Produit documenté au format PDF
Pneumatic Stainless Steel High Temperature Flanged Butterfly Valve
Le catalogue fournisseur identifie cet article comme Pneumatic Stainless Steel High Temperature Flanged Butterfly Valve on PDF page 95. The catalog confirms the product label and appearance only; it does not publish a numerical process-temperature limit, pressure-temperature curve, seat material or actuator ambient rating. Use the catalog identity to start the review, then verify the offered valve and actuator package against the actual duty.
- Type de vanne : vanne papillon
- Descripteur de matériau : acier inoxydable
- Actionnement : pneumatique
- Raccordement : à brides
Identification du produit
Ce que la fiche catalogue identifie
Cette page représente une identité de catalogue documentée. Elle ne remplace pas la catégorie de produit parente et ne revendique ni modèle, ni classement, ni historique de projet non vérifié.
Famille de produits
Vanne papillon. Il s'agit de la route commerciale parente pour la sélection au niveau de la catégorie.
Série de catalogue
Vanne papillon. Il s'agit du contexte de série source imprimé dans le catalogue produit récupéré.
Source des éléments
Recovered supplier English product catalog, PDF page 95; mapped product image AST-R1-0305.
Éléments du catalogue
Données produit documentées au catalogue
Seuls les champs indiqués par l'étiquette du catalogue PDF sont présentés comme données produit. Un terme descriptif tel que haute pression, grand diamètre ou ASME ne crée ni une classe de pression numérique, ni une plage de commande, ni une allégation de certification.
| Champ | Valeur documentée au catalogue | Statut de la preuve |
|---|---|---|
| Type de robinet | Vanne papillon | VÉRIFIÉ — étiquette du catalogue PDF |
| Descriptif matière | Acier inoxydable | VÉRIFIÉ — étiquette du catalogue PDF |
| Actionnement | Pneumatique | VÉRIFIÉ — étiquette du catalogue PDF |
| Raccordement | À brides | VÉRIFIÉ — étiquette du catalogue PDF |
| Série source du catalogue | Vanne papillon | VÉRIFIÉ — section du catalogue PDF |
| Page source du catalogue | Page 95 du PDF | VÉRIFIÉ — correspondance PDF récupérée |
Important : The catalog name includes “High Temperature,” but this record gives no numerical process-temperature limit or pressure-temperature curve. Confirm the offered body, seat, seals and actuator package against the project duty and the approved datasheet and order drawing.
Revue d'ingénierie
What must match before the valve and actuator are specified
For high-temperature service, check the process limits at the valve separately from the temperature around the actuator. The five checks below turn the catalog identity into a configuration that can be evaluated against the real duty.
Process duty and operating envelope
Define the duty—on/off isolation, throttling, bypass or another function—together with medium composition and phase, solids, corrosion or erosion risk, cycle frequency and required shutoff. Provide minimum, normal and maximum process temperature, design and operating pressure, maximum differential pressure, and any start-up, upset or vacuum case. Ask for the allowable pressure at the maximum temperature for the exact offered valve; the catalog name does not define this envelope.
Seat, trim and leakage
Confirm the exact body and disc/shaft grades, seat construction and material, packing, and body seals. “Stainless steel” in the catalog title is not a grade or a complete wetted-parts schedule. Soft and metal seats have different temperature limits, leakage behavior and operating torque; do not assume either from the product name or image. Require the seat and body pressure-temperature limits plus the specified leakage class and direction for the service.
Flanged fit-up and disc clearance
Confirm nominal size, flange standard and pressure designation, facing, bolt pattern, face-to-face dimension, and the gasket arrangement specified for the valve design. Check the mating pipe and flange bore against the disc sweep through full travel, including any liner, reducer or adjacent equipment. Where required by the valve design or service, state the installation orientation and flow direction; provide the expected piping loads at the valve and the available space for actuator access, removal and routine valve maintenance. Have allowable external loads and service clearances confirmed on the approved dimension drawing before ordering.
Actuator temperature and heat path
Do not equate process temperature at the valve with the allowable ambient temperature at the actuator. Record the maximum temperature around the actuator and its solenoid, positioner, limit switches and tubing. Heat may reach the mounting area through the valve body, neck and stem, as well as by radiation or hot surroundings. Ask the supplier whether an approved stem extension, thermal spacer, heat shield or remote mounting is required, and have the arrangement and limits shown on the assembly drawing. The catalog image does not establish thermal isolation.
