Catalog-documented gate valve

Stainless Steel Resilient Seated Non-Rising Stem Gate Valve

Stainless steel resilient-seated non-rising-stem gate valve with a blue handwheel

The source catalog lists this gate valve as resilient seated and non-rising stem under its Hydraulic Control Valve Series. That series heading is a catalog section label, not proof of hydraulic actuation or modulating control duty. The catalog also uses “stainless steel” as a material descriptor; it does not identify the grade of every pressure-retaining or wetted component.

Product identity

What the catalog identifies

This page records one specific catalog identity within the wider Gate Valve range. It is not a complete technical datasheet: no orderable size, pressure-temperature rating, connection standard, seat compound, actuator model or project approval is established by the product name alone.

Product family

Gate Valve. This is the product type and the parent commercial route for category-level selection.

Catalog series

Hydraulic Control Valve Series. This is the source catalog section heading only; it does not establish a hydraulic operator or a control-valve function for this gate valve.

Evidence source

Recovered English product catalog, PDF page 103; the product caption is matched to its corresponding catalog illustration in the supplied image evidence.

Catalog evidence

What the source catalog actually confirms

The catalog provides product identity descriptors, not a complete valve specification. “Stainless steel” does not identify each component grade, and “resilient seated” does not identify the elastomer compound, seat construction or leakage acceptance.

FieldCatalog wordingWhat it confirms
Product identityStainless Steel Resilient Seated Non-Rising Stem Gate ValveExact product label on PDF page 103
Valve typeGate ValveProduct label
Stem arrangementNon-rising stemProduct caption; operator and position indication are not specified
Seat descriptorResilient seatedProduct label; elastomer compound and seat construction are not specified
Material descriptorStainless steelProduct label; component grades and material allocation are not specified
Catalog sectionHydraulic Control Valve SeriesSection heading only; not proof of hydraulic actuation or control duty

Before quotation: obtain the offered datasheet and approved drawing for size, pressure-temperature limits, end details, material grades, seat system, operator and test requirements. None of those values should be inferred from the catalog image or section heading.

Evidence boundary

Confirmed descriptors and open configuration fields

The product name confirms a gate valve with a non-rising-stem arrangement and a resilient-seat descriptor. The catalog also labels the material as stainless steel. The detailed construction and operating limits remain configuration-specific.

Confirmed by the catalog

Confirm before quotation

Engineering review

How to specify this non-rising-stem, resilient-seated gate valve

The two defining terms in this catalog name affect different parts of the purchase decision: the stem arrangement determines how the gate is operated and accessed; the resilient-seat description makes the seat compound and shutoff criteria important. Confirm both against the actual service and offered sectional drawing.

Duty and service medium

Specify the line function and whether the valve is for full-open/full-closed isolation; state required shutoff performance and operating frequency. Identify the plant/equipment duty and provide fluid composition and concentration, phase, solids or abrasives, cleaning/disinfection chemicals and corrosion or erosion concerns. If routine flow modulation is required, do not infer control capability from the catalog series heading; evaluate a suitable control-valve design.

Pressure and temperature

Provide DN/NPS, design and operating pressure, maximum differential pressure during opening and closing, and minimum, normal and maximum temperature. Include relevant start-up, shutdown, vacuum or other transient conditions. The catalog supplies no pressure class or pressure-temperature rating for this item.

Materials, resilient seat and end connections

“Stainless steel” is a catalog descriptor, not a complete material schedule. Identify the required grades for the body, bonnet, stem, gate/wedge core, trim, fasteners and other wetted parts. Confirm the actual seat/elastomer compound, wedge coating or encapsulation/seat-ring construction, compatibility with the medium and temperature, required shutoff direction and leakage acceptance, and any potable-water or process-contact approvals. Separately specify the end type, flange standard and facing (or other mating interface), pressure rating and face-to-face dimensions.

Non-rising stem drive and installation

In a conventional non-rising-stem arrangement, the stem rotates without external axial travel while the gate moves along the stem threads. Confirm the offered stem/nut arrangement, handwheel, operating nut, gearbox or actuator, opening direction, number of turns, required torque/thrust, position indicator and mounting interface. The catalog illustration shows a handwheel but does not confirm the supplied operator. Check any valve-box or stem-extension needs, overhead clearance, orientation, flow-direction marking, piping loads, ambient exposure and maintenance access. If powered, define the utilities, control interface and any required loss-of-power action.

Testing and documents

Request the configuration-specific datasheet, general-arrangement and sectional drawings, material schedule/traceability, shell and seat leakage tests with acceptance criteria, stem-sealing and bonnet-gasket details, applicable design/test standards and editions, inspection plan, witness/hold points and required certificates. Ask which records will be supplied for the quoted configuration and purchase order.

Buyer questions

Stainless Steel Resilient Seated Non-Rising Stem Gate Valve FAQ

These answers separate the source catalog descriptors from the technical details that must be confirmed for the offered valve.

What does the source catalog confirm for this gate valve?

It identifies a Gate Valve named Stainless Steel Resilient Seated Non-Rising Stem Gate Valve. The product caption specifies a non-rising stem, the name includes a resilient-seat descriptor and a stainless-steel material descriptor, and the entry appears under the Hydraulic Control Valve Series heading. The catalog does not provide a complete datasheet.

Does “Hydraulic Control Valve Series” mean this gate valve is hydraulically actuated?

No. It is the source catalog section heading. It does not establish a hydraulic operator, an actuator model or a modulating control function. Confirm the offered operator and duty separately; a conventional gate valve is generally selected for on/off isolation rather than routine throttling.

What does non-rising stem mean for operation?

In a conventional non-rising-stem arrangement, the stem rotates without moving axially outside the valve while the gate travels along the stem threads. This can reduce the external stem-travel envelope, but the actual stem/nut design, operator, opening direction, turns, torque or thrust, position indicator and access arrangement still need confirmation.

What does resilient seated confirm about the seal?

It identifies a resilient-seat design descriptor only. The catalog does not specify the elastomer compound, wedge coating or encapsulation method, seat-ring construction, replaceability, chemical compatibility, sealing direction or leakage acceptance. Obtain these details from the offered material schedule, drawing and test specification.

Can the catalog illustration be used as a dimensional or connection reference?

No. The illustration supports product identity and general appearance only. Use the approved general-arrangement and connection drawings for face-to-face dimensions, flange drilling/facing, installation clearances and mating-pipe checks.

What should be included in the RFQ?

Provide the valve duty and fluid composition/concentration, solids and cleaning chemicals, size, design pressure, maximum operating differential pressure, temperature range, end connection, material grades, seat compound and leakage criteria, NRS operator/drive requirements, quantity, drawings, tests, inspection and document requirements.

Technical inquiry

Request a configuration review for Stainless Steel Resilient Seated Non-Rising Stem Gate Valve

Reference this catalog identity and provide the operating case. The quotation should identify the actual body and trim grades, resilient-seat compound, end connection and non-rising-stem drive offered, with the applicable drawings and test/document scope.