Catalog-identified product
Socket Weld Globe Valve
The supplier product catalog identifies this item as Socket Weld Globe Valve on PDF page 112. It confirms the valve type and socket-weld connection label; the offered size, pressure–temperature limits, material grades, trim and applicable standards still require configuration-specific documents.
- Valve type: Globe Valve
- End connection: Socket weld
Product identity
What this catalog record identifies
This page identifies one supplier-catalog entry, not a complete order specification. Use the existing Globe Valves category link for family-level selection; use this record to review the documented Socket Weld Globe Valve identity and define the exact project configuration for quotation.
Product family
Globe Valve. This is the product family identified by the catalog label; it does not establish a particular flow characteristic or continuous-control capability.
Catalog series
Forged Steel Valve. This is the source-series heading printed in the supplier catalog, not a confirmed material grade or a complete statement of the offered body construction.
Evidence source
Recovered supplier English product catalog, PDF page 112. The catalog illustration supports product identity and appearance only.
Catalog evidence
Catalog-documented product data
Only fields stated by the supplier catalog are listed as documented product data. The source-series heading is not a material specification, and the product name does not establish a size, pressure class, temperature limit, valve trim, flow coefficient or certification.
| Field | Catalog-documented value | Evidence status |
|---|---|---|
| Valve type | Globe Valve | VERIFIED — PDF catalog label |
| Connection | Socket weld | VERIFIED — PDF catalog label |
| Catalog source series | Forged Steel Valve | VERIFIED — PDF catalog section |
| Catalog source page | PDF page 112 | VERIFIED — recovered PDF mapping |
For quotation: obtain the offered datasheet and dimensioned end-connection drawing. Confirm the material schedule, pressure–temperature basis, internal trim, flow data and applicable design / test requirements for the exact configuration; do not infer them from the catalog title or image.
Evidence boundary
What is documented—and what remains open
The catalog confirms the product label, source-series context and mapped appearance. It does not provide a complete bill of materials, operating envelope, dimensional drawing, valve performance data or order-ready compliance record.
Confirmed by the catalog
- Valve type: Globe Valve — stated in the product label.
- Connection: Socket weld — stated in the product label.
Confirm for the offered configuration
- Duty and flow: isolation or throttling, operating frequency, required shutoff, flow range and pressure drop.
- Operating envelope: medium, phase, design / operating pressure, temperature range and transients.
- Materials and trim: body / bonnet grade, disc or plug, seat, stem, packing, gaskets and wetted parts.
- Socket-weld interface: nominal size, pipe outside diameter, wall / schedule, line class and end dimensions.
- Operation and installation: manual or powered operator, utilities, flow direction, orientation and access.
- Project verification: applicable codes / editions, welding documents, inspection, testing and traceability.
Engineering review
What to specify before requesting a quote
A useful RFQ links this catalog identity to one defined operating case and one piping interface. Send the values together so the offered valve, trim, socket-weld ends and inspection scope can be reviewed against the same project requirements.
Valve duty and operating method
State whether the valve is for line shutoff, intermittent manual throttling or continuous modulating control. Include operating frequency and the required seat-leakage criterion. A globe-valve label does not prove that this entry is a sized control valve; continuous modulation needs a model-specific sizing and actuator review.
Flow rate and pressure drop
Provide minimum, normal and maximum flow with inlet and outlet pressure for each case, plus fluid phase, temperature and relevant fluid properties (including vapor pressure for liquid service where needed). For modulating duty, request the offered trim’s Cv / Kv and flow characteristic versus travel at the required operating range. If differential pressure is significant, ask whether cavitation, flashing, noise or erosion could limit the duty; no flow coefficient is established by this catalog entry.
Operating envelope, materials and trim
Identify the fluid composition, concentration, phase, solids, corrosion / erosion risks and cleaning conditions. State design pressure and design temperature separately from the operating pressure range and minimum / normal / maximum operating temperatures; identify pressure surges / transients or vacuum conditions where applicable. If the project already specifies a valve pressure class or rating basis, include it for review. Request the body / bonnet material grade and a component-level schedule for the disc or plug, seat, stem, packing, gaskets and wetted parts; the supplier must confirm the pressure–temperature limits for the offered construction.
Socket-weld piping and installation
Provide pipe NPS / DN, outside diameter, wall / schedule, piping class and the valve’s controlled end drawing. Confirm the mating dimensions before prefabrication. Also state flow direction, installation orientation, operator clearance, support, piping loads and maintenance access; the catalog image is not a dimensional reference.
Welding, inspection and documents
Identify the governing project piping code and edition and the welding procedure specification (WPS) approved for the work. Request procedure-qualification evidence permitted by that code and edition, including a supporting PQR where required. A standard WPS or procedure qualification by others is an alternative only where expressly permitted and approved for the project. Obtain welder performance-qualification records where required. Confirm filler compatibility, any required preheat or post-weld heat treatment, weld examination, valve pressure and seat-leakage tests, piping-system test boundaries, material traceability and witness points. Follow the approved valve IOM and project procedure; this catalog does not specify a welding process.
