Skip to content

PDF-documented product

Electric Titanium Ball Valve

Catalog image of the Electric Titanium Ball Valve with an electric actuator and flanged ends

The recovered English catalog identifies this item as Electric Titanium Ball Valve on PDF page 104. It records the valve type, titanium material descriptor and electric actuation; the exact grade, pressure limits, seat design, flow path and actuator specification still require the offered product documents.

Product identity

What this catalog record owns

This page represents one documented catalog identity. It does not replace the parent product category and it does not claim an unverified model, rating or project history.

Product family

Ball Valve. This is the parent commercial route for category-level selection.

Catalog series

Special Valve. This is the source-series context printed in the recovered product catalog.

Evidence source

Recovered source English product catalog, PDF page 104; mapped product image AST-R1-0374 (catalog token 104_06).

Catalog evidence

Catalog-documented product data

The catalog label confirms only the fields listed below. “Titanium” does not identify a material grade or every wetted part, and “Electric” does not define the actuator voltage, controls, duty or power-loss action.

FieldCatalog-documented valueEvidence status
Valve typeBall ValveVERIFIED — PDF catalog label
Material descriptorTitaniumVERIFIED — PDF catalog label
ActuationElectricVERIFIED — PDF catalog label
Catalog source seriesSpecial ValveVERIFIED — PDF catalog section
Catalog source pagePDF page 104VERIFIED — recovered PDF mapping

Important: values not shown in this table are intentionally unconfirmed. They must be resolved on the offered datasheet and approved order drawing.

Evidence boundary

Known facts and open configuration fields

The PDF proves the product label and mapped appearance. It does not by itself prove a complete bill of materials, operating envelope or order-ready model.

Confirmed by the catalog

Confirm before quotation

Engineering review

How to specify the Electric Titanium Ball Valve

Specify the valve and electric actuator as one package. The catalog confirms the product identity, but the service duty, seat arrangement, pressure differential and actuator torque determine whether the offered configuration is suitable.

Valve duty

State whether the duty is on/off isolation or modulating service, together with cycle frequency and required leakage performance. If continuous throttling is required, ask the supplier to confirm a suitable port/trim and provide sizing data; an electric actuator alone does not make an on/off ball valve suitable for control.

Operating envelope

Provide nominal size, design and operating pressure, upstream/downstream pressure at opening and closing, maximum differential pressure, minimum/maximum temperature, and any start-up, shutdown, vacuum or trapped-cavity cases. Confirm the allowable shutoff differential pressure for the offered seat arrangement; body pressure class alone does not establish it or the actuator torque requirement.

Materials and connection

Treat Titanium as a catalog material descriptor, not a complete grade specification. Confirm the exact body grade and all wetted materials, including ball, stem, seats and seals, against the fluid chemistry, concentration, contaminants and cleaning method. Also specify full/reduced bore or another port arrangement, end connection and dimensional standard.

Electric actuator data

Request the valve breakaway, running and seating torque at the maximum specified differential pressure and relevant temperature, medium and seat condition. Match actuator output at the actual supply conditions to the required torque with the supplier’s stated sizing margin, without exceeding the valve’s maximum allowable stem torque. Confirm voltage, control signal, on/off or modulating duty, cycle frequency, power-loss action, enclosure/IP, local controls, feedback and mounting interface.

Inspection and documents

List the drawing and datasheet, material certificates, pressure and seat-leakage tests, inspection, marking and any third-party witness or hold points required for the offered configuration. State the required document standard and acceptance criteria rather than assuming they are included.

Application boundary

Match the catalog identity to the real service

Product names are useful starting points, but final suitability depends on the complete operating case and the exact configuration offered for review.

Service medium

Provide the fluid composition, concentration, phase, solids or other contaminants, and cleaning requirements. The Titanium label alone cannot establish compatibility or service life for a specific process medium.

Industry and system

Identify the plant, equipment and piping function. If flow sizing or modulation is involved, include the required flow cases and pressure drop; an industry name by itself does not determine the valve design, port or material grade.

Installation boundary

Confirm mounting orientation, any required flow direction, piping loads and supports, ambient conditions and the intended maintenance method. Check clearance for actuator removal and electrical access, plus access to stem seals/packing and body fasteners where applicable. Use the offered outline drawing to verify the service and removal envelope.

Buyer questions

Electric Titanium Ball Valve FAQ

These answers preserve the line between documented catalog evidence and project-specific selection.

What does the PDF catalog confirm for this product?

The recovered catalog identifies the product as Electric Titanium Ball Valve and lists Ball Valve, Titanium, Electric and Special Valve. The matching image is catalog token 104_06 (AST-R1-0374); it does not provide a material grade, size, pressure rating or performance limit.

Which data still requires confirmation?

Confirm the valve construction, port/bore, end connection, titanium grade and other wetted materials, seat/seal materials, leakage requirement, service medium, temperature range and maximum shutoff differential pressure. The electric actuator’s torque data, supply, controls, duty, power-loss action and mounting also need confirmation, together with inspection documents, dimensions, price and lead time.

Can the catalog image be used as a final dimensional reference?

No. The image confirms catalog identity and appearance context only. Fabrication, installation and procurement must use the approved datasheet and order drawing.

What should be included in the RFQ?

Include the required isolation or modulating duty, medium and concentration, size and bore, end connection, design pressure and maximum differential pressure, temperature range, titanium grade and wetted materials, seat/seal and leakage requirement, actuator voltage/control/fail action and torque data, quantity, drawings, tests, certificates and inspection or witness scope.

Technical inquiry

Request a configuration review for Electric Titanium Ball Valve

Reference this catalog identity and send the operating data below. VALMORA can then confirm the offered configuration, documentation scope and commercial terms without turning unknown fields into assumptions.

Fields marked * are required.