Ir para o conteúdo

Produto documentado em PDF

Válvula de retenção para mina de carvão com abertura e fechamento lentos

Coal Mine Specific Slow-Opening and Slow-Closing Check Valve catalog image with blue vertical cylinder assembly

The catalog identifies this item as the Válvula de retenção para mina de carvão com abertura e fechamento lentos. Its title and matched illustration establish catalog identity only; they do not specify stroke times, the control mechanism, mine-use approval, an explosion-protection rating or transient performance. Confirm the offered design against its approved drawing and actual service data before quotation.

Identidade do produto

Product identity and catalog source

This page records one documented product identity under the Check Valve family. Use it to identify the catalog item, not to infer a complete model, pressure rating, operating sequence or project approval.

Família de produtos

Check Valve. The parent Check Valves category handles family-level selection.

Série de catálogo

Quick Closing Check Valve. This is the catalog section heading; it does not establish the opening and closing sequence or timing of this specific product.

Fonte de evidência

Recovered English supplier catalog, PDF page 107; the product illustration has been matched to the Coal Mine Specific Slow-Opening and Slow-Closing Check Valve label.

Evidência do catálogo

Dados de produto documentados no catálogo

Only catalog wording is shown as verified. “Coal mine” is the product’s catalog application label, not a confirmed process medium. The catalog does not establish dimensions, materials, pressure or temperature limits, operating times, construction details, standards or approvals.

CampoTexto do catálogoStatus da evidência
Tipo de válvulaVálvula de retenção de esferaVERIFICADO — rótulo do catálogo em PDF
Redação de aplicação do catálogoCoal mineVERIFIED — product label only; actual fluid not established
Contexto do setorMineraçãoVERIFIED — catalog wording only
Seção do catálogoQuick Closing Check ValveVERIFIED — PDF section heading; not model timing data
Página de origem no catálogoPDF page 107VERIFICADO — mapeamento de PDF recuperado

Importante: Values not listed above remain unconfirmed. Confirm the exact offered configuration, operating limits, materials, connections and required documents against the supplier’s current datasheet and approved order drawing.

Limite de evidência

Dados confirmados e campos de configuração em aberto

The catalog confirms the product label and matched appearance. It does not establish a complete bill of materials, pressure-temperature envelope, stroke-time specification, mine-use approval or order-ready configuration.

Confirmado pelo catálogo

Confirmar antes da cotação

Análise de engenharia

How to specify the Coal Mine Specific Slow-Opening and Slow-Closing Check Valve

An orderable specification needs more than the catalog title. Use the approved drawing and duty data to confirm how the valve opens and closes, what fluid it handles, and whether the installation matches the offered design.

Opening and closing sequence

Request the sectional or assembly drawing and operating sequence. Confirm what initiates each stroke, the required opening time and closing time, any staged or adjustable travel, the control or actuation method, and the response on loss of power or utility. If available, review a time-versus-travel curve. Do not infer seconds or a mechanism from the catalog name or illustration.

Envelope operacional

State the actual medium and its composition, including solids content or gas fraction, concentration, viscosity and contaminants where applicable. Provide minimum, normal and maximum flow; forward and reverse differential pressure; nominal size and pressure designation/rating basis; design and operating pressure and temperature; and credible start-up, shutdown, pump-trip or vacuum cases. The catalog wording “Coal mine” does not identify the process fluid.

Materiais e conexão

Specify body, trim, seat/seal and all wetted materials against the actual fluid, concentration, temperature and corrosion or erosion exposure. Confirm the end type, face-to-face and mating dimensions, flange or thread standard, and piping-interface constraints from the approved drawing.

Requisito de acionamento

Identify whether the offered arrangement is self-acting or uses an external operating or control device. If external actuation is shown on the drawing, state the available electrical, pneumatic or hydraulic utility, control signal, local/remote requirement and required fail response. Do not assume a particular mechanism is standard.

Inspeção e documentos

List the records and acceptance checks required for this order: approved GA or sectional drawing, datasheet, material records, pressure/leakage test records, functional timing or sequence test if specified, inspection and witness points, nameplate/marking, and any project-specific approval. Confirm which items are available for the offered configuration before order placement.

Limite de aplicação

Relacione a identidade do catálogo ao serviço real

The product name contains a coal-mine reference, but the name alone does not qualify the valve for a mine, hazardous area or particular fluid. Suitability must be established from the actual design, operating conditions and required site approvals.

Redação de aplicação do catálogo

“Coal mine” is the catalog label for this product identity. It does not confirm whether the process medium is water, slurry, gas, air or another fluid. State the actual composition, solids content, concentration, temperature and contaminants for material and trim review.

Mining context and approvals

Mining is the catalog industry context only. No mine-use permit, explosion-protection rating, hazardous-area classification or jurisdiction-specific approval is established by the product name or illustration. Request the exact certificates and scope required by the project.

Limite de instalação

Use the approved drawing and installation instructions to confirm the body flow arrow, permitted orientation, upstream/downstream piping arrangement, mating dimensions, pipe supports and loads, access to any external device, maintenance clearance and ambient conditions. Do not infer mounting direction or clearances from the catalog image.

Perguntas do comprador

Coal Mine Specific Slow-Opening and Slow-Closing Check Valve FAQ

Estas respostas mantêm a distinção entre a evidência documentada no catálogo e a seleção específica do projeto.

O que o catálogo confirma para este produto?

It confirms the product name, Check Valve type, “Coal mine” catalog wording, Mining industry context, the Quick Closing Check Valve catalog section and the matched product illustration. It does not establish the actual process fluid, operating times, construction, ratings or approvals.

Quais dados ainda exigem confirmação?

Confirm the exact construction, opening and closing triggers and times, actual medium and flow range, pressure and temperature limits, materials, connections, permitted orientation, control utilities, applicable standards or approvals, required tests, documents, price and lead time against the offered configuration.

A imagem do catálogo pode ser usada como referência dimensional final?

No. The illustration confirms catalog identity and appearance only. Use the approved general-arrangement or sectional drawing, datasheet and installation instructions for dimensions, fabrication, installation and procurement.

O que deve ser incluído na solicitação de cotação?

Provide the actual fluid and composition, flow direction and range, operating/design pressure and temperature, opening and closing triggers and required times, installation orientation and piping layout, connection and material requirements, actuation/utility details if applicable, quantity, and the required drawings, tests, inspections and project approvals.

Consulta técnica

Request a configuration review for Coal Mine Specific Slow-Opening and Slow-Closing Check Valve

Reference this catalog identity and provide the actual duty and installation data. Request confirmation of the offered construction, operating sequence, operating limits and document scope before treating the item as suitable for a project.

Os campos marcados com * são obrigatórios.