Skip to content

PDF-documented product

Stainless Steel Resilient Seated Rising Stem Gate Valve

Catalog image of the stainless steel resilient-seated rising-stem gate valve, showing a handwheel, exposed stem and flanged ends.

The source English catalog lists this item as Stainless Steel Resilient Seated Rising Stem Gate Valve on PDF viewer page 103 (printed spread 195–196). It appears under the Hydraulic Control Valve Series, while the product type is explicitly Gate Valve. The image depicts a handwheel and exposed stem; it is not an order drawing.

Product identity

Product identity and catalog context

This page represents one documented catalog identity. It does not replace the parent product category and it does not claim an unverified model, rating or project history.

Product family

Gate Valve. This is the product family and the parent category for browsing other gate-valve constructions.

Catalog series

Hydraulic Control Valve Series. This is the source catalog section heading. The current VALMORA Gate Valves range lists this product among general isolation entries; the catalog heading does not establish a modulating control-valve duty.

Evidence source

Recovered English product catalog, PDF viewer page 103 (printed spread 195–196); mapped image AST-R1-0365.

Catalog evidence

Catalog-documented product data

Only the fields explicitly stated by the source catalog are listed as confirmed. The stem descriptor does not specify gate geometry, and the resilient-seat wording does not identify an elastomer grade or sealing arrangement.

FieldCatalog-documented valueEvidence status
Valve typeGate ValveVERIFIED — PDF catalog label
Stem arrangementRising stemVERIFIED — product name and catalog label
Material descriptorStainless steelVERIFIED — catalog label only; grade not stated
Catalog section headingHydraulic Control Valve SeriesVERIFIED — printed catalog section heading
PDF referenceViewer page 103 (printed spread 195–196)VERIFIED — recovered PDF mapping

The catalog does not state the gate/closure geometry, seat compound, pressure class or pressure-temperature limits, size range, end standard, operator, dimensions, cycle duty or test basis. Confirm each against the datasheet and approved order drawing for the offered configuration.

Evidence boundary

Known facts and open configuration fields

The PDF establishes catalog identity and the pictured external arrangement. It does not show internal gate/closure geometry or prove resilient-seat material, component grades, pressure-temperature envelope, dimensional schedule, cycle rating or complete operator assembly.

Confirmed by the catalog

Confirm before quotation

Engineering review

Specify the valve against its actual duty

The catalog establishes a gate-valve identity and a rising-stem arrangement, not an order-ready specification. These inputs determine whether the offered construction, seat and operator match the service.

Valve duty

Treat this entry as an isolation candidate: gate valves are normally used fully open or fully closed, not for routine throttling. State the required duty, any partial-opening or modulating requirement, expected operating cycles and shutoff/leakage acceptance. If throttling is required, obtain written manufacturer approval for this exact design.

Operating envelope

Provide nominal size, design and operating pressure, maximum differential pressure during opening/closing, minimum/normal/maximum temperature and any surge or vacuum cases. The catalog gives no rating; request the pressure–temperature limits for the offered size and material.

Materials and connection

Stainless steel is a catalog material descriptor, not a grade or full component schedule. Confirm body, bonnet, stem, gate/closure member, resilient seat/seal and packing materials, then check compatibility with the medium. Specify end type, flange facing or other interface, dimensional standard and mating pipe dimensions.

Actuation requirement

The image depicts a handwheel, but it does not confirm the supplied operator or available options. State the required drive/operator type: manual, geared, electric, pneumatic or hydraulic, as applicable. For a powered arrangement, specify the required control mode (local/remote), available utilities and control signal/interface. State any required fail action and opening/closing time; request confirmation of turns/stem travel and torque or thrust at the stated differential pressure.

Inspection and documents

Request the approved GA drawing and datasheet for the quoted size and configuration, including face-to-face dimensions and full-open overall height. Identify the project-required material certificates, any applicable compliance or inspection certificates and approval documents. Also state pressure/seat test acceptance, inspection points, marking and any third-party witness or hold points. Ask the supplier to confirm which documents are available for the quoted configuration; this request does not establish that a certificate or approval is already held.

Application boundary

Match the valve to the service and installation

Final suitability depends on the fluid, required shutoff, operating envelope, seat compatibility and the installed stem/operator envelope—not on the catalog name alone.

Service medium

Provide fluid composition, concentration, phase, solids, temperature, corrosion/erosion risks and cleaning chemicals. State the project-specified corrosion allowance separately, if applicable; do not infer an allowance from the stainless-steel catalog descriptor. “Resilient seated” does not identify the elastomer compound or prove compatibility; confirm the offered seat and stem-seal materials against the medium.

Industry and system

Identify the line function, upstream/downstream equipment and isolation sequence, including any bypass requirement. The plant or industry name alone does not establish the valve’s duty or material suitability.

Installation boundary

A rising stem provides visible travel indication and moves upward as the valve opens, so allow vertical clearance for full travel plus the handwheel or drive envelope. Confirm full-open height, mounting orientation, flow direction, piping loads and flange alignment from the approved GA drawing. Also state the site ambient/environmental conditions and intended maintenance method, and verify packing/bonnet service access and removal space. If headroom is limited, compare the non-rising-stem entry and verify its own position-indication and maintenance requirements.

Buyer questions

Questions about the rising-stem gate valve

The catalog confirms a limited product identity. The questions below separate those facts from the information needed to specify and quote the offered assembly.

What does the catalog actually confirm?

It names the product as Stainless Steel Resilient Seated Rising Stem Gate Valve and lists it under the Hydraulic Control Valve Series. The catalog confirms the Gate Valve, Rising Stem and Stainless steel descriptors; it does not specify gate geometry, component grades, seat compound, pressure rating, dimensions, operating frequency or the supplied operator.

Which details must be confirmed before quotation?

Confirm the gate/closure geometry; body, bonnet, stem, gate, seat and packing grades; seat compound and medium compatibility; project-specified corrosion allowance, if applicable; pressure-temperature limits and maximum differential pressure; size, end connection, standard and edition; full-open height; required drive/operator type (manual, geared, electric, pneumatic or hydraulic, as applicable), available utilities, control mode and control signal/interface for powered arrangements; turns, torque/thrust and cycle duty; site ambient/environmental conditions and intended maintenance method; shutoff acceptance; and the project-required material certificates, applicable compliance/inspection certificates, approval documents, tests and witness points. Ask the supplier to confirm document availability for the quoted configuration.

Can the catalog image establish dimensions or installation clearance?

No. It is an identity and appearance reference, not a GA drawing. The rising stem needs room for its full travel and operator envelope; the image cannot establish pressure rating or operating frequency. Use the approved drawing and datasheet to check full-open height, face-to-face dimensions and service access.

What should an RFQ include?

State the valve duty, medium, size, design/operating pressure, maximum differential pressure, temperature range, end connection, materials and seat requirements; any project-specified corrosion allowance; required drive/operator type (manual, geared, electric, pneumatic or hydraulic, as applicable), available utilities, control mode and control signal/interface for powered drives; expected cycles and shutoff/leakage criteria; site ambient/environmental conditions and intended maintenance method; quantity; and project-required material certificates, applicable compliance/inspection certificates, approval documents, drawings, tests and witness points. Ask the supplier to confirm which documents are available for the offered configuration.

Technical inquiry

Request a configuration review

Reference this catalog identity and provide the known service data below. The offered gate construction, seat materials, pressure-temperature limits, operator and documentation scope must be confirmed against the project specification; unknown fields should remain open until stated in the quotation.

Fields marked * are required.