İçeriğe geç

Katalogda tanımlanan ürün

Electric Triple Eccentric Metal-to-Metal Fully Welded Butterfly Valve

Electric triple-eccentric metal-to-metal fully welded butterfly valve with a white electric actuator, catalog view AST-R1-0313.

The Lianggong catalog identifies this item as an electric, triple-eccentric, metal-to-metal, fully welded butterfly valve. It confirms the product-family label, electric actuation and welded wording, but it does not publish an order-ready size, pressure-temperature envelope, line-end preparation, leakage criterion or actuator rating. Use the catalog name to identify the record; use the offered sectional/GA drawing and datasheet to decide whether the valve fits the pipeline and shutoff duty.

Ürün kimliği

Bu katalog kaydının tanımladıkları

This page identifies one catalog entry, not a complete order specification. The catalog wording does not define the full bill of materials, end details, pressure-temperature limits, leakage performance or actuator package. Do not transfer ratings or dimensions from adjacent butterfly-valve records.

Ürün ailesi

Kelebek Vana. Bu, kategori düzeyinde seçim için ana ticari yoldur.

Katalog serisi

Kelebek Vana. Bu, geri kazanılan ürün kataloğunda basılı kaynak seri bağlamıdır.

Kanıt kaynağı

Recovered English Lianggong product catalog, PDF page 97 (printed pages 183–184); matching product-image tokens AST-R1-0312 and AST-R1-0313.

Katalog kanıtı

Katalog belgeli ürün verileri

The table records only what the source catalog names. It does not turn a product title or series-level heading into a model-specific rating, end connection or certification claim.

AlanKatalog ifadesiKaynağın ortaya koyduğu
Vana tipiKelebek VanaExplicit PDF product label
Tasarım / yapıTriple eccentricExplicit product label; detailed offset geometry is not shown
AktüasyonElektrikliExplicit product label; actuator model and electrical data are not shown
Sealing descriptionMetal-to-metalExplicit product title; seat details and leakage acceptance are not shown
Welded wordingFully welded / WeldedExplicit product title and catalog field; exact body and line-end details are not shown
Katalog kaynak serisiKelebek VanaPDF section heading
Katalog kaynak sayfasıPDF page 97 (printed pages 183–184)Recovered catalog mapping

Önemli: the spread also shows a DN 5,000 maximum-production-size heading for the Butterfly Valve series. That is a series-level statement, not a size range established for this individual product. Confirm size, pressure-temperature limits, end details and test acceptance on the offered datasheet and approved drawing.

Kanıt kapsamı

Bilinen bilgiler ve açık konfigürasyon alanları

The catalog establishes the product identity, not an order-ready configuration. Materials, ratings, end details, seat leakage and actuator data remain open until they are tied to the offered drawing and datasheet.

Katalog tarafından doğrulandı

Teklif öncesi doğrulayın

Mühendislik incelemesi

What to confirm before ordering this valve

The product name is not enough to release a valve for piping design or purchase. These five checks connect the catalog identity to the actual line interface, shutoff requirement and electric-actuator package.

Welded construction and line ends

Clarify whether “fully welded” describes the pressure-boundary body, the pipe ends or both. Obtain the offered GA and end-preparation drawing; match pipe outside diameter, wall thickness or schedule, bevel, material and overall dimensions. Include project welding, NDE and PWHT requirements where specified. The catalog word “Welded” does not by itself prove butt-weld ends.

Disc sweep and pipe clearance

Use the offered drawing’s full-open disc envelope and minimum upstream/downstream pipe inside diameter. Compare them with the actual bore after lining, weld-root intrusion, reducers, elbows, adjacent valves and other in-line equipment. Nominal line size alone cannot confirm that the disc clears throughout its travel.

Shutoff differential pressure and seat leakage

Provide normal, design and upset pressure cases, plus the maximum differential pressure across a closed valve in each required direction. Include reverse pressure, vacuum and surge where applicable. Identify the body-seat and disc seal-ring construction, material grades, pressure direction and replaceability. State the permitted leakage, test standard and edition, test medium, pressure and direction. “Metal-to-metal” does not guarantee zero leakage or bidirectional shutoff.

