PDF belgeli ürün
Elektrikli Flanşlı Havalandırma Kelebek Valfi
Geri kazanılan İngilizce katalog, bu kalemi şu şekilde tanımlar: Elektrikli Flanşlı Havalandırma Kelebek Valfi on PDF page 99. It confirms a butterfly-valve type, electric actuation and a flanged connection, but does not publish the size, pressure or vacuum limits, materials, seat leakage, internal construction or actuator rating. Use the actual ventilation duty and mating-pipe details below to request a documented valve-and-actuator configuration. The catalog image is an identity reference, not a dimensional or performance drawing.
- Vana tipi: Kelebek Vana
- Aktüasyon: Elektrikli
- Bağlantı: Flanşlı
Ürün kimliği
Bu katalog kaydının tanımladıkları
Bu sayfa, belgelenmiş tek bir katalog kimliğini kapsar. Üst Kelebek Vanalar kategorisinin yerini almaz ve sipariş edilebilir bir boyut, basınç sınıfı, malzeme kalitesi, iç tasarım veya proje performansı ortaya koymaz. Bu detaylar, incelemeye sunulan tam konfigürasyona bağlanmalıdır.
Ürün ailesi
Kelebek Vana. Bu, kategori düzeyinde seçim için ana ticari yoldur.
Katalog serisi
Kelebek Vana. Bu, geri kazanılan ürün kataloğunda basılı kaynak seri bağlamıdır.
Kanıt kaynağı
Geri kazanılan İngilizce ürün kataloğu, PDF sayfa 99; eşleşen ürün görseli AST-R1-0317 (katalog belirteci 099_01).
Katalog kanıtı
Katalog belgeli ürün verileri
Aşağıda yalnızca geri kazanılan PDF kataloğunda belirtilen alanlar doğrulanmıştır. “Havalandırma”, katalog ürün adının bir parçasıdır; kayıt gerçek gaz bileşimini, tasarım basıncını, basınç farkını, sıcaklığı, debi aralığını veya gerekli sızdırma oranını tanımlamaz.
| Alan | Katalogda belgelenen değer | Kanıt durumu |
|---|---|---|
| Vana tipi | Kelebek Vana | DOĞRULANDI — PDF katalog etiketi |
| Aktüasyon | Elektrikli | DOĞRULANDI — PDF katalog etiketi |
| Bağlantı | Flanşlı | DOĞRULANDI — PDF katalog etiketi |
| Katalog kaynak serisi | Kelebek Vana | DOĞRULANDI — PDF katalog bölümü |
| Katalog kaynak sayfası | PDF sayfa 99 | DOĞRULANDI — kurtarılan PDF eşlemesi |
Önemli: bu tabloda gösterilmeyen değerler, ürün adı veya fotoğraftan çıkarılamaz. Bunları sunulan veri sayfası, vana-aktüatör listesi ve onaylı genel yerleşim (GA) çizimine göre doğrulayın.
Kanıt kapsamı
Doğrulanacak katalog bilgileri ve konfigürasyon kalemleri
Geri kazanılan katalog, ürün etiketini, elektrikli aktüasyonu ve flanşlı bağlantıyı doğrular. Siparişe hazır bir tasarım veya çalışma zarfı sunmaz. Vanayı yalnızca ürün adına veya görsele dayanarak değil; gerçek havalandırma ortamına, gerekli sızdırmaya, maksimum basınç farkına ve montaj geometrisine göre seçin.
Katalog tarafından doğrulandı
- Vana tipi: Kelebek Vana — katalog ürün etiketinde belirtilmiştir.
- Aktüasyon: Elektrikli — tahrik kategorisi belirtilmiştir; elektriksel sınıf ve kontroller belirtilmemiştir.
- Bağlantı: Flanşlı — bağlantı ailesi belirtilmiştir; flanş standardı ve ölçüleri belirtilmemiştir.
Teklif öncesi doğrulayın
- Servis: gerçek hava/gaz bileşimi, debi aralığı, toz, nem, kondens ve korozif bileşenler.
- Çalışma limitleri: minimum/normal/maksimum sıcaklık, tasarım basıncı, maksimum diferansiyel basınç, ters basınç ve varsa vakum veya geçici durum.
- Vana tasarımı: gövde, disk, mil ve oturma düzeni; malzeme kaliteleri; basınç-sıcaklık limitleri.
