Catalog-listed product
Ceramic Knife Gate Valve
The supplier catalog lists this item as a Ceramic Knife Gate Valve in the Knife Gate Valve series (PDF page 108). It identifies the valve type and the catalog designation “Ceramic” only; it does not identify the component(s) to which that designation applies or specify a ceramic grade. Operating limits, connection and seat directionality are also not stated. Confirm the offered construction against its sectional drawing and datasheet before selection.
- Valve type: Knife Gate Valve
- Catalog designation: Ceramic
Catalog details
Catalog listing
The table below lists the product type, catalog designation and page reference shown in the supplier catalog. It is not a dimensional, pressure or component-material specification.
| Field | Catalog entry | Catalog reference |
|---|---|---|
| Valve type | Knife Gate Valve | Catalog product label |
| Catalog designation | Ceramic | Product-name designation |
| Catalog series | Knife Gate Valve | Series heading |
| Catalog page | PDF page 108 | PDF page reference |
Not stated in this catalog record: size, pressure / temperature limits, end connection, ceramic grade or sealing direction. Use the offered datasheet and approved drawing for those values; do not infer lining coverage from the illustration.
What the catalog does not specify
What to confirm before selection
The catalog identifies the product by type and name, but it does not provide a complete bill of materials or operating envelope. “Ceramic” is part of the catalog product name; the catalog does not say whether the body, gate, seat or full flow passage is ceramic-lined.
What is listed in the catalog
- Valve type: Knife Gate Valve — listed as the valve type in the catalog; the full construction is not shown.
- Catalog designation: Ceramic — included in the product name; component location and grade are not specified.
Confirm before quotation
- Ceramic scope: component locations, grade and the complete wetted-material schedule.
- Process duty: medium composition, solids profile, temperature and cleaning conditions.
- Sealing: flow direction, required shutoff direction(s), allowable differential pressure and leakage acceptance.
- Configuration: size, connection, actuation, dimensions, inspection, tests and required documents.
Engineering review
How to specify the Ceramic Knife Gate Valve
A comparable quotation must identify the ceramic scope, process solids, seat direction and pressure differential for the same operating case. Use the following inputs to review the exact offered build.
Valve duty and shutoff
State whether the valve is for on/off isolation, bypass, emergency isolation or throttling / modulating service. Give the normal and upset cycle frequency and the required shutoff or leakage acceptance. If throttling is intended, obtain explicit confirmation that this knife gate construction is designed for that duty.
Operating envelope and differential pressure
Provide design and operating pressure, minimum / normal / maximum temperature, and upstream and downstream pressures for normal operation, startup / shutdown and the closed condition. State the maximum differential pressure across the valve during opening, closing and shutoff, including credible transients and any vacuum case. Line pressure alone is not a substitute for differential pressure.
Ceramic materials and connections
Request a sectional drawing and component-by-component material schedule. Identify whether ceramic is used on the gate / knife, seat, body bore or liner, wear inserts, or another location; specify its grade and the materials of the remaining wetted parts. Confirm DN / NPS, end type, flange standard and facing, face-to-face dimensions and mating interface.
Actuation requirement
State manual, gear, electric, pneumatic or hydraulic preference, operating cycles, available utilities, required travel time, control signals and fail action. Ask the supplier to size and confirm the actuator against the maximum differential pressure, seat load and actual solids duty—not nominal size alone.
Inspection and documents
List the required sectional and dimensional drawings, datasheet, ceramic and other material records, pressure / leakage test basis, inspection points, marking and any third-party witness requirements. Confirm which documents can be supplied for the exact quoted configuration and revision.
Application boundary
Match the catalog identity to the real service
A ceramic component can only protect the surfaces where it is actually installed. Suitability also depends on the rest of the wetted assembly, the seat arrangement and how solids behave during valve travel and shutdown. The catalog does not establish these details for this product.