Electric actuator torque and controls

Request break-to-open, running, seating and unseating torque for the exact valve at the worst specified differential pressure, temperature, flow direction and flow condition. Disclose upstream pumps, check valves, elbows and reducers; disturbed approach flow can increase torque and vibration. Verify both sides of the actuator torque window. At the minimum specified supply voltage at the actuator terminals, confirm that available output meets the required valve torque under the specified worst-case duty. Separately confirm that the maximum available output at the upper specified supply-voltage tolerance, and the maximum configured torque-limit or stall output in each direction, do not exceed the valve manufacturer’s allowable stem, shaft and gearbox torque. Specify on/off or modulating duty, stroke time, cycles, feedback, local controls and the required response to power or signal loss.

Release documents and inspection

Request the coordinated valve/actuator GA and section drawings, valve and actuator datasheets, torque-selection basis, wiring/control diagram, applicable test and inspection records, material traceability and any project-required certificates or witness points. Confirm that the documents identify the same offered assembly and revision.

Uygulama sınırı

Service and installation conditions still govern selection

The catalog does not assign a medium or application to this entry. The service conditions below determine whether the offered materials, seat and installation arrangement are suitable.

Service medium and temperature

State fluid composition and phase, solids, abrasion, corrosion or erosion risk, cleaning conditions, and minimum, normal and maximum temperature. Use those inputs to confirm the body, disc, shaft and seat materials; do not infer material grades from the catalog photograph.

Isolation, throttling and cycling

Define whether the valve provides isolation, bypass or flow modulation, how often it cycles, and the consequence of leakage or failure. If intermediate positioning is required, obtain written confirmation of the permitted control range, flow conditions and actuator modulating duty. An electric-actuation label alone does not establish throttling suitability.

Montaj ve bakım zarfı

Confirm shaft orientation where specified by the offered design, piping loads, thermal movement, supports, actuator and manual-override access, cable routing, lifting space and maintenance clearance. If installed near pumps, check valves or elbows, request the manufacturer’s minimum upstream straight-run and shaft-orientation recommendations. For a welded installation, agree the welding and inspection sequence and how the seat and actuator can be accessed after installation.

Alıcı soruları

Questions to resolve before specification

The catalog confirms the product identity, but the offered drawing, datasheet and acceptance criteria determine whether the configuration fits the project.

Does “fully welded” confirm a butt-weld pipe connection?

No. The catalog uses “fully welded” in the product title and “Welded” in the connection field, but it does not define the line-end geometry or preparation. Confirm whether the wording refers to the valve body construction, the pipe ends or both on the offered GA and end-preparation drawing.

Does metal-to-metal mean zero leakage or bidirectional shutoff?

No. It is a catalog sealing description, not a leakage acceptance or pressure-direction rating. Obtain the offered seat/seal design, maximum shutoff differential pressure, required flow direction and the specified leakage test basis. Bidirectional shutoff and a zero-leakage claim are not established by the catalog label.

How should disc clearance be checked?

Use the offered full-open disc envelope and minimum pipe I.D. data. Compare them with the actual pipe bore, including lining and weld-root intrusion, plus reducers, mating components and nearby valves. A catalog photograph cannot establish the required clearance.

What actuator information is needed for an RFQ?

Provide the maximum differential pressure in each required direction, fluid and temperature, operating duty, site power and control requirements. Request breakaway, running, seating and unseating torque, actuator output/derating, stroke time, duty rating, feedback and the required response to power or signal loss.

Teknik talep

Request a matched valve and electric-actuator review

Reference catalog entity CCE-R2-0121 and provide the operating and piping data below. The supplier’s offer should identify the exact body/end design, seat and leakage basis, and matched electric actuator in coordinated drawings and datasheets. Unknown fields should remain open until documented—not assumed from the product title or images.

Fields marked * are required.