Skip to content

Catalog-listed product

A902Y Safety Relief Valve

A902Y Safety Relief Valve catalog image

The recovered English supplier catalog identifies A902Y as a Safety/Relief Valve in the Safety Valve series (PDF page 105). It provides a product illustration, not a model-specific datasheet or relieving-capacity schedule. Use this page to identify the catalog entry and prepare the relief-duty information needed for a configuration review.

Catalog evidence

A902Y product identity

The recovered supplier catalog confirms the product name, valve-family label and source series. It does not publish the technical values needed to size, rate or approve a relief device. The table separates documented identity from the information that must be established for the offered configuration.

Catalog evidence and configuration fields

FieldCatalog evidenceWhat must be confirmed
Product nameA902Y Safety Relief ValveCatalog identity only
Valve-family labelSafety/Relief ValveCatalog label; not a complete design description
Source seriesSafety ValveCatalog section heading
Set pressure and rated relieving capacityNot stated on the recovered catalog pageConfirm the proposed set pressure, required relieving load and rated capacity for the exact offered configuration
Construction, orifice and accessoriesNot stated on the recovered catalog pageObtain the model-specific construction details, orifice designation or area and any applicable pilot, balancing or lever arrangement
Fluid and pressure-temperature limitsNot stated on the recovered catalog pageCheck the offered valve against the actual fluid phase, composition and operating/relieving conditions
Materials, size and connectionsNot stated on the recovered catalog pageConfirm body, trim and seat materials, inlet/outlet sizes, end type, rating, facing and dimensions from the datasheet and drawing
Backpressure limitsNot stated on the recovered catalog pageProvide superimposed and built-up backpressure; obtain the allowable limits for the offered design
Code and certificationNot stated on the recovered catalog pageState the governing jurisdiction and code edition; request evidence applicable to the exact offered valve

Selection boundary: A model name, inlet size or catalog image is not a capacity rating. The required relieving load comes from the protected equipment’s relief basis; the offered valve’s rated capacity must then be evidenced for the specified fluid and relieving conditions.

Engineering review

What must be confirmed before selecting A902Y

A902Y is a catalog identity, not a completed relief specification. The protection engineer defines the required duty; the supplier must show that the proposed configuration can meet it. Provide the protected-equipment limit, credible relief case, required capacity, set-pressure basis, fluid and relieving conditions. Do not apply a generic operating-to-set margin without checking the exact valve design.

Backpressure has two components: superimposed backpressure is already present before the valve opens; built-up backpressure develops as flow passes through the discharge system. For a common header, provide its minimum/maximum pressure and possible simultaneous relieving cases. The effect on opening, capacity and stability depends on the exact design.

Relief-duty selection inputs

Buyer / protection engineer provides

Supplier to confirm for the offered valve

Service, installation and document requirements

The buyer should identify the actual service: fluid concentration and phase, solids or contaminants, corrosion or erosion exposure, cleaning requirements, and required wetted-part and seat/seal materials. These are project inputs, not confirmed A902Y material grades or fluid-compatibility claims.

Provide the intended flow direction, mounting or orientation constraints, piping/nozzle loads, ambient exposure, available clearances and maintenance access. Request verification of the offered valve’s installation requirements and allowable loads against its dimensional drawing and installation, operation and maintenance (IOM) instructions; the catalog image establishes none of these limits. If vacuum protection is required, identify it separately—the A902Y catalog record does not establish vacuum-service suitability.

Specify the required documentation and acceptance scope in the inquiry: material certificates, pressure and leakage test records, inspection and marking requirements, and third-party witness points where applicable. Request written confirmation of which records and witness arrangements can be provided for the offered configuration.

Buyer questions

A902Y Safety Relief Valve: technical questions

These answers distinguish catalog identification from the evidence needed for a project-specific relief selection.

Does the catalog publish an A902Y set pressure or rated capacity?

No. The recovered catalog page identifies the A902Y name, valve-family label and source series, but it does not state a set pressure, orifice size or rated relieving capacity. These must be confirmed from model-specific documents against the project's relieving conditions.

What backpressure information should I provide?

Provide both superimposed backpressure present before the valve opens and built-up backpressure generated during discharge. State whether superimposed pressure is constant or variable; for a shared header, include its pressure range and other devices that may relieve at the same time. The effect on opening, capacity and stability depends on the exact valve design.

Which code approvals or certificates are confirmed for A902Y?

None are identified in the recovered catalog evidence. Specify the governing code, edition and jurisdiction, then request documentation that applies to the exact offered model and configuration.

Can the catalog image confirm dimensions or installation?

No. It supports catalog identity and visible appearance only. Use the model-specific dimensional drawing and installation instructions to check interfaces, orientation, clearances and piping requirements.

Technical inquiry

Request an A902Y configuration review

Use A902Y as the catalog reference and provide the relief-design basis. If the set pressure, required capacity or code basis is still being developed, mark it as pending rather than estimating it. Ask the supplier to confirm the offered construction, rated capacity, connections and approval scope against the submitted duty.

Fields marked * are required.