Abrasive slurry and wear surfaces
If the application is abrasive slurry, confirm that the ceramic is located at the surfaces exposed to the relevant particle impact or sliding contact. Provide particle size, hardness, shape, solids loading and line velocity, then ask for the ceramic grade, component coverage and any impact or operating limits. The catalog label alone does not establish whole-flow-path wear protection or slurry suitability.
Corrosive or chemically aggressive media
Provide the fluid composition, concentration, pH, temperature and cleaning chemicals. Check the ceramic grade and each other wetted material separately, including the body, gate, seat and seals. A ceramic descriptor does not establish chemical compatibility of the complete valve assembly.
Settling, fibrous solids and installation
If solids settle, pack or dry during shutdown—or fibers can bridge—state whether the gate must close through the material and whether deposits can collect around the seat or in body cavities. Request the proposed clearance, seat / cavity arrangement, flushing or drain provisions and maintenance access. Also confirm orientation, flow arrow, piping loads and actuator removal space.
Related product routes
Compare documented alternatives before RFQ
Use the parent category for commercial selection and these related catalog records for identity-level comparison. No page inherits specifications from another product.
Electric Ceramic Knife Gate Valve
Separate electric-actuated catalog identity. Review its own ceramic scope, actuator and operating data; specifications from this page do not transfer.
New Type Knife Gate Valve
Separate catalog identity. Request its own sectional drawing and confirm the construction rather than relying on the product name alone.
Electric Stainless Steel Knife Gate Valve
Separate stainless-steel / electric catalog identity. Confirm its material grade, wetted surfaces and actuator details from its own datasheet and sectional drawing.
Buyer questions
Ceramic Knife Gate Valve FAQ
These answers distinguish the catalog label from the component, process and pressure data needed to select the offered valve.
What does the catalog confirm for this product?
It identifies a Ceramic Knife Gate Valve in the Knife Gate Valve series and lists “Knife Gate Valve” as the valve type and “Ceramic” as the catalog designation on PDF page 108. It does not state a size, pressure rating, ceramic grade, component location, connection or sealing direction.
Does “Ceramic” mean the whole flow path is ceramic-lined?
No. The catalog does not show whether ceramic is applied to the gate / knife, seat, body bore or liner, wear inserts or another component. Request a sectional drawing and full wetted-material schedule before assuming any lining coverage or material grade.
What solids data should I provide for slurry service?
Provide the medium and carrier liquid, solids concentration by weight and / or volume, d50 and maximum particle size, particle hardness, shape and density, viscosity, temperature, line velocity and whether solids settle or dry during shutdown. State the cleaning or flushing method. Weight-percent and volume-percent are different concentration bases.
How should sealing direction and differential pressure be specified?
Show the normal flow direction and give upstream / downstream pressures for operation and shutoff. State whether the valve must seal against pressure from one side or both, including reverse-flow or dead-end cases. Provide maximum differential pressure during gate travel and in the closed position, and request the seat rating for each required direction.
Technical inquiry
Request a configuration review for Ceramic Knife Gate Valve
Reference this catalog identity and provide the process conditions that determine ceramic scope, seat selection and actuator sizing. Mark unknown items for confirmation rather than assigning assumed values. VALMORA can then review the offered configuration, documentation scope and commercial terms.
- Ceramic component locations, grade and full wetted-material schedule
- Medium composition, solids concentration basis, particle size / hardness / shape and settling behavior
- Normal flow direction, required shutoff direction(s), upstream / downstream pressure and maximum differential pressure
- DN / NPS, end connection, operating / design pressure and temperature range, plus any project-specified PN/Class or equivalent pressure designation, if defined
- Valve duty, cycle frequency, actuator preference, available utilities and cleaning requirements
- Quantity, required drawings, datasheet, material, test and inspection documents
- Project-specified valve design and test standards, including required editions / revisions; if not defined, state the standards proposed for the offered configuration
- Any project-specified corrosion allowance, where applicable to the proposed construction