Electric Butterfly Valve

Electric Butterfly Valve — catalog photograph

The source catalog names this product Electric Butterfly Valve and shows electrically operated butterfly-valve assemblies. For a workable quote, the valve body, sealing arrangement and electric actuator must be specified together—not selected from the photograph alone. Start with the required on/off or positioning duty, then establish maximum differential pressure, torque, electrical controls and the required response to power loss.

START WITH THE OPERATING TASK

Choose the valve–actuator duty before comparing models

Electric actuation describes how the butterfly valve is driven, not its shutoff performance, control accuracy or emergency behavior. These are separate configuration decisions. The supplied catalog identifies a product type but does not publish an order-ready specification for either pictured assembly.

On/off isolation

For commands such as OPEN and CLOSE, start with a quarter-turn on/off arrangement. Specify the number of operating cycles, allowable full-stroke time, required closed-position leakage performance and any local/manual operation requirements. A low-cycle switch-duty actuator must not be assumed adequate for frequent positioning.

Positioning or throttling

If the control system needs occasional intermediate positioning, specify positioning duty and the required command and feedback interface. If it must frequently adjust flow, confirm the valve is suitable for throttling and specify an actuator rated for modulating duty with appropriate feedback. Check operating frequency, allowable starts and control stability; a simple open/close motor does not become a modulating package merely by adding an analog signal.

Emergency or critical service

Define what the valve must do when the supply fails, a command is lost or an emergency shutdown signal is asserted. Fail-open, fail-closed and stay-in-place are different requirements. Electric drive alone does not guarantee any one of them. A confirmed fail-to-position solution may require stored energy or another qualified actuator system.

Catalog evidence

What the original product catalog actually confirms

The original English catalog labels several photographs Electric Butterfly Valve on physical PDF pages 94–95 (printed pages 177–180). They show different operator appearances but give no single transferable body/actuator BOM or selection envelope. Neither the cast markings nor the wider series introduction establish an offered size, pressure, material or motor rating for this product.

FieldWhat can be statedEvidence / next step
Product identityElectric Butterfly ValveSOURCE CATALOG LABEL
Product familyButterfly ValveSOURCE CATALOG HEADING
Drive categoryElectricSOURCE CATALOG LABEL; no electrical specification
Image sourcePDF physical pages 94–95 (printed 177–180)TWO LABELED ILLUSTRATIONS; not an approved GA drawing
Size / pressure / temperatureNot established for this offered assemblyREQUIRES OFFERED VALVE DATASHEET
Body / disc / seat / connectionNot established for this offered assemblyREQUIRES OFFERED VALVE DRAWING AND MATERIAL SCHEDULE
Actuator torque / supply / controlsNot established for this offered assemblyREQUIRES MATCHED ACTUATOR DATASHEET
Leakage, standards and testingNot established for this offered assemblyREQUIRES APPLICABLE PROJECT SPECIFICATION AND OFFERED RECORDS

For a technical or purchase order release, request the offered combination drawing and individual valve and actuator datasheets. Catalog photographs are not fabrication dimensions, torque curves or proof of required certificates.

ELECTRICAL AND CONTROL INTERFACES

Specify commands, feedback and power-loss behavior separately

The control interface determines how the DCS/PLC commands and verifies valve motion. The fail response determines what happens without a healthy command or power supply. These requirements must appear on the same actuator data sheet and wiring drawing; the catalog provides neither.

Normal control and indication

Loss of supply, signal or ESD

MATCHED ASSEMBLY ENGINEERING

Size the electric actuator against the valve—not only the pipe

For an electric butterfly valve the decisive selection input is the valve operating torque across its full travel under the stated service conditions. Nominal pressure class or actuator motor wattage alone cannot establish a reliable pairing. Request one matched assembly schedule rather than separate uncoordinated product quotations.

1. Maximum differential pressure and torque

Provide the maximum differential pressure across the disc while opening, closing and, if relevant, throttling—not just line design pressure. Include any applicable pressure transients, vacuum conditions or reverse differential-pressure cases in the duty data. Request break-to-open, running, seating/reseating and any significant flow-induced dynamic torque for the specified valve, seat and temperature. Select actuator output and reserve from the manufacturer’s operating torque data, including low-voltage/ambient derating and the valve’s allowable stem torque; no universal margin or torque value is assumed here.

