Skip to content

PDF-documented product

Titanium Ball Valve

Titanium Ball Valve product image from the source catalog, reference 104_08

The recovered source catalog lists Titanium Ball Valve under the Special Valve series on PDF page 104. This confirms the catalog identity—not a titanium grade, pressure-temperature rating, seat design, bore or actuator package. Send the actual process conditions for a configuration-specific review.

Product identity

What the source catalog identifies

This page covers one catalog entry. It does not assign a model, material grade, pressure class, temperature range, bore, end connection or operating method. Those details must come from the offered datasheet and approved order drawing.

Product family

Ball Valve. Use the parent Ball Valve category to compare valve functions and series; this page covers the titanium-labeled catalog entry only.

Catalog series

Special Valve. This is the source-catalog section label, not a design standard, pressure class or performance rating.

Evidence source

Recovered English product catalog, PDF page 104. The two mapped images are catalog entries 104_08 (AST-R1-0376) and 104_14 (AST-R1-0382).

Catalog evidence

Catalog-documented product data

Only fields stated in the source catalog are shown as product data. A descriptive label does not establish a numeric pressure rating, size range, temperature limit, design standard or certification.

FieldCatalog-documented valueEvidence status
Valve typeBall ValveVERIFIED — PDF catalog label
Material descriptorTitaniumVERIFIED — PDF catalog label
Catalog source seriesSpecial ValveVERIFIED — PDF catalog section
Catalog source pagePDF page 104VERIFIED — recovered PDF mapping

Important: Values not shown in this table are not implied. Confirm them against the offered datasheet, material records and approved order drawing before technical approval.

Evidence boundary

What is confirmed—and what remains open

The catalog establishes the product name, valve type, titanium material descriptor and source-series context. It does not establish the exact alloy grade, wetted-part schedule, pressure/temperature envelope, seat leakage performance or order-ready configuration.

Confirmed by the catalog

Confirm before quotation

Engineering review

How to specify the Titanium Ball Valve

Start with the fluid chemistry and duty; they determine whether the proposed titanium grade and seat materials are viable. Then check the bore and flow path against the required service, verify the shutoff differential-pressure and temperature cases, and size the operator from the resulting valve torque. Confirm the maintenance envelope before the configuration is finalized.

Duty and flow path

State whether the valve is for on/off isolation, emergency shutoff, bypass or modulating control. Provide the normal and peak flow cases, required bore, allowable pressure loss, solids/pigging or cleaning needs, and any required flow direction. Do not assume a standard on/off ball valve is suitable for sustained throttling; request the offered control characteristic and flow-capacity data if modulation is required.

Pressure differential and temperature

Provide NPS/DN, design and normal operating pressures, maximum differential pressure across the closed valve, minimum/maximum temperatures, and any start-up, shutdown, vacuum or upset cases. Line pressure alone does not define the seat shutoff duty or operating torque; check the offered body and seat combination against the full pressure-temperature envelope.

Titanium grade, trim and seats

The catalog says Titanium but does not identify a grade or component schedule. Specify the required body grade and confirm the ball, stem, trim, seats, seals, packing and gaskets for the same service. Confirm end type, facing and dimensional standard separately; do not assume the body material defines the complete wetted-part system.

Operating torque and actuation

For manual, gear or powered operation, request valve-specific breakaway, running and closing torque at the specified differential-pressure and temperature cases. Torque also depends on seat material, medium and cycle frequency. For an actuator, state the available supply, fail action, required stroke time and feedback; verify actuator output and maximum allowable stem torque against the valve data.

Inspection and documents

Identify the applicable design and test standards with edition, required material certificates and traceability, pressure-shell and seat-leakage tests, inspection or hold points, marking, and any third-party witness. Request the datasheet and order drawing that bind the final materials, dimensions, limits and operator into one configuration.

Application boundary

Check titanium against the real service

Titanium is not a universal corrosion-resistant answer. Performance depends on the exact grade, fluid chemistry, concentration, temperature, impurities and flow conditions; select the complete wetted-part system, not the body label alone.

Service medium

Provide the full fluid composition and concentration, pH, oxidizing or reducing conditions, chloride/fluoride content, water content, solids, velocity and cleaning chemicals. Some titanium grades perform well in many oxidizing and chloride services, while reducing acids and fluoride-containing media can be more aggressive; obtain a grade-specific corrosion review before approval.

Industry and system

An industry label does not define the valve duty. The same plant may need separate valves for block isolation, bypass and flow control, each with different seat, port and operator requirements. Select by the actual line function rather than the sector name.

Installation boundary

Provide installation orientation, flow direction if the seat design is directional, pipe supports and loads, operator orientation, handwheel/gearbox/actuator removal envelope, tool and lifting clearance, and access to stem packing, body joints or seat service. State whether routine service must be possible in-line or whether the valve can be removed for maintenance.

Buyer questions

Titanium Ball Valve FAQ

The answers below distinguish catalog identity from the engineering data needed to select and quote a valve.

What does the source catalog confirm?

It lists Titanium Ball Valve as a Ball Valve under the Special Valve series on PDF page 104 and maps two product images, references 104_08 and 104_14. It does not state a titanium grade, design, rating, seat, connection or actuation.

Is titanium suitable for any corrosive medium?

No. Suitability depends on the exact grade, fluid chemistry, concentration, temperature, impurities and flow conditions. Some reducing acids and fluoride-containing media can attack titanium. Confirm the complete fluid chemistry and each wetted component before selection.

How should pressure differential and torque be specified?

Provide maximum differential pressure at shutoff, minimum/maximum temperature, valve size and seat design. Request breakaway, running and closing torque for those cases; actuator sizing also needs supply, fail action, cycle frequency and stem torque limit.

What should be included in the RFQ?

Send the valve duty and normal/peak flow cases, required bore and allowable pressure loss; full fluid composition and concentration, contaminants, solids and cleaning chemicals; NPS/DN, design pressure, maximum shutoff differential pressure and minimum/maximum temperature; the required titanium grade, wetted trim, seat/seal materials, end connection and shutoff leakage criterion; and the operator, valve torque data, available utilities, fail action, maintenance access, quantity, drawings, tests and inspection/document requirements. Ask the supplier to confirm price and lead time against the final offered configuration.

Technical inquiry

Request a configuration review for Titanium Ball Valve

Reference this catalog identity and include the duty, medium chemistry, pressure differential, temperature range, flow path, seat and material requirements, operator and maintenance access. VALMORA can then confirm which configuration and documents can be offered; unspecified values remain subject to written confirmation.

Fields marked * are required.