The recovered catalog lists this item as Pneumatic Fixed Cast Steel Ball Valve. It confirms the Ball Valve family, cast-steel material descriptor and pneumatic actuation. It does not identify the actuator model, minimum air pressure, fail action, mounting interface, valve torque or included accessories; these must be confirmed for the quoted assembly.
- Valve type: Ball Valve
- Material descriptor: Cast steel
- Actuation: Pneumatic
Product identity
What this catalog record owns
This page preserves one catalog-listed product identity. The word “Fixed” is retained as part of the catalog name; the catalog does not define the ball-support arrangement, seat design, bore, pressure rating or actuator package.
Product family and catalog series
Ball Valve. The recovered catalog uses the same label for the parent product family and source series.
Evidence source
Recovered English product catalog, PDF page 91; mapped image from the Pneumatic Fixed Cast Steel Ball Valve entry.
Catalog evidence
Catalog-documented product data
Only fields stated by the PDF catalog are shown. The product name does not establish a pressure class, size range, material grade, internal ball-support design, seat arrangement or certification.
| Field | Catalog-documented value | Evidence status |
|---|---|---|
| Valve type | Ball Valve | VERIFIED — PDF catalog label |
| Material descriptor | Cast steel | VERIFIED — PDF catalog label |
| Actuation | Pneumatic | VERIFIED — PDF catalog label |
| Catalog source series | Ball Valve | VERIFIED — PDF catalog section |
| Catalog source page | PDF page 91 | VERIFIED — recovered PDF mapping |
Important: any value not shown must be confirmed in the offered datasheet and approved order drawing, including valve and actuator mounting dimensions.
Evidence boundary
Known facts and open configuration fields
The catalog confirms the product label and mapped appearance, not an order-ready valve and actuator specification. In particular, “Fixed” does not prove a trunnion-supported ball or a particular seat arrangement.
Confirmed by the catalog
- Valve type: Ball Valve — the catalog label confirms the product family, not the internal design.
- Material descriptor: Cast steel — this is not a complete body-grade, trim or wetted-parts schedule.
- Actuation: Pneumatic — the actuator model, supply range, fail response, torque output and package contents are not stated.
Confirm before quotation
- Internal construction: ball-support arrangement, seat design, port/bore and section drawing; do not infer these from “Fixed”.
- Pressure and size: NPS/DN, bore, pressure class or PN, design limits and operating limits.
- End connections: flange, weld or other end type, facing, dimensional standard and mating-pipe details.
- Service: medium, minimum/maximum temperature, differential pressure, solids, corrosion risks and cycle duty.
- Materials: exact body grade, trim, seats, seals, wetted parts and required material records.
- Actuator: make/model, double-acting or spring-return execution, rotation and required fail position.
- Instrument air: minimum/maximum pressure at the actuator inlet while stroking, air consumption, air quality and lubrication requirements.
- Mechanical interface: mounting flange, drive insert/coupling, bracket, stem dimensions, travel stops, orientation and clearance.
- Sizing: valve breakaway/running/re-seating torque, actuator output at minimum air pressure, maximum allowable stem torque and stroke time.
- Package scope: solenoid, filter regulator/gauge, limit switches, positioner, manual override, tubing/fittings, mounting kit and spare parts.
- Order documents: datasheets, GA/mounting drawings, pneumatic schematic, test/inspection records, certificates, marking, packing, price and lead time.
Engineering review
How to specify the Pneumatic Fixed Cast Steel Ball Valve
Treat the valve and actuator as one assembly. The valve must suit the process duty; the actuator must fit the valve mechanically and deliver the required torque with the air actually available at site. The catalog does not provide the data needed to approve either match.
Valve duty
State whether the requirement is on/off isolation, emergency action or modulating control, together with cycle frequency and required shutoff. The Ball Valve category separately lists pneumatic V-Type control and O-Type shut-off entries; this catalog name does not identify this item as either design.
Operating envelope
Provide NPS/DN, required bore, design and normal operating pressure, differential pressure across the valve, minimum/maximum process temperature, medium and any transient or vacuum cases. These conditions affect valve suitability and operating torque; nominal size or pressure class alone cannot size the actuator.
Materials and connection
Confirm the exact cast-steel body grade, trim, seats, seals and wetted-part materials, plus end-connection type, facing, dimensional standard and mating-pipe details. “Cast steel” is a catalog descriptor, not a material grade or a complete trim schedule.