2. Stroke, starts and operating time

Specify required quarter-turn travel, allowed opening/closing time, number of full strokes per day and positioning starts per hour. A frequently adjusted control valve needs a suitable modulating-duty rating and heat-management allowance; a slow shutoff stroke can also be unacceptable in a time-critical system. Ask the supplier for the actuator’s duty classification and permissible operating schedule.

3. Valve-to-actuator coupling

Match the valve drive stem, mounting flange/bolt pattern, coupling and bracket arrangement to the offered actuator, together with travel stops and torque/limit settings. Specify an applicable interface standard only if required by the project and verify it on the offered drawings; the catalog does not establish ISO 5211 conformity for this item. The support arrangement must carry actuator weight and site loads.

4. Site power, control and enclosure

Provide the panel supply, DCS/PLC command type, discrete/analog feedback, alarm contacts, cable entry, local/remote selector and manual override needs. State ambient temperature, rain, dust, washdown, corrosive atmosphere and any classified hazardous area. Request the specific enclosure rating, certification (if necessary), wiring diagram and usable controls for the quoted actuator; none is inherent in the word “electric.”

5. Release package and maintenance access

Before purchase approval, request a valve-and-actuator GA drawing, seat/pressure-temperature data, torque selection basis, actuator wiring and controls, operating manual, mechanical stop settings, maintainable access envelope and the pressure/leakage test or inspection records specified for the project. Confirm whether requested material certificates and specified material marking/traceability, third-party witness inspection where required, spares and FAT are included in the supplier’s actual scope.

VALVE BODY AND INSTALLATION

Check seat suitability and the disc’s full sweep

Once electric controls are defined, confirm the mechanical valve itself can meet the process duty. The actuator cannot compensate for an unsuitable seat material, inadequate shutoff specification or interference between a rotating disc and the adjacent pipework.

Fluid, seat and allowable leakage

Provide fluid composition, temperature extremes, solids/abrasion, corrosion potential, flow direction and the required shutoff leakage criterion. Ask the supplier to identify the actual body, disc, shaft and seal materials and show their relevant pressure-temperature limits. A butterfly valve described as “electric” does not imply soft-seated, metal-seated, bidirectional shutoff or control-service suitability.

Flange fit and disc clearance

Supply mating pipe/flange dimensions, required face-to-face, end connection, gasket strategy and nearby liner or spool geometry. The disc may extend beyond the valve body during travel: check the full opening sweep against pipe bore, flange, liner and adjacent fittings using the approved dimensional drawing, not the catalog photograph. Installation instructions must govern final fit-up and bolting.

Mounting, service access and failure handling

Confirm flow/shaft orientation where the valve design requires it, actuator and handwheel access, overhead clearance, lifting points, cable routing and protection against pipe loads. If shutdown position is safety-critical, require a documented loss-of-power test plan for the offered assembly; do not treat manual override or the mere presence of a motor as evidence of fail-safe operation.

Buyer questions

Questions that prevent the wrong actuator order

These distinctions are useful during order clarification. Actual electrical and valve performance must be stated in the proposed equipment documents.

Is this Electric Butterfly Valve already specified for modulating control?

No. The source catalog confirms electric operation only. For modulating duty, request a suitably rated positioning actuator, control input and position feedback together with the permitted starts and cycle duty.

Will the valve automatically close if electrical power fails?

Not necessarily. The required fail-closed, fail-open or stay-in-place response—and the separate response to signal loss—must be specified and supported by the selected actuator and control system.

Can a catalog image establish the valve diameter or pressure rating?

No. Photos and casting marks do not replace the offered datasheet, assembly drawing, applicable pressure-temperature limits and documented test scope.

What belongs in the electric butterfly valve RFQ?

State on/off or modulating duty; fluid and temperature; size and connection; normal/design pressure and maximum differential pressure; leakage target; supply and controls; failure response; stroke time and starts; quantity; and required drawings, tests and documents.

Technical inquiry

Request a matched electric butterfly valve quotation

Send the valve duty, process envelope and actuator controls so VALMORA can review a matching assembly. Buyer inputs: medium, size/connection, required pressure class or rating, operating and design conditions, maximum differential pressure, shutoff or control duty, available power, requested command/feedback, loss-of-power response, cycle rate, quantity, required delivery date and project documents. Supplier to confirm in writing: exact body/seat/drive design, valve torque basis, actuator rating and model, GA/wiring drawings, test/document scope, quoted price, expected lead time and other commercial terms. No unspecified option is included by assumption.