Supplier-catalog product record
صمام أمان وتنفيس ضغط من الفولاذ المطروق يعمل بالبايلوت
The published Lianggong supplier catalog identifies this item as a صمام أمان وتنفيس ضغط من الفولاذ المطروق يعمل بالبايلوت on PDF page 106. The catalog confirms the identity and descriptors shown below, but it does not provide an order-ready specification, set-pressure range, rated relieving capacity or certification.
- نوع الصمام: صمام أمان وتنفيس ضغط
- Design / construction: Pilot-operated
- وصف المادة: فولاذ مطروق
هوية المنتج
Where this product page fits
The parent category is the range-level navigation point; this page records one supplier-catalog product identity. It is not a complete datasheet and does not establish that another safety valve model is interchangeable.
أدلة الكتالوج
بيانات منتج موثّقة في الكتالوج
Only attributes stated in the supplier catalog are listed as product data. Product wording or visible markings in a catalog image do not establish a numeric set pressure, rated capacity, size range, pressure-temperature limit or code approval.
| الحقل | قيمة موثقة في الكتالوج | حالة الإثبات |
|---|---|---|
| نوع الصمام | صمام أمان وتنفيس ضغط | مُتحقق منه — تسمية كتالوج PDF |
| التصميم / الإنشاء | يعمل بالبايلوت | مُتحقق منه — تسمية كتالوج PDF |
| وصف المادة | فولاذ مطروق | مُتحقق منه — تسمية كتالوج PDF |
| سلسلة مصدر الكتالوج | صمام أمان | مُتحقق منه — قسم كتالوج PDF |
| صفحة مصدر الكتالوج | صفحة PDF 106 | مُتحقَّق منه — تم استرداد تعيين PDF |
هام: Unlisted values remain unconfirmed. Before sizing, installation or order release, obtain the datasheet, rated-capacity evidence and approved drawing for the exact offered configuration.
حدود الأدلة
ما لا يثبته سجل الكتالوج هذا
The catalog confirms product identity and mapped appearance only. It does not establish the exact model, nominal size, set pressure, rated relieving capacity, allowable back pressure, material grades, pressure-temperature limits or approval scope for a supplied unit.
غير محدد في الكتالوج
- Set pressure, rated relieving capacity or allowable back pressure
- Exact model, size, material grades, dimensions or pressure-temperature envelope
- Applicable code compliance, approval, certificate or test record for the offered unit
Supplier confirmation required
- Exact offered model, nominal size, inlet/outlet ends and dimensional standard
- Set pressure, rated capacity and allowable accumulation/overpressure for the stated relieving case
- Pilot type/action and sensing arrangement; whether the offered pilot is balanced or unbalanced; its exhaust route/connection arrangement; and the allowable pilot-exhaust back-pressure limit and any configuration restrictions for the exact offered model
- Body, trim, seat/seal and wetted-part grades, plus temperature and pressure-temperature limits
- Applicable code/jurisdiction, required marking or approval, and unit-specific certificate/test documents
مراجعة هندسية
ما يجب تقديمه لمراجعة التهيئة
The buyer defines the protection duty; the supplier must demonstrate that the proposed valve and pilot arrangement match it. A catalog identity alone cannot establish an orderable or certified selection.
Relieving duty and set pressure
Identify the protected equipment and its MAWP or governing design limit, credible relieving scenario(s), required relieving rate with units and calculation basis, proposed set pressure, and applicable accumulation/overpressure basis. Normal operating pressure is not a substitute for the required set pressure or capacity.
Operating envelope and connections
Provide normal, design and relieving pressure/temperature cases; nominal inlet and outlet size; end connection, rating designation and dimensional standard; inlet pressure loss; and any transient, vacuum or upset condition relevant to the relief case. The supplier must confirm the exact rating and pressure-temperature limits.
Fluid and material compatibility
State fluid composition, phase and relevant properties at relieving conditions. Flag solids, fouling, polymerizing or solidifying deposits, corrosion and erosion risks. Confirm body, trim, seat/seal and wetted-part grades against the actual medium, including any required corrosion allowance; “forged steel” is not a complete material specification.
Back pressure and pilot circuit
Keep main-valve outlet back pressure separate from pressure at the pilot-exhaust connection. For the main valve, provide minimum and maximum superimposed outlet back pressure and expected built-up outlet back pressure during relief, including common-header or simultaneous-relief cases, and identify the main discharge destination. Separately state whether the pilot exhaust will vent to atmosphere, connect to the main discharge header, or route to another closed or pressurized system. If the pilot exhaust connects to a closed or pressurized system, provide the expected pressure at that pilot-exhaust tie-in. Ask the supplier to confirm whether the offered pilot is balanced or unbalanced, the allowable pilot-exhaust back-pressure limit for the exact model/configuration, and any related operating restrictions. Do not assume pilot-exhaust pressure is the same as main-valve outlet back pressure. Also confirm mounting orientation, flow direction, inlet/outlet piping loads and supports, ambient exposure, available envelope and maintenance access against the approved drawing or IOM. Pilot operation alone does not prove immunity to back pressure.