Pneumatic package data
Request the actuator make/model, double-acting or spring-return execution, minimum and maximum supply pressure at the actuator inlet while stroking, air consumption per cycle, required stroke time and the actuator manufacturer’s air-quality and lubrication requirements. If the quoted package includes a solenoid valve, also state the coil supply type (AC or DC), rated voltage, frequency where applicable, power/current and electrical connection.
Inspection and documents
Request the valve and actuator datasheets, general-arrangement and mounting drawings, actuator torque-sizing sheet, pneumatic schematic, material records, pressure/leakage test basis, inspection or witness scope and project-required certificates. Keep every record tied to the same offered configuration and revision.
Pneumatic actuator checks before approval
| Check | What to verify | Why it matters |
|---|---|---|
| Mounting interface | Verify the valve top flange, actuator base, drive insert or key, stem dimensions, coupling, bracket and travel orientation as one assembly. If the project specifies ISO 5211, state the contract edition and verify the mating dimensions against it. | A matching flange pattern alone does not prove that the drive component, coupling or available clearance will fit. |
| Minimum instrument-air pressure | Specify the minimum and maximum pressure available at the actuator inlet while the actuator is moving, after losses through the air line, filter regulator, solenoid and manifold. Include available flow, air consumption per cycle and required stroke time. | Actuator torque and operating time depend on the pressure and flow that reach the actuator during the stroke, not simply the compressor discharge or nominal plant-header pressure. |
| Air quality and conditioning | Define particle, water/dew-point and oil limits from the actual actuator IOM and project instrument-air specification. Confirm operating temperature and whether dry air, lubricated air or no added lubrication is required. State an ISO 8573-1 purity class only when the project specifies one. | Air-treatment requirements are actuator-specific. The catalog does not state an air-quality class, dew point or lubrication requirement. |
| Action and failure response | Specify double-acting or spring-return operation and the required response to loss of instrument air. If the offered package includes an electrically operated solenoid valve or a powered/electro-pneumatic positioner or control device, also define the response to loss of electrical power or control signal. State the solenoid coil’s de-energized state only when a solenoid is included; specify loss-of-supply behavior for powered feedback devices where relevant. Confirm fail-open/closed direction, interlocks and position feedback for the offered configuration. | A double-acting actuator has no spring-defined fail direction. Electrical failure responses depend on the fitted control circuit and powered accessories; a passive limit switch alone does not define the actuator’s fail action. |
| Torque and stroke time | Obtain valve breakaway, running and seating/re-seating torque for the specified medium, differential pressure, operating-temperature range and cycle duty, identifying critical stroke positions and opening/closing directions. For each torque value, state whether an application/service margin or correction factor is already included. Whether included or applied separately, disclose the actual included or separate margin/factor value (or the calculation showing it), the directions and positions to which it applies, the service factors included, and the valve/actuator manufacturer document or project specification supporting it. If it is not included, state the proposed margin/factor and calculation method separately; do not count a margin twice. Provide the valve manufacturer’s MAST (Maximum Allowable Stem Torque), or define any equivalent manufacturer limit, with its value and units, the exact valve configuration to which it applies, the operating-temperature range and any temperature derating, plus the supporting manufacturer datasheet, drawing, calculation or test basis. Identify the allowable torque limits of the coupling, drive insert/key, actuator output interface and other torque-transmitting parts; the lowest applicable limit governs the assembly. Provide actuator output torque across the full stroke at both the minimum and maximum dynamic inlet air pressures that can reach the actuator under the offered supply/regulator arrangement, by opening/closing direction and critical stroke position. State the actuator manufacturer’s maximum permitted inlet pressure and identify any mismatch with the site maximum. For spring-return units, show air-stroke output at both pressure limits and spring-stroke output separately across the return stroke. At minimum pressure, verify that output meets the valve torque requirement with the documented margin applied only once. At maximum pressure, verify that output does not exceed the lowest applicable limit among MAST and all torque-transmitting components. | The minimum-pressure check establishes that the actuator can complete the required stroke under the lowest available supply condition. The maximum-pressure check protects the stem and drive train from overload. MAST is only one limit: a coupling, drive insert/key or other torque-transmitting part may have a lower allowable value, and that weakest limit governs. The catalog supplies none of these values, so the supplier must document them for the exact offered configuration and operating-temperature range. |
