Skip to content

PDF-documented product

DN5,000 Electric Vacuum Butterfly Valve

Blue DN5,000 electric vacuum butterfly valve shown on supports in the catalog

The recovered English catalog identifies this item as DN5,000 Electric Vacuum Butterfly Valve on PDF page 97. It confirms a butterfly-valve product identity with electric actuation and a vacuum service descriptor. It does not publish a vacuum pressure range, allowable differential pressure, leakage rate, connection dimensions, material grades or actuator rating. Those values must be established for the proposed assembly before specification or purchase.

Product identity

What this catalog record confirms

This page covers one catalog-listed product identity. Use the parent Butterfly Valves category to compare the wider range; do not transfer dimensions, ratings or material details from another catalog entry.

Product family

Butterfly Valve. This is the parent product family named in the recovered catalog.

Catalog series

Butterfly Valve Series. The source PDF places this product under that series heading.

Evidence source

Recovered English product catalog, PDF page 97 (printed spread pages 183–184); matching product photograph identified on that spread.

Catalog evidence

What the catalog actually documents

The table below records the product identity as printed. “Vacuum” is a catalog service descriptor, not a published performance rating. DN5,000 is retained as the catalog designation; it is not a verified bore or flange dimension.

FieldCatalog-documented valueEvidence status
Product nameDN5,000 Electric Vacuum Butterfly ValveVERIFIED — exact PDF catalog label
Valve typeButterfly ValveVERIFIED — PDF catalog label
ActuationElectricVERIFIED — product label only; no actuator specification
Service descriptorVacuumVERIFIED — product-name descriptor only; no vacuum rating
Catalog designationDN5,000VERIFIED — catalog label; actual dimensions require a drawing
Catalog seriesButterfly Valve SeriesVERIFIED — PDF section heading
Source locationPDF page 97 (printed spread 183–184)VERIFIED — recovered catalog mapping

For dimensional selection: use the proposed general-arrangement (GA) drawing and the project’s mating-pipe data. The catalog photograph and DN5,000 label are not enough to establish the flow bore, flange standard or specified rating, drilling, face-to-face length or disc clearance.

Evidence boundary

Confirmed identity and open engineering data

The catalog confirms the product name, butterfly-valve family, electric actuation, vacuum descriptor and DN5,000 designation. It does not establish the valve construction, vacuum operating range, allowable differential pressure, leakage performance, actual pipeline interface, material schedule or matched actuator package. The catalog photograph supports product identity and appearance only; it does not establish dimensions, material grade, pressure rating, certification or the final supplied configuration.

Confirmed by the catalog

Confirm before quotation

Engineering review

What to specify for vacuum service and electric operation

A vacuum-valve inquiry needs more than the word “vacuum.” Define the pressure on each side, the required shutoff leakage, the physical pipeline interface and the electric control duty. The proposed valve, seat and actuator must be reviewed as one assembly.

Valve duty

State whether the valve is for isolation, throttling, bypass or another defined function. Give normal and upset flow conditions, required open/close frequency, full-stroke time and the required closed-position leakage criterion. Do not assume modulating service from the butterfly-valve type.

Vacuum pressure and differential

Provide minimum, normal and maximum absolute pressure, with units, on each side of the valve. Also state the maximum differential pressure across the disc, its direction during opening and closing, and any pumpdown, venting, start-up or upset transient, including positive pressure if applicable. A vacuum level and the differential load across the disc are related but are not interchangeable inputs.

Seat sealing and materials

Specify the allowable seat leakage and external body/shaft leakage separately, including units, test gas, pressure direction, test method and acceptance conditions. Identify the process gas or vapor, condensables, particles, corrosive constituents and temperature range so the supplier can propose and document the body, disc, shaft, seat and seal materials. The catalog name does not establish a leakage rate or material grade.

Electric actuator and controls

State the site power supply (voltage, phase and frequency), on/off or modulating duty, required travel time, cycles or starts, command and position-feedback signals, local controls and manual operation needs. Define the required response to power loss and signal loss separately. Request the opening, running and closing torque basis at the stated worst-case differential pressure and confirm that actuator output does not exceed the valve’s allowable shaft torque.

Dimensions, support and documents

Treat DN5,000 as the catalog designation until the supplier confirms the actual flow bore and mating dimensions. Request the GA drawing showing the flange/end standard and any specified flange rating, drilling, face-to-face length, sealing face, gasket arrangement, disc swept envelope, actuator clearance, assembly mass, center of gravity and lifting points. Agree the applicable design and test standards, vacuum/leak test conditions, material records, inspection or witness points, marking and final document list.

Service and installation

Match the valve to the actual vacuum system

The product label does not identify the process gas, thermal environment or installation loads. These details affect material compatibility, sealing requirements and whether the proposed large assembly can be installed and maintained.

Process gas and contamination

Identify the gas or vapor composition, condensable components, dust or particles, moisture, corrosive or erosive constituents and cleaning method. If contamination or outgassing limits matter, state the project requirement and ask the supplier to identify the materials and surface condition of gas-wetted parts.

Temperature and operating environment

Provide minimum, normal and maximum process temperatures, ambient conditions and any thermal cycling or, if applicable, bake-out requirement. State whether the valve is exposed to outdoor weather, corrosive atmosphere or hazardous-area conditions so the offered seals, actuator enclosure and electrical package can be checked.

Installation, support and access

Confirm mounting orientation, pipe loads, support arrangement, available space, access for the full disc and actuator travel, cable routing and maintenance clearance. For a valve of this catalog designation, request assembly mass, center of gravity and approved lifting points; do not derive handling or support loads from the photograph.

Buyer questions

DN5,000 Electric Vacuum Butterfly Valve FAQ

These answers separate the catalog identity from the engineering data needed to approve a vacuum-valve assembly.

What does the catalog confirm for this valve?

The recovered English catalog identifies a DN5,000 Electric Vacuum Butterfly Valve in the Butterfly Valve Series. It labels the product as a butterfly valve with electric actuation and a vacuum service descriptor. It does not state a pressure range, leakage rate, actual connection dimensions, materials or actuator specification.

Does DN5,000 mean a measured 5,000 mm bore or flange size?

No. This page preserves DN5,000 as the catalog designation. A DN number is a nominal-size reference, not a measured bore or flange dimension. Confirm the actual flow bore, mating flange standard and any specified rating, drilling, face-to-face dimensions and disc clearance on the approved general-arrangement drawing.

What leakage information is needed for vacuum service?

Specify seat (internal) leakage and external body/shaft leakage separately, with acceptance values and units, test gas, pressure direction, test method and conditions. Also provide the minimum, normal and maximum absolute pressure and the maximum differential pressure across the disc. The word “vacuum” in the catalog name is not a leak-rate or vacuum-range rating.

What should the electric actuator quotation include?

State on/off or modulating duty, cycle frequency, full-stroke time, power supply, command and feedback signals, local/manual requirements, and the required response to power or signal loss. Request the actuator sizing basis at the worst specified differential pressure and verify the valve’s allowable shaft torque.

Technical inquiry

Request a DN5,000 vacuum butterfly valve configuration review

Reference the catalog identity and provide the vacuum duty, sealing criterion, actual pipeline interface and electric control requirements. The review should establish which data are confirmed, which require supplier documentation and what must appear on the proposed GA drawing. Use the form to describe the requirements you have; confirm the file-submission method separately if drawings or specifications need to be reviewed.

Fields marked * are required.