Skip to content

Catalog-identified product · manual lever operation

PTFE-Lined Lever Wafer Butterfly Valve

Catalog image of PTFE-lined lever-operated wafer butterfly valve, blue body and white-lined bore

The source catalog names the pictured item PTFE Lined Lever Wafer Butterfly Valve in its Anti-Corrosion Valve Series (physical PDF page 110). It shows a lever-operated, wafer-pattern design. The label does not state an orderable size, rated pressure, operating temperature or complete wetted-material schedule.

Product identity

What the catalog actually identifies

This record concerns the lever-operated PTFE-lined wafer product shown here, not every wafer butterfly valve. For other actuation types, unlined designs and broader selection, use the wafer butterfly valve series or the parent Butterfly Valves category.

PTFE lining

PTFE-lined is part of the printed catalog name. The exact liner construction, coverage, thickness and remaining wetted materials require an order-specific specification.

Lever operation

The catalog label and product photo show a manual lever. Do not assume the same actuation is suitable for a high operating differential pressure or frequent/remote cycling.

Wafer body pattern

The image shows a wafer-style body intended to be located between mating flanges. Bolt pattern, face-to-face dimension, flange sealing arrangement and disc clearance are not provided by this label.

Catalog evidence

Documented identity and missing specification data

The original catalog page identifies the pictured configuration; it is not a certified dimensional drawing or a pressure-temperature datasheet. Treat the fields below as identity evidence, not complete procurement specifications.

AttributeEvidence / statusProcurement implication
Catalog product namePTFE Lined Lever Wafer Butterfly ValvePrinted label, PDF physical page 110
Body connection formWafer butterfly valveVerify actual mating flanges, disc travel and lay length
Lining descriptorPTFE linedConfirm complete wetted materials and PTFE liner construction
Operator depictedHand leverConfirm required operating torque and intended manual duty
Source categoryAnti-Corrosion Valve SeriesA catalog grouping, not an application or chemical-compatibility approval
Size / pressure / temperatureNot stated for this pictured entryRequest a model-specific datasheet and allowable service envelope
Dimensions / testing / complianceNot stated for this pictured entryRequest drawings, test basis and project-specific documents

Do not transfer series-wide limits to this item. No size range, pressure rating, temperature limit, flange standard, chemical compatibility or shutoff class is established by the pictured catalog entry.

Evidence boundary

What is known—and what must be selected

The catalog establishes the pictured body style, lining descriptor and operator type. It does not prove which particular service can be accepted. Selection must start with the fluid and duty, then the specific offered design.

Supported by the pictured label

Request for the offered model

Engineering review

When is this lever-operated PTFE-lined wafer design appropriate?

Use this catalog identity as a candidate when the project needs a manually operated wafer butterfly valve and a PTFE-lined construction is under consideration. The decision changes if the medium is incompatible with the proposed wetted parts, the lever torque is impractical or the mating flanges restrict disc movement. These are selection gates—not confirmed performance claims for this item.

Manual lever or different actuation?

For accessible, occasional manual operation, request the lever version with the required maximum differential-pressure torque. If the point is remote, operated frequently, or the required torque exceeds reasonable manual operation, compare a worm-gear wafer variant or a separately specified automated design. Do not assume interchangeability or identical pressure limits.

PTFE lining and the process medium

PTFE lining can be considered where chemical resistance is an important selection factor, but the PTFE name alone does not qualify the valve for a fluid. Submit the full composition and concentration, temperature extremes, solids, cleaning agents and any vacuum or permeation conditions. Review liner construction and all wetted components against that service.

Will it fit the mating flanges?

A wafer body is clamped between pipe flanges; it does not guarantee compatibility with every ASME, EN or JIS flange. Compare the offered valve drawing with actual flange drilling, face inside diameter, raised/flat face geometry, face-to-face space and disc swing clearance. The required gasket arrangement must come from the offered liner design and installation manual—not a generic rule for every butterfly valve.

Isolation duty or throttling duty?

Define the normal and maximum differential pressure, direction of pressure, leakage requirement and operating frequency. If continuous throttling is expected, obtain the proposed valve’s flow/torque suitability and consider vibration, cavitation or erosion risk under the real service; this photograph does not establish a control characteristic or shutoff class.

Approve a technical offer, not a picture

Before ordering, compare the offered datasheet, dimensional drawing, materials/liner specification, operating limits and document/test scope with the RFQ. Ask the supplier to distinguish the pictured lever configuration from any substitutions or optional operators in writing.

Application boundary

Three conditions that can rule out a quick catalog match

The same PTFE-lined wafer description can lead to different procurement decisions when the fluid, operating duty or pipe interface changes. The checks below belong to the selected design—not to a blanket industry application claim.

Unspecified chemical or mixed media

An anti-corrosion catalog heading is not a chemical-resistance guarantee. Where the medium is a mixed chemical, high-solids stream or subject to temperature cycling, hold the selection until the liner and every wetted material have been assessed against the actual fluid and operating envelope.

High-cycle, remote or inaccessible operation

The pictured handle is not an automatic or remotely controlled operator. For remote isolation, repeated cycling or defined fail action, specify the control philosophy and compare the appropriate operated variant. Sizing an actuator requires the chosen valve’s torque data and differential-pressure case.

Unverified flange fit or sealing

A matching nominal size is insufficient. Check flange bore against disc travel, flange faces against the seat/liner interface, and the available installation gap against face-to-face dimensions. Do not specify extra gaskets, end-of-line service or a permitted installation orientation without the proposed model’s instructions and design basis.

Buyer questions

Questions about this catalog-listed valve

These distinctions are important before using the photo as the basis for a purchase specification.

Is this an unlined or generic wafer butterfly valve?

No. The original catalog labels the pictured product PTFE Lined Lever Wafer Butterfly Valve. The parent wafer series includes different constructions and operators; this page describes only the pictured catalog identity.

Does PTFE lining prove chemical compatibility?

No. The lining description does not establish the complete wetted-material list, liner construction or pressure-temperature limits. Send the exact medium, concentration, operating conditions and cleaning requirements for a model-specific compatibility review.

Can the image confirm flange or gasket compatibility?

No. Require the offered valve drawing and installation instructions to check bolt circle, face-to-face, flange bore, disc swing and sealing arrangement. Different seat/liner designs may have different gasket requirements.

What makes the RFQ technically actionable?

Identify this PTFE-lined lever wafer catalog entry and provide line size, mating flange dimensions/standard, medium, pressure-temperature cases, isolation or throttling duty, required shutoff, operating frequency and document/inspection requirements. State quantity and ask for the selected configuration’s datasheet and drawing.

Technical inquiry

Request a quotation for the PTFE-lined lever wafer valve

Reference the PTFE Lined Lever Wafer Butterfly Valve (catalog page 110). Include the project conditions below; unknowns can be identified as such. Ask VALMORA to return the exact offered design, exclusions, compatible flange details and required documentation before price comparison.

Fields marked * are required.