| Accessories and spare parts | Identify every accessory as included, optional or excluded in the quotation. If a solenoid valve is included, specify coil supply type (AC/DC), rated voltage, frequency where applicable, power/current, electrical connection and any project-required hazardous-area approval. If limit switches are included, state contact/output type (for example, dry contact/SPDT or powered proximity output), supply requirement where applicable, electrical rating and wiring/terminal interface. If a positioner is included, identify whether it is pneumatic or electro-pneumatic. For an electro-pneumatic unit, specify the electrical input/control signal, supply requirements, feedback/output signal where required, and connector/terminal interface; for a pneumatic unit, specify its pneumatic input signal and port/interface. Also itemize the filter regulator/gauge, speed controls, manual override, tubing/fittings, mounting kit and any lock-up or quick-exhaust devices. List repair kits and seals, spring cartridges only for spring-return configurations, and solenoid coils or switch parts by part number and quantity. | The catalog does not establish which accessories are supplied. Electrical ratings and signal interfaces must match the plant control system and the exact quoted devices; list each item as included, optional or excluded. |
Application boundary
Match the catalog identity to the real service
The catalog does not assign a process medium or industry. Suitability depends on the actual service, pressure/temperature envelope and control duty, not the catalog name alone.
Service medium
Provide fluid composition, phase, concentration, solids, contamination, corrosion or erosion risks and cleaning requirements. These conditions affect the body, trim and seat selection as well as the valve torque used for actuator sizing.
Industry and system
Identify the plant system, line function and whether the valve is intended for on/off isolation, emergency action or modulation. An industry label alone does not define the material, shutoff requirement or actuator response.
Installation boundary
Confirm pipeline and valve orientation, actuator orientation, mounting clearance, air-line routing, electrical-entry access, ambient conditions and maintenance space. Check that the actuator and accessories can be accessed or removed without clashing with adjacent equipment.
Visual evidence
Catalog-mapped product image
The image below matches the catalog’s Pneumatic Fixed Cast Steel Ball Valve entry on PDF page 91. It shows appearance only; it does not establish valve dimensions, internal construction, actuator model, mounting standard, pressure rating or supplied accessories.
Related product routes
Compare documented alternatives before RFQ
These linked pages are separate catalog identities. Review each product’s own evidence and offered configuration; no construction detail, pressure rating, material grade or actuation data transfers from one page to another.
Three-Piece Forged Steel High Pressure Ball Valve
Another PDF-documented Ball Valve catalog record. Review its own evidence and configuration boundary.
High Temperature and High Pressure Three-Piece Forged Steel Fixed Ball Valve
Another PDF-documented Ball Valve catalog record. Review its own evidence and configuration boundary.
Three-Piece Forged Steel Hard Sealed Fixed Ball Valve
Another PDF-documented Ball Valve catalog record. Review its own evidence and configuration boundary.
Buyer questions
Pneumatic Fixed Cast Steel Ball Valve FAQ
These answers separate the recovered catalog facts from the engineering and commercial data needed to approve the complete valve and actuator assembly.
What does the catalog confirm for this product?
The recovered PDF identifies the product as Pneumatic Fixed Cast Steel Ball Valve in the Ball Valve series and lists Ball Valve, Cast steel and Pneumatic as its catalog descriptors. It does not provide a complete valve or actuator datasheet.
What minimum air pressure does the actuator require?
No minimum or maximum air pressure is stated in the catalog. Obtain the actuator make and model, then size it using the minimum dynamic pressure available at the actuator inlet during the stroke. Also confirm air consumption, filtration, moisture/dew point, oil limits and lubrication requirements from the actuator IOM and project instrument-air specification.
How should the actuator torque be matched to the valve?