- Bağlantı: DN/NPS, flanş standardı ve delik düzeni, yüzey, yüz yüze ölçü, conta düzeni ve karşı boru iç çapı.
- Sızdırmazlık: gerekli sızıntı oranı veya sınıfı, test yöntemi ve izin verilen sızıntı yönü.
- Elektrikli aktüatör: besleme, kontrol modu, geri bildirim, strok süresi, çevrim yükü, tork esası ve güç/sinyal kaybına tepki.
- Dokümanlar: sunulan GA çizimi, veri sayfaları, bağlantı şeması ve proje gereksinimli muayene/test kayıtları.
Mühendislik incelemesi
Gerçek havalandırma görevi için vanayı ve elektrikli aktüatörü belirtin
Amaçlanan havalandırma servisi için önce vananın debiyi izole mi ettiğine yoksa düzenlediğine mi karar verin. Ardından disk üzerindeki diferansiyel basıncı, flanşlı montaj zarfını, gerekli oturma sızdırmazlığını ve aktüatör torkunu tek bir eşleşmiş düzenek olarak kontrol edin.
İzolasyon veya hava akışı kontrolü
Vananın tam açık/tam kapalı mı olduğunu yoksa hava akışını modüle etmesi mi gerektiğini, gerekli debi aralığı, çevrim sıklığı ve strok süresiyle birlikte belirtin. Modülasyon görevi için sunulan vananın akış karakteristiğini veya Cv data over the intended travel range and check pressure loss against the fan/system curve. A simple on/off actuator is not automatically suitable for frequent positioning.
Medium and operating envelope
Identify the nominal size and the required pressure designation: PN, ASME Class or project piping class, as applicable to the line specification. Describe the actual air or gas composition, normal and maximum flow, dust or particles, moisture/condensate and corrosive components. Provide minimum, normal and maximum temperature, operating/design pressure, maximum differential pressure across the disc during opening, closing and any intermediate positioning, reverse-pressure cases and any transient or vacuum condition. Include the fan shutoff condition where relevant. Line design pressure, the specified PN/Class or piping class, and the differential pressure used for actuator sizing are distinct inputs and must not be treated as interchangeable.
Flanged interface and disc clearance
“Flanged” does not specify the mating dimensions. Provide DN/NPS, flange standard, facing and drilling, bolt circle, face-to-face length, gasket opening and mating-pipe bore. Use the approved GA drawing to check the disc’s full swept envelope against the flange bore, gasket, liner, reducer, weld protrusions and adjacent fittings. Do not use the catalog photograph as a clearance drawing.
Seat sealing and leakage
State whether the requirement is isolation or throttling, the allowable leakage rate/class, test method and pressure direction. Ask the supplier to identify the body, disc, shaft, seat and seal materials and document their compatibility with the actual gas, temperature and differential pressure. Do not assume tight shutoff, bidirectional sealing or a particular seat design from the catalog name.
Electric actuator and release documents
Request breakaway, running, seating and any significant flow-induced dynamic torque for the specified valve at the maximum differential pressure and service temperature. Check actuator output at the minimum available site voltage and worst ambient condition against the required torque, and ensure its maximum output does not exceed the valve/shaft allowable torque. Confirm the mounting flange, drive coupling and travel stops. Specify supply voltage, phase and frequency; on/off or modulating duty; travel time; cycles/starts; command and feedback; local controls; enclosure/environment; and the separate required responses to power loss and signal loss. For purchase review, identify the required valve and actuator datasheets, GA and wiring drawings, material certificates and traceability records, marking requirements, pressure/leakage test scope and acceptance criteria, and any project-required inspection, witness or hold points. These are requirements to be stated and agreed for the order, not assumed standard inclusions or existing certifications. Electric actuation alone does not define a fail position.
Uygulama sınırı
Ventilation duty changes with the actual gas service
The catalog name points to ventilation service but does not identify the medium. Clean air, dust-laden process gas and hot or corrosive exhaust can impose different demands on the seat, materials, disc movement and actuator. Treat these as conditional service cases, not confirmed product ratings.