Pneumatic sizing and air-failure response
Choose double-acting or spring-return actuation to meet the required response on loss of instrument air. State fail-open, fail-closed or fail-in-place behavior separately for air loss, electrical-power loss and control-signal loss; these are not automatically the same event. Confirm minimum and maximum available air pressure. At minimum supply pressure, the actuator must provide the required torque at maximum differential pressure and service temperature; at maximum supply pressure, its output must remain within the valve and shaft allowable torque. Also confirm travel time and cycle rate. Specify the solenoid-valve coil voltage and the electrical command/interface required by the control system. State whether open/closed limit switches and/or position feedback are required, including the required feedback type and interface, and confirm which accessories are included in the offered package. For modulating or throttling duty, state whether a positioner or another supplier-reviewed proportional-control arrangement is required; if so, identify the required control input and interface for supplier review. Do not assume a positioner is needed for on/off service or included in the standard package. A double-acting actuator alone has no inherent spring-driven fail position; any stored-air or lock-up arrangement must be specified and verified for the required response.
Gammes de produits associées
Comparez les alternatives documentées avant la demande de devis
These are separate catalog records, not interchangeable configurations. Open each product record for its own identity and documentation; no material, temperature limit, actuator behavior or dimensional data transfers from this page.
Vanne papillon électrique
A separate electric-actuation catalog entry. Review its own actuator, power and control requirements rather than transferring the pneumatic package assumptions from this page.
Vanne papillon à brides de grand diamètre
A separate flanged catalog entry. Its own size, pressure-temperature envelope and mating-flange drawing must be checked for the project.
Vanne papillon pour réseau de tuyauterie
A separate pipeline-network catalog entry. Confirm its own construction, connection and service limits before treating it as an alternative.
Questions des acheteurs
High-temperature butterfly valve: buyer questions
These points resolve the main gaps between a catalog name and an order-ready valve assembly.
What does “High Temperature” confirm?
No numerical limit. It is part of the supplier catalog name. The recovered catalog record on PDF page 95 does not state a process-temperature limit, pressure-temperature curve or exact seat material. Obtain the model-specific datasheet and confirm pressure and temperature together for the offered body, trim and seat.
Are the valve and actuator temperature limits the same?
No. Process temperature applies to the valve’s wetted and pressure-containing components; the actuator and its accessories have their own operating and ambient limits. Check the temperature at the actuator location and heat transfer from the valve. Any extension, spacer or heat shield must be approved for the exact assembly.
Does pneumatic actuation define the fail position?
No. The catalog identifies pneumatic actuation but does not state whether the actuator is double-acting or spring-return, or what position it takes on air loss. Specify the required response to loss of instrument air, electrical power and control signal, then confirm the actuator and control circuit that provide it.
What must be checked at the mating flanges?
Provide the nominal size, flange standard and pressure designation, facing, bolt pattern, face-to-face dimension and valve-specified gasket arrangement. The pipe and flange bore must leave room for the disc throughout full travel. Confirm the fit against the approved dimension drawing.
Demande technique
Demander une revue de configuration
Use this inquiry to identify the exact offered assembly. Request a model-specific datasheet and dimension drawing showing the valve pressure-temperature envelope, seat and sealing materials, actuator temperature limits, mounting arrangement, fail response and flange interface. See VALMORA Valve Resources & Technical Document Support for the process to request datasheets, drawings and IOM files. The catalog label alone is not a technical approval for the duty.
- Valve function, medium composition and phase, solids and corrosion risks
- DN/NPS, design and operating pressure, maximum differential pressure, and process temperature range
- Body, disc, shaft, seat, packing and seal materials; required leakage class and direction
- Mating flange standard, pressure designation, facing, drilling, face-to-face dimension and gasket arrangement
- Actuator type, minimum and maximum air pressure, fail response to air/power/signal loss, torque output and limits, travel time, solenoid-valve coil voltage and electrical command/interface, and limit-switch/position-feedback requirements. For modulating/throttling duty, confirm whether a positioner or another supplier-reviewed proportional-control arrangement is required. If so, specify the control input/interface and ask the supplier to confirm suitability and included scope. Do not assume this is required for on/off duty.
- Maximum ambient temperature at actuator/accessories, quantity, drawings, material/test records and inspection requirements
- Project-specified valve design and test standards, including the required edition/year, where applicable
- Installation orientation and flow direction where design-dependent; expected piping loads at the valve; actuator access/removal space and maintenance envelope
