Skip to content

Catalog-listed product

Parallel Safety Backflow Valve

Parallel Safety Backflow Valve catalog image

The English supplier catalog identifies this item as Parallel Safety Backflow Valve in the Safety Valve series on PDF page 105. VALMORA places this page in its Safety/Relief Valve website category. The catalog series and the site category have different sources; neither establishes the valve’s exact operating function, pressure response, connection standard or approval status.

Product identity

What this catalog record owns

This page represents one documented catalog identity. It does not replace the parent product category or claim an unverified model, rating, system duty or project history.

VALMORA product category

Safety/Relief Valve. This is VALMORA’s parent product category and commercial navigation route, not a supplier catalog series.

Catalog series

Safety Valve. This is the source-series context printed in the recovered product catalog.

Evidence source

Recovered English supplier catalog, PDF page 105.

Catalog evidence

Catalog identity and site classification

The supplier catalog documents the product name, the Safety Valve source series and PDF page 105. A small example model/DN marking appears above the product illustration, but its exact characters have not been verified from the available low-resolution catalog page. This printed illustration label does not establish an orderable model or the nominal-size range currently available from the supplier. Safety/Relief Valve is VALMORA’s site category, verified from this page’s URL and frozen WordPress metadata, not a supplier catalog field. The actual offered model, nominal size, pressure designation, material grade, connection standard, action pressure, rated flow, internal construction and certification require supplier confirmation against the applicable datasheet and drawings.

FieldRecorded valueEvidence source
Catalog product nameParallel Safety Backflow ValveVERIFIED — PDF product label
Catalog source seriesSafety ValveVERIFIED — PDF catalog section
Catalog source pagePDF page 105VERIFIED — recovered PDF mapping
Catalog illustration labelExample model/DN marking printed above the image; exact characters not transcribedVERIFIED — example marking appears on catalog page 105; NOT VERIFIED — precise characters, orderable model or available nominal-size range
VALMORA product categorySafety/Relief ValveVERIFIED — VALMORA page route and frozen WordPress lg_valve_type; not supplier catalog data

Important: Model, nominal size, pressure designation, action pressure, flow capacity, materials, end connections, standards and approvals remain unconfirmed. Resolve them against the datasheet and approved drawing for the exact offered configuration before quotation.

Evidence boundary

Known facts and open configuration fields

The supplier catalog confirms the product name and its Safety Valve source series. The cropped product image is an identity reference only. Neither the label nor the image establishes the internal design, normal flow path, pressure response, operating envelope, dimensions, material grades, rated capacity or installation suitability.

Confirmed by the catalog

Confirm before quotation

Engineering review

How to specify the Parallel Safety Backflow Valve

The catalog label does not show whether this valve is intended to provide pressure-responsive liquid return, prevent reverse flow as a check valve, or serve within a separate backflow-prevention assembly. Start with the required function and a piping sketch. The offered configuration must then be checked against the actual system duty and mating interfaces.

Required function and system position

Identify the protected equipment and the exact line where the valve is proposed. Show the pump, tank or equipment, normal flow direction, intended return or reverse-flow path, existing check valve, shutoff valves and any backflow-prevention assembly. Mark whether the proposed valve sits upstream or downstream of those devices and whether it is in a branch, series or parallel path; do not infer the piping arrangement from the product name. Include orientation, available space, piping loads, access, maintenance clearance, relevant ambient exposure conditions and the intended maintenance method. State whether the required action is pressure-triggered return, non-return protection or another defined function. If the duty is pressure relief, provide the relief case, required capacity basis, target set pressure and allowable accumulation/overpressure.

Operating envelope

Provide normal, minimum and maximum operating pressure, design pressure, operating/design temperature and expected flow. Include pump discharge pressure and return-line pressure where applicable, plus pressure surges or vacuum cases if relevant. For a pressure-responsive return or relief duty, state the required opening/action condition and allowable back pressure; for a check/backflow duty, describe the differential-pressure and reverse-flow conditions. No action pressure or rated capacity is verified in this catalog record.

Materials and connection

Provide fluid composition and phase, concentration, solids or contaminants, corrosion/erosion risks and cleaning requirements. Confirm line size, end type, flange standard, pressure designation, facing, bolt pattern and mating dimensions from the project piping documents. The supplier must confirm body, trim, seat/seal and wetted-part materials for the stated service.

Actuation and control, if applicable

State whether external actuation or a control signal is required. If so, identify the actuator type, available utilities, control signal and required fail position. If the valve is expected to operate automatically from line pressure or flow, describe the required response and ask the supplier to confirm the actual construction.

Inspection and documents

List the required datasheet, dimensional drawing, installation instructions, material records, pressure/leakage tests, inspection, marking and any third-party witness documents. Confirm the availability and scope of evidence for the exact offered configuration. A requested certificate does not establish system-level or installation approval.

Buyer questions

Parallel Safety Backflow Valve FAQ

These answers preserve the line between documented catalog evidence and project-specific selection.

What does the PDF catalog confirm for this product?

It confirms the product name Parallel Safety Backflow Valve, its Safety Valve source series, and the catalog source page (PDF page 105). Separately, Safety/Relief Valve is VALMORA’s website category, not a verified supplier catalog-family label. The catalog does not confirm a complete model specification or system duty.

Which data still requires confirmation?

The exact model, construction, size, pressure designation, action pressure, materials, connections, operating limits, standards, testing, dimensions, price and lead time require confirmation for the offered configuration. The catalog also does not establish that this product is a standard check valve, a listed backflow-prevention assembly or a certified system.

Can the catalog image be used as a final dimensional reference?

No. The catalog image supports product identity and general appearance only. Use the confirmed datasheet, dimensional drawing and approved order drawing for selection, fabrication and installation.

What should be included in the RFQ?

Provide the required valve function and service medium; a piping sketch showing the pump, tank or protected equipment, normal and return/reverse-flow directions, and the position of existing check or backflow-prevention devices; operating pressures and temperatures; line size and mating connections; materials; ambient exposure and intended maintenance method where relevant; actuation if applicable; quantity; and required drawings, tests, inspections and approval documents.

Technical inquiry

Request a configuration review for Parallel Safety Backflow Valve

Reference this catalog identity and provide the intended system function, line position, operating conditions and mating interfaces. VALMORA can then review the proposed configuration, document scope and commercial terms without turning unverified catalog details into specifications. System or regulatory approval must be evidenced separately for the exact project and offered configuration.

Fields marked * are required.