Skip to content

Pipeline valve with pneumatic-hydraulic actuation

Pneumatic-Hydraulic Linkage Natural Gas Pipeline Ball Valve

Pneumatic-hydraulic linkage ball valve with a tall actuator assembly

This catalog entry identifies a ball valve with pneumatic-hydraulic linkage in a natural-gas pipeline product context. The source catalog places it in the Fully Welded Valve series. For a project quotation, the valve and its actuator must be reviewed as one assembly: the valve torque, actuator output across the stroke, available motive energy, any required stored-energy arrangement and installation envelope all need to match the specified duty.

Product identity

What the catalog identifies

The product name identifies the valve family, actuation wording and service context. The catalog section is titled Fully Welded Valve; this is the source-series label, not a substitute for the construction drawing or a complete design specification.

Valve family

Ball Valve — the product family shown in the catalog and the relevant parent category for selection.

Source series

Fully Welded Valve — the series heading under which this catalog entry appears. Confirm the exact body construction and end details on the offered drawing.

Catalog record

English product catalog, PDF pages 87–88 (printed catalog pages 163–166). The catalog images establish product identity and visual context only; they are not dimensioned general-arrangement drawings.

Catalog evidence

Catalog-confirmed product identity

The entries below reproduce the product identity and labels shown in the source catalog. They are not a technical datasheet. No pressure rating, size range, material grade, leakage class, gas compatibility, actuator supply range or certification is established by these labels.

Catalog fieldCatalog wordingWhat it establishes
Valve typeBall ValveProduct family only
ActuationPneumatic-hydraulic linkageActuation wording only; not a circuit or fail-action specification
Service wordingNatural gasCatalog service label only; not verified fluid compatibility
Source seriesFully Welded ValveCatalog section heading; confirm construction on drawing
Catalog locationPDF pages 87–88 (printed catalog pages 163–166)Source reference, not a dimensional drawing

For procurement: request the model-specific valve datasheet, actuator data sheet and approved general-arrangement drawing. Use those documents—not the catalog photographs—to verify dimensions, ratings, interfaces and the supplied configuration.

Evidence boundary

What is known — and what the quotation must establish

The catalog confirms a ball-valve product entry and names pneumatic-hydraulic linkage. It does not provide enough information to approve a valve/actuator assembly for a particular pipeline duty. The decisive gap is the absence of matched valve torque data, actuator output data, motive-energy details and a dimensioned assembly drawing.

Confirmed by the catalog

Confirm before quotation

Engineering review

How to verify the valve and pneumatic-hydraulic actuator as one assembly

Do not select the actuator from valve size or a single nominal torque figure. First establish the valve torque under the project operating cases; then check that the actuator can deliver the required output throughout the complete stroke at the minimum available motive pressure, without exceeding the allowable torque of the stem, coupling or mounting components.

Valve torque basis

Request the valve manufacturer’s torque schedule for the specified size, seat materials, differential pressure, temperature and operating direction. It should distinguish breakaway, running and end-of-travel torque in both opening and closing directions. Include cycling frequency and any service-related correction factors. A generic torque value or a value from another valve model is not a sizing basis.

Actuator output and margin

Compare the actuator’s opening and closing output curves with the corresponding valve torque requirements over the full stroke. Obtain output values at the project’s minimum and maximum supply conditions. Check both normal operation and any stored-energy / failure stroke, and verify that peak actuator output remains within the allowable stem, coupling and mounting-interface limits.

Dimensioned assembly and mounting

Ask for a dimensioned general-arrangement drawing showing the valve, actuator and all accessories included in the offered package, such as any gas/air receiver or bottle, hydraulic reservoir or accumulator, control panel, tubing and mounting hardware. Confirm the overall envelope, actuator orientation, stem and mounting interfaces, end-to-end dimensions, mass, lifting points, support loads, maintenance clearances and access to any manual override, if fitted. The catalog photographs are not dimensional references.