Request valve breakaway, running and seating/re-seating torque for the specified service, by opening/closing direction and critical stroke position. For every value, the supplier must state whether an application/service margin or correction factor is already included. Whether included or applied separately, require the actual margin/factor value (or the calculation showing it), the directions/positions and service factors to which it applies, and the supporting manufacturer document or project specification. If it is not included, require the proposed margin/factor and calculation method separately so it is not counted twice. Obtain the valve manufacturer’s MAST (Maximum Allowable Stem Torque), or a defined equivalent limit, with value and units, the applicable valve configuration, operating-temperature range and any temperature derating, plus the supporting manufacturer datasheet, drawing, calculation or test basis. Also obtain allowable torque limits for the coupling, drive insert/key, actuator output interface and other torque-transmitting parts; the lowest applicable limit governs. Require actuator output torque across the full stroke at both the minimum and maximum dynamic inlet air pressures that can reach the actuator under the offered supply/regulator arrangement, for each opening/closing direction and critical position. State the actuator manufacturer’s maximum permitted inlet pressure and identify any mismatch with the site maximum. For spring-return units, show air-stroke output at both pressure limits and spring-stroke output separately across the return stroke. At minimum pressure, verify that output meets the valve torque requirement with the documented margin applied only once; at maximum pressure, verify that output does not exceed the lowest applicable limit among MAST and all torque-transmitting components. Do not substitute a generic factor or apply a second margin where one is already included.
How should actuator failure responses be specified?
The catalog does not state a fail position. Define the required response to loss of instrument air for the selected double-acting or spring-return actuator. If the quoted package includes an electrically operated solenoid valve or a powered/electro-pneumatic positioner or control device, also specify the response to loss of electrical power or control signal. State the solenoid coil’s de-energized state only if a solenoid is included; specify loss-of-supply behavior for powered feedback devices where relevant. Confirm fail-open/closed direction, interlocks and position feedback against the offered pneumatic/electrical schematic.
How should the valve and actuator mounting interface be checked?
Confirm the mounting flange, actuator base, drive insert or coupling, stem dimensions, bracket and travel limits from the valve and actuator drawings. If the project specifies ISO 5211, state the contract edition and verify the mating dimensions; the catalog label does not prove compliance.
Are actuator accessories and spare parts included?
The catalog does not list an actuator-package bill of materials or spare-parts scope. Require the quotation to identify each accessory as included, optional or excluded. If a solenoid valve is included, specify coil supply (AC/DC), rated voltage, frequency where applicable, power/current, electrical connection and any project-required hazardous-area approval. If limit switches are included, specify contact/output type, supply requirement where applicable, electrical rating and wiring/terminal interface. If a positioner is included, identify whether it is pneumatic or electro-pneumatic. For an electro-pneumatic unit, specify the electrical input/control signal, supply requirements, feedback/output signal where required and connector/terminal interface; for a pneumatic unit, specify its pneumatic input signal and port/interface. List repair kits and seals, spring cartridges only for spring-return units, and coils/switch parts by part number and quantity.
Technical inquiry
Request a configuration review for Pneumatic Fixed Cast Steel Ball Valve
Reference this catalog identity and include the process and actuator data below. Where a drawing or datasheet defines the requirement, identify its document number and revision so the quoted configuration can be checked against the correct issue.
- Valve duty, service medium and operating frequency
- DN/NPS, bore, end connection, design/operating pressure and temperature
- Body, trim, seat and seal material grades; required test and document basis
- Actuator make/model, double-acting or spring-return execution and required fail action; control signal where an electrical control accessory is included
- Valve breakaway/running/seating-reseating torque by opening/closing direction and critical stroke position; for each value, whether a service/application margin is included and the actual included or separate margin/factor value (or calculation showing it), applicable service factors and documented manufacturer/project basis; manufacturer MAST or defined equivalent with value, units, exact valve configuration, operating-temperature range/derating and supporting basis; allowable limits for coupling, drive insert/key, actuator output interface and other torque-transmitting parts (lowest limit governs); actuator full-stroke output at minimum and maximum dynamic inlet air pressures that can reach the actuator under the offered supply/regulator arrangement, by direction and critical position; actuator maximum permitted inlet pressure and any mismatch with site maximum; for spring-return units, air-stroke output at both pressure limits and spring-stroke output separately; confirmation that minimum-pressure output meets the torque requirement with the margin applied only once and maximum-pressure output does not exceed the lowest applicable limit among MAST and all torque-transmitting components.
- Accessory bill of materials marked included, optional or excluded; where fitted, solenoid coil AC/DC supply, voltage, frequency where applicable, power and connection; limit-switch contact/output type, supply where required and rating; positioner type and input signal; for electro-pneumatic units, supply and feedback/output interface; project-required hazardous-area approvals; spare-parts part numbers and quantities, drawing revisions, inspection and certificate requirements