Approvals and order documents
State the governing code, jurisdiction, required designation or certificate, and inspection/witness requirements. Request the offered datasheet, approved general-arrangement (GA) or dimensional drawing, rated or certified capacity evidence, material records, pressure/leakage test and inspection documents. Confirm the certificate holder and scope for the exact offered model; no approval is established by the catalog label.
مسارات المنتجات ذات الصلة
Other Safety/Relief Valve catalog records
These are separate product identities within the same category, not confirmed equivalents to this pilot-operated design. Open each record and review its own catalog evidence and supplier-confirmed configuration.
صمام أمان وتنفيس ضغط A48SY-P
سجل كتالوج آخر لصمام أمان/تنفيس موثق في PDF. راجع أدلته الخاصة وحدود تكوينه.
صمام أمان وتنفيس ضغط A48SY-V
سجل كتالوج آخر لصمام أمان/تنفيس موثق في PDF. راجع أدلته الخاصة وحدود تكوينه.
صمام أمان وتنفيس ضغط A42Y
سجل كتالوج آخر لصمام أمان/تنفيس موثق في PDF. راجع أدلته الخاصة وحدود تكوينه.
أسئلة المشترين
Forged Steel Pilot-Operated Safety Relief Valve FAQ
These answers distinguish what the supplier catalog identifies from what the project basis and offered-valve documents must establish.
What does the supplier catalog confirm?
It identifies this item as Forged Steel Pilot-Operated Safety Relief Valve in the Safety Valve series and supports the catalog descriptors shown in the table: Safety/Relief Valve, Pilot-operated and Forged steel. It does not provide an order-ready specification.
Does pilot-operated construction confirm back-pressure tolerance or relieving capacity?
No. “Pilot-operated” does not identify the pilot design or establish a back-pressure limit or rated relieving capacity. Provide the minimum/maximum superimposed and expected built-up main-valve outlet back-pressure cases separately from the pilot-exhaust destination. State whether the pilot exhaust will vent to atmosphere, join the main discharge header, or enter another closed or pressurized system; if it connects to a closed or pressurized system, provide the expected pressure at the pilot-exhaust tie-in. Ask the supplier to confirm whether the offered pilot is balanced or unbalanced and provide the allowable pilot-exhaust back-pressure limit and capacity evidence for the exact model/configuration.
ما الذي يجب تضمينه في طلب عرض السعر؟
Provide the protected equipment and credible relieving case, required capacity basis, set pressure and accumulation/overpressure basis, fluid composition and phase, normal/design/relieving pressure and temperature, and inlet/outlet connections. State the minimum/maximum superimposed and expected built-up main-valve outlet back-pressure cases and the main discharge destination. Separately identify the pilot-exhaust destination—atmosphere, main discharge header or another closed or pressurized system—and the expected pressure at the pilot-exhaust tie-in if the connection is closed or pressurized. Request supplier confirmation of the offered pilot type/action, sensing arrangement, whether it is balanced or unbalanced, and the model-specific allowable pilot-exhaust back-pressure limit. Include the governing code/jurisdiction, quantity and required documents.
Can the catalog image be used as a dimensional or approval reference?
No. It supports product identity and external appearance only. Use the offered datasheet, approved dimensional/order drawing and unit-specific capacity, material, test and approval records for sizing, installation and order review.
استفسار فني
Request a configuration review for Forged Steel Pilot-Operated Safety Relief Valve
Reference this catalog identity and provide the protection basis and project requirements. Unknown fields can remain marked for supplier confirmation; no unverified setting, capacity or code approval is assumed.
- Protected equipment, MAWP/design limit, credible relieving scenarios and required capacity with units and calculation basis
- Set pressure, normal/design/relieving pressure and temperature, and allowable accumulation/overpressure basis
- Fluid composition, phase and relevant properties at relieving conditions, including solids, fouling and corrosion risks
- Inlet/outlet size and connection, inlet loss, minimum and maximum superimposed main-valve outlet back-pressure cases, expected built-up main-valve outlet back pressure, and main discharge destination
- Pilot-exhaust destination (atmosphere, main discharge header, or a separate closed or pressurized system); if the connection is closed or pressurized, expected pressure at the pilot-exhaust tie-in; any remote-sensing, backflow or field-test requirements for supplier confirmation
- Mounting orientation, flow direction, piping loads/supports, ambient exposure, available envelope and maintenance access
- Governing code/jurisdiction, required approvals/certificates, drawing, datasheet, material/test/inspection records, quantity, delivery destination and requested schedule; supplier to confirm price and lead time