Clean air or HVAC duct
If the service is clean air or an HVAC duct, state the design airflow, fan operating point, temperature/humidity, allowable pressure drop and whether the valve isolates or modulates. For airflow control, require the exact valve’s flow characteristic and an actuator rated for the specified positioning duty; the catalog entry supplies neither a Cv curve nor a velocity limit.
Dust-laden or wet gas
If the gas carries dust, fibers, deposits or condensate, provide the particle type/loading, expected build-up, moisture and cleaning method. Ask how the offered disc, seat and shaft arrangement addresses fouling and whether inspection access is available. Deposits and fibrous media can affect disc movement and operating torque.
Hot or corrosive exhaust
For installation and maintenance review, provide the proposed mounting orientation and flow direction, the relevant piping loads or duct loads at the valve, the available space around the body and actuator, and the access needed for inspection, removal and maintenance. Include the site layout and mating-interface details so the supplier can check actuator and accessory clearance and the maintenance envelope. Orientation and flow direction must be confirmed for the offered design and service; neither is assumed to be universally required.
If the exhaust is hot, humid or corrosive, also provide the gas composition, corrosive constituents, condensate chemistry and minimum/maximum temperature. Require the supplier to identify the body, disc, shaft, seat and seal materials and their pressure-temperature limits for the exact assembly; the catalog image and name do not establish material grades or a temperature rating.
İlgili ürün rotaları
Related butterfly valve records
These are separate catalog identities, not alternate configurations of this ventilation valve. Use the parent Butterfly Valves category for broader family selection; review each linked record on its own evidence and do not transfer its specifications to this product.
Elektrikli Kelebek Valf
Review this separate electric-actuated butterfly valve record for its own catalog identity and configuration questions. It does not establish the dimensions, materials or actuator specification of the ventilation valve on this page.
Büyük Çaplı Flanşlı Kelebek Vana
Use this separate record when large-diameter flanged geometry is the comparison point. Its dimensions and operating limits must not be carried over to this product.
Boru Hattı Kelebek Vana
Review this separate pipe-network butterfly valve identity for its own connection and operating data. A network application label does not establish suitability for ventilation gas service.
Alıcı soruları
Electric Flanged Ventilation Butterfly Valve FAQ
These answers separate the recovered catalog facts from the engineering data required for a quotation.
What does the catalog confirm for this product?
It identifies the product as an Electric Flanged Ventilation Butterfly Valve in the Butterfly Valve series. The catalog confirms electric actuation and a flanged connection on PDF page 99; it does not publish a complete model or operating specification.
Does the catalog specify the valve size, pressure rating or seat design?
No. Size, pressure and vacuum limits, pressure-temperature envelope, internal construction, material grades, seat design and leakage performance are not established by the catalog entry. Request the offered datasheet, material schedule and approved GA drawing.
How should the flanged connection and disc clearance be checked?
Match the nominal size, flange standard and drilling, facing, face-to-face length, gasket opening and pipe bore. Then check the disc’s full travel envelope against the mating flange, gasket, liner, reducer and adjacent fittings using the approved dimensional drawing. The catalog photograph is not a dimensional reference.
What information is needed to size the electric actuator?
Provide the maximum differential pressure across the disc, service medium and temperature, required leakage, operating duty, travel time and cycle rate. Request the valve’s breakaway, running, seating and dynamic torque data, the allowable shaft torque, actuator supply and output, control/feedback requirements and response to power or signal loss.
Teknik talep
Konfigürasyon incelemesi talep edin
Reference this catalog identity and include the quantity, nominal size, required PN/Class or project piping class (where specified), service and operating/design conditions, maximum differential pressure, duty and required leakage in your inquiry. List the documents and quality records required for purchase release, including applicable datasheets, GA/wiring drawings, material certificates and traceability, marking, pressure/leakage tests, inspection, witness and hold points. VALMORA can review the proposed valve/actuator combination, flange interface, seat requirements and document scope. Any rating, option, test, certificate or performance not stated in the catalog must be identified and confirmed in the supplier’s written offer.
- Service: gas composition, flow range, temperature, dust/moisture and corrosion conditions
- Duty: isolation or modulation, cycle rate, required leakage and pressure direction
- Line: DN/NPS, flange standard/drilling, face-to-face, gasket and pipe-bore details
- Pressure: operating/design pressure, maximum differential, reverse/transient or vacuum cases
- Electric drive: supply, controls/feedback, travel time, fail response and required drawings/tests