steam duty may need choked-flow and noise evaluation. These are sizing checks, not catalog-proven capabilities of this valve.
Body, trim and piping interfaces
Specify medium compatibility, corrosion/erosion exposure, requested body and trim materials, seat/packing requirements, pipe size and end-connection standard. Also provide expected piping loads, ambient operating conditions and space/access for inspection and maintenance. Obtain an offered drawing for flange facing, face-to-face dimensions, flow direction and installation clearance; none is defined for this item by the source spread.
Instrument air and loss-of-air action
State minimum/normal/maximum instrument-air supply pressure, air quality, input signal, and whether the process must fail closed, fail open or hold position. A spring-return diaphragm actuator can be arranged for different failure actions, but this catalog image does not establish which is supplied. Loss of air and loss of control signal must be checked separately with the offered positioner, solenoid and accessories.
Data and acceptance documents
Request the exact offered-model datasheet with the selected valve/trim’s rated Cv or Kvs and flow characteristic, shutoff differential-pressure rating, actuator sizing/bench range, air demand and approved accessory list. Separately request a sizing record comparing calculated required Cv/Kv at minimum, normal and maximum process cases with the selected trim’s capacity and controllable range. Add a general-arrangement drawing, leakage criterion, applicable test records and material documents when required by the project. These are requested deliverables, not included or certified features.
Alternative control-valve routes
Compare the actuation route—not inherited ratings
The Control Valves category organizes the available product paths; the Globe Control Valves series explains series-level selection. The three catalog records below remain separate items. Their sizes, temperature claims and actuation packages do not establish specifications for this pneumatic diaphragm listing.
Pneumatic Forged Steel Control Valve
A distinct pneumatic forged-steel catalog identity. Check its own body construction and service limits before comparing offers.
Electric Control Valve
An electric-actuation route; compare power/control infrastructure and required fail response rather than assuming pneumatic accessories.
Electric High Temperature Control Valve
A separate electrically actuated high-temperature catalog identity. The descriptive name does not establish a temperature range for this product.
Key procurement distinctions
Questions that change the specification
The supplier must confirm the final model and pneumatic package; these answers clarify what cannot be inferred from the catalog images.
Does “diaphragm” mean this is a diaphragm isolation valve?
No. In this catalog entry, it refers to the pneumatic diaphragm actuator illustrated above the control valve. It is not evidence that the process valve uses a flexible diaphragm as its shutoff element.
Can the blue handwheel valve photo be used for this item’s rating?
No. The PDF labels that different illustration Pneumatic Single-Seat Control Valve. Its cast markings, size and other visible features must not be carried over to this listing.
Is the pictured actuator fail closed or fail open?
The catalog does not say. The required response to loss of instrument air and loss of control signal must be defined by the buyer and verified against the offered actuator spring arrangement and accessories.
What is needed before selecting a size or issuing a purchase order?
Provide the fluid, minimum/normal/maximum flow and associated upstream/downstream pressures, temperature limits, required shutoff and fail action, available instrument air, piping interfaces and document requirements. Request the exact model, Cv/Kv sizing and approved drawing in return.
Request an offered configuration
Request a pneumatic diaphragm control valve quotation
Send the process cases and required fail behavior with this catalog reference. Ask VALMORA to return the exact offered model, sizing record, actuator/accessory specification, drawing and document scope before technical acceptance.
- Fluid, minimum/normal/maximum flow, and corresponding P1/P2
- Design and operating pressure/temperature; maximum shutoff differential
- Connection and requested wetted materials; seat leakage target
- Instrument-air range, input signal, required fail action and accessories