BWA42Y · PDF-documented product
Полноподъемный предохранительно-сбросной клапан с рубашкой обогрева, уравновешенный по противодавлению
В восстановленном английском каталоге указано BWA42Y as the Полноподъемный предохранительно-сбросной клапан с рубашкой обогрева, уравновешенный по противодавлению on PDF page 106. The designation and design descriptors identify the catalog record; set pressure, relieving capacity, back-pressure limits and jacket details must be confirmed for the offered configuration.
- Catalog designation: BWA42Y (as printed on PDF page 106)
- Catalog descriptors: insulated jacket; back-pressure balanced; full-lift
Идентификация в каталоге
BWA42Y in the Safety Valve series
The English catalog prints “BWA42Y” beside this product name on PDF page 106. It appears in the Safety/Relief Valve family under the Safety Valve series. Treat BWA42Y as the catalog designation until the offered datasheet and order drawing confirm the exact model and revision.
Обозначение по каталогу
BWA42Y, as printed in the recovered English product catalog. Confirm the offered model code and revision against the current datasheet and approved drawing.
Семейство изделий
Safety/Relief Valve. The parent category remains the route for browsing the wider safety and relief valve range.
Catalog series and image source
Safety Valve series; recovered English product catalog, PDF page 106.
Данные каталога
Что фактически указано в каталоге
The product label names three design descriptors—insulated jacket, back-pressure balanced and full-lift. These words identify the catalog configuration but do not provide numeric performance limits or prove a specific internal balance mechanism.
| Поле | Значение по каталогу | Статус подтверждения |
|---|---|---|
| Обозначение по каталогу | BWA42Y | VERIFIED — printed in the PDF product label |
| Named design descriptors | Insulated jacket; back-pressure balanced; full-lift | VERIFIED — catalog product name only |
| Источник каталога | Safety Valve series; recovered English product catalog, PDF page 106 | VERIFIED — catalog page and product-image mapping |
Важно: the supplied page-106 evidence does not state set pressure, rated relieving capacity, orifice, nominal size, pressure class, temperature range, material grades, end connections or approvals. Obtain these from the offered datasheet and approved order drawing.
Граница подтверждаемых данных
Performance and construction still need proof
The catalog record establishes the name and identity, not an order-ready pressure-relief device. Keep the relief-duty basis separate from the jacket and mechanical construction details.
Relief performance
- Set pressure, adjustment range, rated relieving capacity value (mass or volumetric flow, with units) and orifice
- Allowable accumulation during relieving above the protected equipment's MAWP (or applicable design pressure limit); allowable overpressure at the valve inlet above the valve's set pressure; pressure-temperature limits and capacity certification basis
Jacket and offered construction
- Superimposed constant/variable and built-up back-pressure limits
- Jacket type (passive or heated); if heated, medium, design pressure/temperature, connections and coverage
- Body, trim, seat/seal and any balance-element material grades
- Nominal size, end connections, dimensions, governing code/edition, approvals and inspection/test records
Техническая экспертиза
Build the RFQ around the relief duty
A safety relief valve is sized for a defined overpressure case, not selected from its product name or inlet size alone. The protected equipment, relieving scenario and fluid properties establish the duty; the discharge system and jacket arrangement determine whether this catalog configuration can be offered for it.
Защищаемое оборудование и сценарий сброса
Identify the protected vessel, line or equipment; provide its MAWP or governing design limit, credible overpressure scenarios, and the required relieving mass flow or volumetric flow with its value and unit. State the corresponding relieving pressure and temperature, fluid phase at relief—gas/vapor, liquid or two-phase—relevant fluid properties, and the sizing calculation basis.
Set pressure and inlet conditions
Provide normal operating pressure, proposed valve set pressure, relieving pressure and temperature, allowable accumulation during relieving above the protected equipment's MAWP (or applicable design pressure limit), and allowable overpressure at the valve inlet above the valve's set pressure. State the governing code/design basis and the pressure reference used for each limit, plus inlet pressure loss. The catalog does not state a set-pressure range or rated capacity.
Back-pressure profile and discharge header
Separate superimposed constant back pressure, superimposed variable back pressure and built-up back pressure at the required relieving flow. Identify common headers and other devices that may discharge simultaneously. Ask the supplier to state the allowable limit and any effect on set pressure, lift and capacity for the offered construction.
Jacket and thermal duty
Clarify whether “insulated jacket” means passive insulation or a heated cavity. If heated, state the available utility, supply/return pressure and temperature, jacket connection arrangement, coverage, vent/drain needs and separate jacket design/test basis. Confirm whether adjacent inlet/outlet piping also needs heat tracing.