Application boundary
Socket-weld connection: three checks before fabrication
“Socket weld” identifies the catalog connection form. It does not define the valve’s rating, material, socket dimensions or welding procedure. Keep the valve specification, piping specification and installation documents aligned, but do not treat them as interchangeable.
Valve standard and piping standard
Confirm the governing valve design / rating standard and edition separately from the project piping code and end-connection requirements. A standard written for socket-weld forged fittings does not, by itself, establish the valve’s design compliance or pressure–temperature rating.
Pipe fit-up and dimensions
Match the controlled valve end drawing to the pipe size, outside diameter, wall / schedule and piping class. Confirm socket dimensions, fit-up allowance and tolerances with the supplier and project piping specification; do not derive them from the product image or a generic fitting table.
Welding and inspection responsibility
Before fabrication, agree who supplies the approved welding procedure, welder qualification records, filler requirements, any required heat treatment, weld examination and test records. The project code, owner specification and valve IOM govern the actual method; no universal weld gap, sequence or heat input is specified here.
Visual evidence
Supplier catalog image
The image supports product identity and general appearance only. It is not a general-arrangement drawing, socket-end detail or bill of materials, and it cannot confirm dimensions, material grade, pressure rating, flow capacity or certification.
Related product routes
Review related globe-valve catalog entries
These are separate catalog identities, not prequalified substitutes. Compare each product against its own drawing, datasheet, rating basis and end connection; specifications do not transfer between pages.
Nickel-Based Alloy Pressure Self-Sealing Globe Valve
A separate catalog entry. Review its own construction, material grade and pressure–temperature basis; the product title alone does not establish a specific alloy or rating.
Y-Type Globe Valve
A separate body-pattern entry. Compare its own drawing, flow data and end connection with the required piping layout; the title does not confirm a socket-weld end.
Forged Steel Power Plant Globe Valve
A separate power-generation catalog entry. Confirm its intended duty, operating envelope, construction and end connection from its own documents before considering it as an alternative.
Buyer questions
Socket Weld Globe Valve FAQ
These answers separate what the catalog identifies from the engineering information needed to select, connect and inspect the offered valve.
What does the supplier catalog confirm?
It identifies this item as a Socket Weld Globe Valve in the Forged Steel Valve series and documents the valve type and socket-weld connection. It does not establish a size, material grade, pressure–temperature rating, trim, actuation, flow coefficient or applicable design / test standard.
Can this valve be used for continuous throttling?
The catalog entry does not provide flow-capacity or control-performance data. For continuous modulation, submit minimum, normal and maximum flow, inlet and outlet pressures, fluid phase, temperature and relevant fluid properties, then request model-specific sizing with the offered trim’s Cv / Kv and flow characteristic versus travel. For line shutoff or occasional manual adjustment, state the required seat-leakage criterion and operating frequency so the offered design can be checked against that duty.
What must be checked before welding the socket-weld ends?
Match the controlled valve end drawing to the pipe size, outside diameter, wall / schedule and piping class. Confirm the applicable piping code and edition, approved welding procedure and welder qualifications where required, filler compatibility, any required preheat or post-weld heat treatment, examination and test boundaries. Use the project documents and valve IOM for exact fit-up and welding instructions; the catalog label does not specify a procedure.
What should an RFQ include?
Send the valve function and required shutoff, medium and phase, design pressure and design temperature, operating pressure range and minimum / normal / maximum operating temperatures, and any applicable pressure surge / transient or vacuum conditions. Include flow cases, allowable pressure drop, any project-specified valve pressure class or rating basis, pipe size and dimensions, body / trim / seat requirements, operation, quantity, and applicable code, drawing, inspection, testing and traceability requirements. If powered actuation is requested, specify actuator type, available utilities, control signal and required fail position / action. Attach a valve schedule or piping isometric if available, and mark unknown values for supplier confirmation.
Technical inquiry
Request a configuration review for Socket Weld Globe Valve
Send the service case, piping specification and available drawings. Mark unknown values rather than assuming them. Request written confirmation of the offered valve configuration, socket-weld interface, required documents and commercial scope before order approval.
- Valve function, operating frequency, minimum / normal / maximum flow and required shutoff
- Medium / phase; design pressure and temperature; operating pressure / temperature range; surge / vacuum cases if applicable; pressure-drop limits and project-specified rating basis if defined
- Pipe size, outside diameter, wall / schedule, line class, flow direction and end drawing
- Body / bonnet, trim / seat, packing, operation and installation; if powered actuation is requested: actuator type, available utilities, control signal and required fail position / action
- Applicable code / edition, welding documents, inspection, testing, traceability, quantity and destination