Skip to content

PDF-documented product

Double Ball Valve

Double Ball Valve catalog image showing a horizontal valve body with two top-mounted handwheels

The source English catalog lists this item as Double Ball Valve in the Ball Valve series (PDF page 92). The catalog image is an identity reference, not a sectional drawing: it does not show the internal flow path, seat arrangement, cavity connections or how each closure is operated. Confirm the offered configuration from a marked-up sectional drawing and flow schematic before specifying a double-isolation function.

Catalog evidence

Catalog-documented product data

Only fields stated by the PDF catalog label are shown as product data. A descriptive term such as high pressure, large diameter or ASME does not create a numeric rating, orderable range or certification claim.

FieldCatalog-documented valueEvidence status
Valve typeBall ValveVERIFIED — PDF catalog label
Catalog source seriesBall ValveVERIFIED — PDF catalog section
Catalog source pagePDF page 92VERIFIED — recovered PDF mapping

Important: values not shown in this table are intentionally unconfirmed. They must be resolved on the offered datasheet and approved order drawing.

Isolation function

Double Ball Valve does not establish DBB or DIB

VALMORA’s Ball Valve category lists Double Block and Bleed Ball Valves as a separate functional route. This catalog record is named Double Ball Valve. Without a sectional drawing, seat-direction data and cavity-bleed details, the product name and catalog image do not establish a DBB or DIB function.

How DBB and DIB are defined

Not established by this catalog entry

Engineering review

What the sectional drawing and RFQ must confirm

Do not infer the internal arrangement from the catalog illustration. Request a marked-up sectional assembly drawing and flow-path schematic, then agree on the operating sequence and acceptance basis for the exact offered configuration.

Section and flow path

Show each closure member and seat, inlet and outlet, flow arrows, internal cavities, pressure boundaries, and any bypass or equalizing passage. Identify which cavities can be pressurized in each valve position.

Operation of each closure

State whether each closure is operated independently, mechanically linked or sequenced. Identify normal positions, operating order, interlocks or locking provisions, position indication, and the manual or actuated arrangement.

Bleed, vent and drain interfaces

Mark every cavity bleed, vent or drain connection, including its location, size/rating, isolation hardware and discharge destination. State whether the ports serve separate or shared cavities and how trapped-cavity pressure is relieved.

Service and piping conditions

Provide the fluid and phase, composition and solids, design and operating pressure/temperature, differential pressure, nominal size, end connection, body and seat material requirements, orientation and piping loads.

Acceptance and inspection basis

Name the governing standard and edition, including applicable addenda/errata, and the required isolation function. Define test direction, test medium and pressure, hold time, allowable leakage, cavity-bleed verification, witness points and the records required for acceptance.

Buyer questions

Double Ball Valve questions

The catalog name identifies the product record; the sectional drawing and agreed test basis define the isolation function.

Does the name Double Ball Valve establish DBB or DIB?

No. The catalog label does not define the flow path, seat direction, pressure boundaries or cavity bleed arrangement. For projects using API 6D terminology, DBB and DIB have different pressure-source and sealing requirements. If API 6D applies, identify DIB-1 (both seats bidirectional) or DIB-2 (one unidirectional and one bidirectional seat) and the required pressure direction. Confirm the required function from the sectional drawing and project test basis.

What should the supplier’s sectional drawing show?

It should identify each closure member and seat, flow direction, inlet and outlet, pressure boundaries, cavity volumes, bleed/vent/drain ports, any equalizing or bypass passage, and the operator associated with each closure. It should also show how each closure is operated and which cavities can be vented.

How should the isolation function be accepted?

State the governing standard and edition, required isolation function, test direction, test medium and pressure, hold time, permitted leakage, cavity-bleed verification, witness requirements and the records required for the offered configuration.

Can the catalog image confirm dimensions or the internal flow path?

No. It is an identity and appearance reference only. Use the approved sectional drawing, dimensional drawing and order-specific datasheet for design, installation and acceptance.

Technical inquiry

Request a Double Ball Valve configuration review

Identify the required isolation function and reference the sectional drawing, flow schematic, closure operation, bleed interfaces and acceptance basis. Include drawing numbers and revisions where available. If a file itself needs to be transmitted, request the appropriate submission route.

Fields marked * are required.