The supplier catalog identifies this item as Forged Steel Flanged Check Valve in the Forged Steel Valve series. It confirms the check-valve type, the “forged steel” material descriptor and a flanged connection. It does not state the internal design, material grade, size, pressure rating or governing standard. Use the catalog name as the RFQ reference and confirm the offered configuration against the service data and approved drawing.

Product identity

Product identity and source

This page covers one catalog entry, not a complete valve specification. Use the parent Check Valves category to compare operating concepts; use this page to review the exact flanged entry against the project duty and connection.

Product family

Check Valve — the product function identified by the catalog title.

Catalog series

Forged Steel Valve — the series heading printed on the supplier catalog spread.

Evidence source

Supplier catalog, PDF page 112 (printed pages 213–214); the product label and mapped illustration were checked against the archived catalog image evidence.

Catalog evidence

Catalog-documented product data

The catalog label confirms three product descriptors and the source-series context. It does not provide orderable dimensions or performance limits; those must be confirmed for the exact configuration offered.

FieldCatalog-documented valueEvidence status
Valve typeCheck ValveVERIFIED — PDF catalog label
Material descriptorForged steelVERIFIED — PDF catalog label
ConnectionFlangedVERIFIED — PDF catalog label
Catalog source seriesForged Steel ValveVERIFIED — PDF catalog section
Catalog source pagePDF page 112VERIFIED — recovered PDF mapping

Important: Treat the catalog as an identity reference, not an order specification. Do not release line sizing, flange fit or installation from the illustration; use the approved datasheet and dimensioned drawing for the offered configuration.

Evidence boundary

What is confirmed—and what is not

The PDF establishes the product label and mapped image. It does not identify the internal check mechanism or the operating, pressure-boundary and dimensional data needed for procurement.

Confirmed by the catalog

Confirm for the offered configuration

Engineering review

Specify the check valve against the actual duty

A check valve must suit the full operating range and piping arrangement, not only the nominal line size. The supplier needs the flow cases, pressure conditions, fluid properties and pump-trip scenario to assess pressure loss, reverse-flow duty and installation fit.

Flow range and allowable pressure drop

Provide minimum, normal and maximum flow rates with units. State the maximum pressure drop the system can accept across the valve. Ask for documented or calculated pressure loss at each stated duty point for the offered configuration. If the minimum-flow case cannot be checked, do not approve the size from line diameter alone.

Inlet and outlet pressure cases

Give upstream (P1) and downstream (P2) pressures for the minimum, normal and maximum flow cases, together with design pressure and minimum / maximum operating temperature. This establishes the available differential and pressure envelope; “forged steel” and “flanged” are not pressure ratings. Request the configuration-specific pressure–temperature basis.

Medium and material basis

Identify fluid composition and phase, concentration, temperature, viscosity, gas content, solids and corrosive or erosive constituents. Prepare the process datasheet and relevant fluid specification for follow-up. The catalog’s forged-steel descriptor does not identify the body grade, trim, seat or wetted-parts schedule; confirm these against the actual service.

Pump shutdown and reverse flow

Describe normal shutdown, emergency trip and any parallel-pump changeover. Provide pump curve / coast-down data, downstream pressure, line elevation profile and any transient or surge study available. Ask the supplier to review reverse-flow buildup and the offered valve’s closing behavior against the system transient. This catalog entry does not establish a spring arrangement, non-slam design or surge-protection performance.

Flanged connection and installation position

Provide line size, piping class, required flange standard and pressure class / PN, facing, drilling, bore, face-to-face and mating-flange drawing. Mark valve location, flow arrow, horizontal / vertical orientation, elevation, nearby pump and fittings, and available access on a piping isometric or general arrangement drawing. Confirm permitted mounting position and dimensions from the offered drawing and installation, operation and maintenance (IOM) instructions before layout approval.

Document package

Documents to prepare for configuration review

A catalog image is not a dimensioned drawing, and a public product label is not a project datasheet. Send the documents that let the proposed valve be checked against process conditions and the actual pipework.

Process and hydraulic data

Prepare the process datasheet and line list with medium composition, operating / design pressure and temperature, and minimum / normal / maximum flow for follow-up. For pump service, include the pump curve, trip / coast-down information and any transient or surge analysis available.

Piping and connection drawings

Prepare the piping and instrumentation diagram (P&ID) and piping isometric or general arrangement drawing showing valve location, flow direction, elevation, installation orientation, adjacent equipment / fittings, line class and mating flange for follow-up. Mark the available envelope and maintenance access.

Supplier documents to request

Request the datasheet and dimensioned drawing for the offered configuration, plus applicable installation, operation and maintenance (IOM) instructions, material certificates, inspection and test records, marking and traceability details. Confirm document availability, revision, test scope and witness points for this order; none is implied by the catalog entry.

Buyer questions

Forged Steel Flanged Check Valve FAQ

These answers distinguish the catalog identity from the operating and piping information needed to review an order-specific configuration.

What does the catalog confirm for this valve?

The supplier catalog identifies the Forged Steel Flanged Check Valve as a Check Valve with the material descriptor “Forged steel” and a flanged connection in the Forged Steel Valve series. The image confirms catalog appearance only; it does not establish internal construction, material grade, dimensions, pressure rating, standards or certification.

What operating data is needed for selection?

Provide minimum, normal and maximum flow rates, fluid properties, inlet and outlet pressures for each case, design pressure and temperature, and the maximum allowable pressure drop across the valve. Ask the supplier to document pressure loss and operating suitability for the offered configuration; nominal pipe size alone is not a sizing basis.

What should be supplied for pump shutdown or reverse-flow duty?

Describe pump start / stop and trip conditions, coast-down data where available, downstream pressure, line profile and any estimated reverse-flow or transient case. Request a review of the offered valve’s closing behavior against the system transient; this catalog entry does not establish a non-slam design or surge-protection performance.

Which drawings and service documents should accompany the RFQ?

Prepare the process datasheet and fluid information, piping and instrumentation diagram (P&ID), piping isometric or general arrangement showing valve location, flow direction and installation orientation, plus the mating-flange or line-class drawing for follow-up. Summarize the relevant operating and connection conditions in the inquiry, and ask VALMORA how to share the drawings and datasheets if needed. Request the offered datasheet, dimensional drawing and applicable installation, material, inspection and test records, with document availability and revision confirmed for the specific order.

Technical inquiry

Request a configuration review for Forged Steel Flanged Check Valve

Reference this catalog identity and summarize the operating conditions and piping requirements in the Technical requirements field. If drawings or datasheets are needed, ask VALMORA to confirm how to share them after contact. The review can then address the offered configuration, pressure loss, reverse-flow case, connection fit and requested documentation; unresolved product data remains subject to confirmation.

Fields marked * are required.