Confirm the gas/air supply, hydraulic circuit and any stored-energy arrangement

Identify the actual motive gas or air, its quality and minimum/maximum pressure at the actuator—not only at the upstream supply. Request the offered hydraulic-circuit schematic and the hydraulic fluid, operating pressure, stroke volume, port sizes and tubing details. If the engineered package includes a gas/air receiver or bottle, hydraulic reservoir or accumulator, confirm its capacity, charging and isolation interfaces, and pressure indication. Specify alarms and interlocks where required by the project control philosophy. Do not assume pipeline gas is the actuator supply medium.

Loss-of-energy action and test records

Define the required response separately for loss of motive gas or air and loss of hydraulic pressure, and for loss of electrical power where electrical controls are included. Confirm whether the offered assembly is designed to fail open, fail closed or remain in its last position. If stored energy is part of the offered configuration, define the required number of complete strokes and the conditions under which they must be available. Request the cause-and-effect / operating sequence, functional test procedure and records, approved drawings, material documentation and the project-specified pressure, leakage and qualification reports.

Application boundary

What to settle before the actuator package is quoted

The correct package depends on the pipeline duty and the site utilities. The product name alone does not establish suitability for every natural-gas composition or operating envelope. Use the following inputs to turn the catalog identity into a reviewable technical specification.

Pipeline duty and process conditions

Provide gas composition and contaminants, normal and design pressure, maximum differential pressure across the closed valve, minimum/maximum temperature, flow direction, required isolation or control duty, operating frequency and required operating time. These conditions govern material compatibility, seat selection and the valve torque cases to be evaluated.

Site utilities and control philosophy

State whether the actuator is to use instrument air, nitrogen, pipeline gas or another specified supply, and provide the available minimum and maximum pressure at the package inlet. Identify hydraulic-fluid requirements, electrical supply, control signals, remote/local operation, position feedback, alarms and the required response to each utility failure.

Installation and maintenance envelope

Confirm pipeline orientation, actuator orientation, available headroom and lateral clearance, foundation or support details, ambient conditions, hazardous-area requirements, access for maintenance and for manual operation, if fitted, and the route for control tubing and cables. Review the complete assembly drawing against the site layout before approving the order.

Buyer questions

Pneumatic-hydraulic linkage ball valve: buyer questions

Answers below distinguish the catalog label from the engineering information needed to approve an actuated valve package.

What does the catalog confirm about this valve?

It identifies a Ball Valve with pneumatic-hydraulic linkage in a natural-gas pipeline product context, under the Fully Welded Valve catalog series. The catalog pages and matched images establish product identity and appearance, not a complete technical specification.

Does the catalog provide actuator dimensions or operating torque?

No dimensioned assembly drawing, valve torque schedule or actuator output curve is established by the supplied catalog pages. Request a model-specific general-arrangement drawing and torque data for the project’s pressure, temperature and supply conditions.

What should be checked for the gas-hydraulic actuator package?

Check the valve torque through the full stroke against actuator output at minimum and maximum supply pressure. Also verify the gas or air supply medium, hydraulic fluid and volume, any receiver, vessel or accumulator included in the offered package, connection sizes, control accessories, mounting interface and installation envelope.

What happens if the motive gas, hydraulic pressure or power is lost?

The required response must be specified for each loss-of-energy case. The assembly may be designed for fail-open, fail-closed or fail-last behavior depending on its actual circuit and stored-energy arrangement. The catalog label does not establish which response this product provides; request the operating schematic, cause-and-effect description and functional test evidence.

Technical inquiry

Request a technical review and quotation

Reference this catalog product and provide the pipeline duty and site utility data. VALMORA can then identify the information needed to review the valve, actuator, any stored-energy arrangement included in the offer, and documentation as one assembly. This inquiry form accepts text details; it does not provide a file-upload field.

Fields marked * are required.