Fluid, materials and project documents
Give fluid composition, concentration, phase, viscosity, solids, crystallization/solidification and corrosion/erosion risks. Confirm body, trim, seat/seal and any balance-element materials, size and end connections, governing code/edition, jurisdiction, approval scope, tests, inspection and witness requirements.
Границы применения
Three decisions the catalog name does not settle
The name points to a jacketed, back-pressure-balanced, full-lift configuration. It does not establish the actual service limits. Use these distinctions to prepare the technical review.
Does the jacket add heat or only slow heat loss?
If the process medium becomes viscous, crystallizes or deposits as it cools, a heated jacket may help maintain the flow path. Passive insulation only slows heat loss; it does not supply heat. Confirm the supplied arrangement, heated zones, utility and separate jacket rating. Do not assume the seat, nozzle or adjoining piping is heated because the catalog uses “insulated jacket.”
What kind of back pressure will the outlet see?
Superimposed back pressure exists before the valve opens; built-up back pressure develops as relieving flow passes through the discharge piping. Variable pressure from a common header is different from a steady outlet pressure. A balanced design may reduce the effect of back pressure, but it is not unlimited; the supplier must confirm the mechanism, allowable pressure and performance for the actual duty. If bellows are used, also confirm bellows material/limit and bonnet-vent arrangement.
Does full-lift establish a capacity?
No. “Full-lift” is a catalog design descriptor, not a rated relieving-capacity figure or certified flow coefficient. Capacity depends on the offered orifice and valve construction plus fluid phase/properties, set pressure, overpressure, temperature and back pressure. Use the manufacturer’s sizing and certification documents for the selected tag.
Визуальные материалы
Catalog image for BWA42Y
The recovered English catalog on PDF page 106 pairs the BWA42Y product label with this image. This image confirms catalog identity and visible appearance only; it is not a dimensional drawing or evidence of material, rating, capacity, certification or supplied options.
Связанные позиции каталога
Other safety-relief product identities
These linked pages are separate catalog records, not proven drop-in alternatives. Compare each model against its own datasheet, relief duty and approval scope before treating it as a substitute.
Предохранительно-сбросной клапан A48SY-P
A separate A48SY-P catalog record. Check its own datasheet, sizing basis and approval scope; no BWA42Y values transfer.
Предохранительно-сбросной клапан A48SY-V
A separate A48SY-V catalog record. Check its own datasheet, sizing basis and approval scope; no BWA42Y values transfer.
Предохранительно-сбросной клапан A42Y
A separate A42Y catalog record. Confirm its own construction, materials and relief duty before considering it as an alternative.
Подтверждение поставщика
What the quotation should document
The catalog label is not enough for technical approval. Review the offer against the same relief case and require the following details in the supplier’s return package.
Model and jacket construction
Confirm the BWA42Y designation and revision, the actual back-pressure balancing mechanism, and whether the jacket is passive insulation or a heated cavity. The datasheet and drawing should identify jacket coverage, connection locations and any heating medium. Do not assume bellows unless the offered drawing identifies them.
Relief performance and sizing basis
The return package should state the offered set pressure and orifice; rated relieving capacity value with its mass- or volumetric-flow unit, applicable fluid phase/properties and relieving conditions; and the sizing/certification basis. It should separately identify allowable accumulation during relieving above the protected equipment's MAWP (or applicable design pressure limit) and allowable overpressure at the valve inlet above the valve's set pressure, plus allowable back pressure for the specified relieving case. Do not substitute values from another model or series.
Materials and pressure boundaries
Confirm process-side body, trim, seat/seal and balance-element materials, pressure-temperature limits, end connections and dimensions. If the jacket is a heated cavity, provide its separate design pressure/temperature, test basis, utility and drainage/vent details.
Code, approvals and inspection records
Identify the governing code and edition, jurisdiction, certificate or stamp and approval scope for this exact model/tag. List the required pressure/leakage tests, inspection reports, witness points and marking; availability and applicability must be stated in the quotation.
Технический запрос
Request a BWA42Y configuration review
Reference catalog designation BWA42Y and provide the known relief-duty and jacket data. Mark unknown values as pending; do not estimate set pressure, capacity, back-pressure limits or certification. The existing product inquiry form remains the submission route.
- Protected equipment, MAWP/design limit, credible relieving scenario(s), and required mass or volumetric relieving flow value with units and sizing calculation basis
- Normal operating pressure/temperature, proposed set pressure, relieving pressure/temperature, allowable accumulation during relieving above the protected equipment's MAWP (or applicable design pressure limit), and allowable overpressure at the valve inlet above the valve's set pressure
- Fluid composition/phase, concentration, relevant properties, solids and corrosion/erosion risks
- Superimposed constant/variable and built-up back pressure, discharge header and inlet pressure loss
- Nominal size, inlet/outlet connections, materials, jacket type and (if heated) utility, governing code/edition, approvals, tests, inspection and quantity